Example SET PRN REL COUNT 1
Sets the Smart Relay counter (collation) to one. For more information about the counter, see “About the Smart Relay Counter.”
Example SET PRN REL POS 10 5
Sets the Smart Relay counter (collation) field position on the label to 10 (for the row) and 5 (for the column).
The usable maximum values are dependent on printhead density (203 dpi or 300 dpi). The maximum label size is four inches wide by eight inches tall.
Printhead Density | Row | Column | |
203 | 0 | ||
300 | 0 |
Note: The Smart Relay Counter Field overwrites any format data in the same location. Make sure your format is designed with the Smart Relay Counter Field’s height and width in mind, so data is not overwritten.
A b o u t t h e S m a r t R e l a y C o u n t e r
The Smart Relay counter keeps your batches in order. Use the collation number to put printed labels back into the order they were sent to the primary printer. To use the Smart Relay counter, enable the counter and then set the row and column positions.
The collation number prints on each batch printed on both the primary and partner printers. Batches are numbered in the order they are received, not in the order they are printed. The collation number refers to the batch, not the individual labels in a batch. For example, a batch of ten labels would have the same collation number on them, so they could be kept together. We recommend only sending batches of one.
Using the Smart Relay System