10 Appendix A – Radio Using the RS232 Interface

The iRIS may be used to communicate via external radios. For legacy radios requiring an audio interface, a FSK modem such as the DS-IRM intelligent radio modem can be used. For radios fitted with an integral modem, the iRIS connects directly to the radio’s RS232 port. The diagram below shows the typical cable required to achieve either of these two modes of operation. The actual modem/radio connections may vary depending on the type of device used.

In all cases, the DSR line from the modem or radio is used to enable the RS232 port and the RI line sets the data rate to a fixed rate (normally 1200 bps).

Tait TM80xx Radio

DB15 (M)(iRIS 3xx / DS-4483)

DB9 (F)

SCREEN

FRAME GND

AUX_RXD (IN)

3

 

WHITE

 

 

AUX_TXD (OUT)

11

 

YELLOW

 

 

0V (SIGNAL)

15

 

BLACK

 

 

GPIO4 BUSY (OUT) 10

 

BLUE

 

 

+13V8 (OUT)

8

10K

RED

 

 

 

3 TXD (OUT)

2 RXD (IN)

5 OV (SIGNAL)

8 CTS (IN)

6 DSR (IN)

GPIO6 ENABLE (IN) 9

GREEN

9 RI (IN)

FLYING LEAD TO DIG OUT

Figure 13 – Typical RS232 / Data Radio Cable

iRIS 320 DB9 (F)

TXD (OUT)

3

RXD (IN)

2

0V (SIGNAL)

5

RTS (OUT)

7

CTS (IN)

8

DSR (IN)

6

RI (IN)

9

DS-IRM Modem

DB25 (M)

 

SCREEN

1 FRAME GND

WHITE

 

 

2 TXD (IN)

 

 

YELLOW

 

3 RXD (OUT)

 

 

BLACK

 

7 OV (SIGNAL)

 

 

BLUE

 

4 RTS (IN)

 

 

GREEN

 

5 CTS (OUT)

 

 

RED

 

6 DSR (OUT)

 

 

Figure 14 – Typical RS232 / Radio Modem Cable

Image 65
Contents IRIS 220 iRIS Revision History Contents Diagnostic LEDs 13.2 13.113.3 13.4About this Manual IntroductionHardware PCB Revision SupportIntroduction General Characteristics iRISOverview IRIS 320 / iRIS Typical Applications FeaturesFeature Summary Technical Specifications iRIS Technical Specifications iRIS 320 / iRIS Terminal Configuration Key FeaturesWireless IP Connectivity GPRS/CDMA Alternative Wireless Connectivity CSD/SMSData Logging Partial Power SaveFull Power Save Logged Data Array Identification Alarm ProcessingReal Time Clock & Calendar SecurityRemoving/Replacing the Electronic Assembly iRIS InstallationOpening / Closing the Housing iRIS 320 / iRIS Removing / fitting the SIM card GSM models onlyInternal Battery iRIS 320 / iRIS 320V only I/O ConnectorAnalog Inputs Internal / External 12V Battery SupplyExternal Charger Power Supply Digital Input Circuit Digital InputsDigital Output 1 Circuit Digital OutputsMounting iRIS Antenna ConnectionMounting iRIS 320 / iRIS IRIS 320 / iRIS 320V Mounting DiagramComputer IRIS ConfigurationTerminal Connection Terminal Cfg IRIS 220 / iRIS 320, V1.19 User Guide Main Menu Level Terminal MenusSelect this option to display the Comms configuration menu Comms Cfg Level Option 9 SDI-12 Terminal iRIS 320 / iRIS 320V only Press Esc then Enter to enter an empty string GPRS/CDMA-1X Cfg LevelGprs IP Acceptance Cfg Level Phone List LevelGPRS/CDMA-1X Schedule Cfg Level Sensor Selection Level Internal Sensor Sources Log Multiplier 100 100 Sensor Cfg LevelSupplementary Logging Flag Definitions Mode Name DescriptionFlag Value Description Multiplier= Alarm Cfg Level Alarm Selection LevelOutput Cfg Level Output Selection LevelSource 0 1 2 3 4 Description Typical Scheduled Output Example Date/Time Cfg LevelMiscellaneous Menu Level Voice Menu Level Diagnostic LEDs LED IndicatorsOperation Status LEDLCD Operation LCD & Keypad iRIS 320 onlyStatus Icons Keypad ButtonsLevel Level6 Display Menu StructureLogging Control Screen Level 0, when logged Log In Screen Level 0, when not loggedPrimary LCD Display Screens System Status 1 Screen LevelSystem Status 3 Screen Level Sensor Related ScreensSystem Status 4 Screen Level Main Menu Screen LevelSensor Settings Screen 2/5 Scaling Level Sensor Settings Screen 1/5 Process LevelSensor Settings Screen 3/5 Logging Level Sensor Settings Screen 4/5 Alarm 1 LevelTotaliser Related Screens Comms Related Screens Comms Setting Screen 3/8 Socket a Level Comms Setting Screen 2/8 APN/Local IP LevelComms Setting Screen 4/8 Socket B Level Comms Setting Screen 5/8 Schedule 1 LevelComms Setting Screen 7/8- CSD Settings Level Comms Setting Screen 6/8 Schedule 2 LevelComms Setting Screen 8/8 RS232 Settings Level RS232 Port Mode Screen LevelComms Test Screen Level Comms Enable Screen LevelSMS Communication General Hints Sensor Connection Examples Connecting a Flow Meter or Rain GaugeIris I/O Connector 12V Battery Connecting a 0-5V Pressure TransducerExternal RequiredSignal 4-20mA Sensor Isolated 12V 24V DC- DC Converter Connecting a 2-Wire Loop-Powered 4-20mA SensorRequired IRIS I/O Connector External 12V Battery Optional Connecting an Up/Down Water Level InstrumentConnecting Analogue Wind Instruments Charging source Solar panel Connecting SDI-12 Instruments. iRIS 320 / iRIS 320V onlyTOP AI4 AI3 AI2 AI1 Agnd 5VOP Example a 4-20mA Water Level Sensor Analogue Input ScalingTroubleshooting User Notes Tait TM80xx Radio DB15 MiRIS 3xx / DS-4483 DB9 F Appendix a Radio Using the RS232 InterfaceIRIS 320 DB9 F DS-IRM Modem DB25 MPartition Appendix B Voice Annunciation iRISAdvantages of SDI-12 What is SDI-12?Appendix C SDI-12 iRIS 320 / 320V only Serial Data Line SDI-12 Electrical InterfaceGround Line Volt-LineDebounce Links 13.1 I/O ConnectorAppendix D Legacy PCB Rev 1.1 Details SDI-12 Interface Diagnostic LEDsInterface Wire Terminal SDI-12 Bus Function Purple Switched Output Transistor SwitchSwitch Module REDSupply VoltageChemical Composition Appendix E iRIS 320 Enclosure Material SpecApproximate Mechanical Properties IQuest Global Data Network IQuest APN