15 - iRIS 220 / iRIS 320, V1.19 User Guide

3.4.2 Internal / External 12V Battery Supply

For all models there are two terminals provided on the I/O connector designated +12V and GND (or –12V on old models). These can be used to power the unit from an external 12V battery or regulated dc supply. For the iRIS 320 / iRIS 320V models, the internal battery is effectively connected directly to these terminals. See Section 3.4.1 for warnings on connecting external power supplies to them.

3.4.3 External (Charger) Power Supply

Although the iRIS 320 can operate solely from its internal battery for a few days, you will typically need to connect an external supply to the unit so that the internal battery remains in a charged state. You can connect any external dc power source ranging from 15 – 30Vdc, including a solar panel, without requiring an additional solar regulator.

The battery charging circuitry utilises a switch mode regulator for maximum efficiency. The external power supply is protected against over-voltage by ultra-fast acting protection devices and a self-resetting semiconductor fuse.

It can also be used to charge an external battery connected to the GND and 12V+ terminals. In the event that the external battery draws excessive current, the charger will enter a current limit mode (900mA) until such time as the battery has been recharged sufficiently to deliver the full supply voltage. The charging profile used by the charger depends on the selected mode. See the Power Management description in Section 4.3.1.

3.4.4 Analog Inputs

The four analogue inputs are uni-polar 0-5Vdc with 12-bit resolution. Each input presents a load impedance of 98KΩ to the input signal.

Scaling factors should be chosen to convert from a raw value of 0-5000, which reflects the input signal range of 0-5V (0-5000mV). When current sources such as 0-20mA or 4-20mA are used, an external sink resistor (typically 250Ω) must be fitted between the analogue input and AGND.

NOTE: As the analogue inputs have an input impedance of 98KΩ, the actual sink impedance will be slightly lower than the value fitted. For example, a sink resistor of 250 ohms is installed. The actual impedance will theoretically be 249.36Ω; therefore the voltage measured by the iRIS will also be slightly lower than expected.

AINx

51K

47K

To ADC

100nF

AGND

Figure 5 - Analog Input Circuit

Image 17
Contents IRIS 220 iRIS Revision History Contents Diagnostic LEDs 13.2 13.113.3 13.4About this Manual IntroductionHardware PCB Revision SupportIntroduction General Characteristics iRISOverview IRIS 320 / iRIS Typical Applications FeaturesFeature Summary Technical Specifications iRIS Technical Specifications iRIS 320 / iRIS Terminal Configuration Key FeaturesWireless IP Connectivity GPRS/CDMA Alternative Wireless Connectivity CSD/SMSData Logging Partial Power SaveFull Power Save Logged Data Array Identification Alarm ProcessingReal Time Clock & Calendar SecurityRemoving/Replacing the Electronic Assembly iRIS InstallationOpening / Closing the Housing iRIS 320 / iRIS Removing / fitting the SIM card GSM models onlyInternal Battery iRIS 320 / iRIS 320V only I/O ConnectorAnalog Inputs Internal / External 12V Battery SupplyExternal Charger Power Supply Digital Input Circuit Digital InputsDigital Output 1 Circuit Digital OutputsMounting iRIS Antenna ConnectionMounting iRIS 320 / iRIS IRIS 320 / iRIS 320V Mounting DiagramComputer IRIS ConfigurationTerminal Connection Terminal Cfg IRIS 220 / iRIS 320, V1.19 User Guide Main Menu Level Terminal MenusSelect this option to display the Comms configuration menu Comms Cfg Level Option 9 SDI-12 Terminal iRIS 320 / iRIS 320V only Press Esc then Enter to enter an empty string GPRS/CDMA-1X Cfg LevelGprs IP Acceptance Cfg Level Phone List LevelGPRS/CDMA-1X Schedule Cfg Level Sensor Selection Level Internal Sensor Sources Log Multiplier 100 100 Sensor Cfg LevelSupplementary Logging Flag Definitions Mode Name DescriptionFlag Value Description Multiplier= Alarm Cfg Level Alarm Selection LevelOutput Cfg Level Output Selection LevelSource 0 1 2 3 4 Description Typical Scheduled Output Example Date/Time Cfg LevelMiscellaneous Menu Level Voice Menu Level Diagnostic LEDs LED IndicatorsOperation Status LEDLCD Operation LCD & Keypad iRIS 320 onlyStatus Icons Keypad ButtonsLevel Level6 Display Menu StructureLogging Control Screen Level 0, when logged Log In Screen Level 0, when not loggedPrimary LCD Display Screens System Status 1 Screen LevelSystem Status 3 Screen Level Sensor Related ScreensSystem Status 4 Screen Level Main Menu Screen LevelSensor Settings Screen 2/5 Scaling Level Sensor Settings Screen 1/5 Process LevelSensor Settings Screen 3/5 Logging Level Sensor Settings Screen 4/5 Alarm 1 LevelTotaliser Related Screens Comms Related Screens Comms Setting Screen 3/8 Socket a Level Comms Setting Screen 2/8 APN/Local IP LevelComms Setting Screen 4/8 Socket B Level Comms Setting Screen 5/8 Schedule 1 LevelComms Setting Screen 7/8- CSD Settings Level Comms Setting Screen 6/8 Schedule 2 LevelComms Setting Screen 8/8 RS232 Settings Level RS232 Port Mode Screen LevelComms Test Screen Level Comms Enable Screen LevelSMS Communication General Hints Sensor Connection Examples Connecting a Flow Meter or Rain GaugeIris I/O Connector 12V Battery Connecting a 0-5V Pressure TransducerExternal RequiredSignal 4-20mA Sensor Isolated 12V 24V DC- DC Converter Connecting a 2-Wire Loop-Powered 4-20mA SensorRequired IRIS I/O Connector External 12V Battery Optional Connecting an Up/Down Water Level InstrumentConnecting Analogue Wind Instruments Charging source Solar panel Connecting SDI-12 Instruments. iRIS 320 / iRIS 320V onlyTOP AI4 AI3 AI2 AI1 Agnd 5VOP Example a 4-20mA Water Level Sensor Analogue Input ScalingTroubleshooting User Notes Tait TM80xx Radio DB15 MiRIS 3xx / DS-4483 DB9 F Appendix a Radio Using the RS232 InterfaceIRIS 320 DB9 F DS-IRM Modem DB25 MPartition Appendix B Voice Annunciation iRISAdvantages of SDI-12 What is SDI-12?Appendix C SDI-12 iRIS 320 / 320V only Serial Data Line SDI-12 Electrical InterfaceGround Line Volt-LineDebounce Links 13.1 I/O ConnectorAppendix D Legacy PCB Rev 1.1 Details SDI-12 Interface Diagnostic LEDsInterface Wire Terminal SDI-12 Bus Function Purple Switched Output Transistor SwitchSwitch Module REDSupply VoltageChemical Composition Appendix E iRIS 320 Enclosure Material SpecApproximate Mechanical Properties IQuest Global Data Network IQuest APN