Problem | Probable Cause | Corrective Action |
Front panel does not complete diagnostics test 2.
1)One or more PC board(s) unplugged from the Mother Board.
1)Power off and remove the power cord from the AC entry. Remove the back cover and reseat the offending board.
2) Relay unplugged or faulty.
2)Power off and remove the power cord from the AC entry. Remove the back cover and inspect the cables and connectors to and from the relay. Refer to the "Electrical System Schematic" and "Relay Assembly".
3) PCMCIA cartridge not inserted | 3) Insert a PCMCIA cartridge with |
correctly in optional PCMCIA | the arrow up and towards the front |
slot. | of the machine so that the ejector |
| button pops out. |
Machine does not receive batches.
1) | Serial communications cable loose | 1) | Check and secure both ends of the |
| or unconnected. |
| serial cable with the thumbscrews. |
|
|
|
|
2) | Machine not powered on or has | 2) | Power machine on and wait until |
| not completed diagnostics tests. |
| machine displays "Ready for |
|
|
| batches". Re download data. |
|
|
| |
3) | Data sent to wrong printer. | 3) In PCMate change to the printer | |
|
|
| the data is intended to be sent. |
4) | Configuration incorrect in | 4) | Re configure PCMate for Paxar |
| PCMate. |
| PCL printer as per your PCMate |
|
|
| manual. |
|
|
|
|
5) | Faulty Thermal Control Board. | 5) | Replace Thermal Control Board. |
|
|
|
|
6) | Jumpers not configured correctly. | 6) | Contact Paxar Service. |
46 • Electrical Trouble Shooting | Users Manual Model 656/636 |