Optiquest iRIS 220, iRIS 320 manual Comms Setting Screen 2/8 APN/Local IP Level

Page 51

49 - iRIS 220 / iRIS 320, V1.19 User Guide

Comms Setting Screen 2/8 – APN/Local IP (Level 5)

The GPRS APN screen displays the name of the access point used to connect to the GPRS network. It also displays the local IP address allocated to the SIM card inserted in the unit.

NOTE: This screen does not display an APN on CDMA versions, but will still display the iRIS’s local IP address that has been allocated by the network.

GPRS/CDMA 2/8

APN/LOCAL IP iquest.co.nz 0.0.0.0

+/-

Move forwards/backwards through communication setting screens.

Alt Enter

Move up to Comms Status screen

Comms Setting Screen 3/8 - Socket A (Level 5)

This screen displays the remote IP address and port number to use for ASCII UDP communication with a terminal application.

GPRS/CDMA 3/8

SOCKET A 0.0.0.0 Port 7778

+/-

Move forwards/backwards through communication setting screens.

Alt Enter

Move up to Comms Status screen

Comms Setting Screen 4/8 - Socket B (Level 5)

This screen displays the remote IP address and port numbers to use for System DO® UDP communication with a base station. E.g. HydroTel™ 2000

GPRS/CDMA 4/8

SOCKET B 0.0.0.0 Port 7779

+/-

Move forwards/backwards through communication setting screens.

Alt Enter

Move up to Comms Status screen

Comms Setting Screen 5/8 - Schedule 1 (Level 5)

This screen displays the time range during which the unit is allowed to make a connection to the GPRS/CDMA-1X network. Refer to the Comms Schedule (section 4.3.3) for details on these settings affect the communication availability.

GPRS/CDMA 5/8

SCHEDULE

Start 0030

End 2359

+/-

Move forwards/backwards through communication setting screens.

Alt Enter

Move up to Comms Status screen

Image 51
Contents IRIS 220 iRIS Revision History Contents Diagnostic LEDs 13.4 13.113.2 13.3Support IntroductionAbout this Manual Hardware PCB RevisionGeneral Characteristics iRIS OverviewIntroduction IRIS 320 / iRIS Features Feature SummaryTypical Applications Technical Specifications iRIS Technical Specifications iRIS 320 / iRIS Alternative Wireless Connectivity CSD/SMS Key FeaturesTerminal Configuration Wireless IP Connectivity GPRS/CDMAPartial Power Save Full Power SaveData Logging Security Alarm ProcessingLogged Data Array Identification Real Time Clock & CalendarRemoving / fitting the SIM card GSM models only InstallationRemoving/Replacing the Electronic Assembly iRIS Opening / Closing the Housing iRIS 320 / iRISInternal Battery iRIS 320 / iRIS 320V only I/O ConnectorInternal / External 12V Battery Supply External Charger Power SupplyAnalog Inputs Digital Input Circuit Digital InputsDigital Output 1 Circuit Digital OutputsMounting iRIS Antenna ConnectionMounting iRIS 320 / iRIS IRIS 320 / iRIS 320V Mounting DiagramConfiguration Terminal ConnectionComputer IRIS Terminal Cfg IRIS 220 / iRIS 320, V1.19 User Guide Main Menu Level Terminal MenusSelect this option to display the Comms configuration menu Comms Cfg Level Option 9 SDI-12 Terminal iRIS 320 / iRIS 320V only Press Esc then Enter to enter an empty string GPRS/CDMA-1X Cfg LevelGprs IP Acceptance Cfg Level Phone List LevelGPRS/CDMA-1X Schedule Cfg Level Sensor Selection Level Internal Sensor Sources Log Multiplier 100 100 Sensor Cfg LevelMode Name Description Flag Value DescriptionSupplementary Logging Flag Definitions Multiplier= Alarm Cfg Level Alarm Selection LevelOutput Cfg Level Output Selection LevelSource 0 1 2 3 4 Description Typical Scheduled Output Example Date/Time Cfg LevelMiscellaneous Menu Level Voice Menu Level Status LED LED IndicatorsDiagnostic LEDs OperationKeypad Buttons LCD & Keypad iRIS 320 onlyLCD Operation Status IconsLevel Level6 Display Menu StructureSystem Status 1 Screen Level Log In Screen Level 0, when not loggedLogging Control Screen Level 0, when logged Primary LCD Display ScreensMain Menu Screen Level Sensor Related ScreensSystem Status 3 Screen Level System Status 4 Screen LevelSensor Settings Screen 4/5 Alarm 1 Level Sensor Settings Screen 1/5 Process LevelSensor Settings Screen 2/5 Scaling Level Sensor Settings Screen 3/5 Logging LevelTotaliser Related Screens Comms Related Screens Comms Setting Screen 5/8 Schedule 1 Level Comms Setting Screen 2/8 APN/Local IP LevelComms Setting Screen 3/8 Socket a Level Comms Setting Screen 4/8 Socket B LevelRS232 Port Mode Screen Level Comms Setting Screen 6/8 Schedule 2 LevelComms Setting Screen 7/8- CSD Settings Level Comms Setting Screen 8/8 RS232 Settings LevelComms Enable Screen Level SMS CommunicationComms Test Screen Level General Hints Connecting a Flow Meter or Rain Gauge Iris I/O ConnectorSensor Connection Examples Required Connecting a 0-5V Pressure Transducer12V Battery ExternalConnecting a 2-Wire Loop-Powered 4-20mA Sensor Required IRIS I/O ConnectorSignal 4-20mA Sensor Isolated 12V 24V DC- DC Converter External 12V Battery Optional Connecting an Up/Down Water Level InstrumentConnecting Analogue Wind Instruments Charging source Solar panel Connecting SDI-12 Instruments. iRIS 320 / iRIS 320V onlyTOP AI4 AI3 AI2 AI1 Agnd 5VOP Example a 4-20mA Water Level Sensor Analogue Input ScalingTroubleshooting User Notes DS-IRM Modem DB25 M Appendix a Radio Using the RS232 InterfaceTait TM80xx Radio DB15 MiRIS 3xx / DS-4483 DB9 F IRIS 320 DB9 FPartition Appendix B Voice Annunciation iRISWhat is SDI-12? Appendix C SDI-12 iRIS 320 / 320V onlyAdvantages of SDI-12 Volt-Line SDI-12 Electrical InterfaceSerial Data Line Ground Line13.1 I/O Connector Appendix D Legacy PCB Rev 1.1 DetailsDebounce Links Diagnostic LEDs Interface Wire Terminal SDI-12 Bus FunctionSDI-12 Interface REDSupply Voltage Transistor SwitchPurple Switched Output Switch ModuleAppendix E iRIS 320 Enclosure Material Spec Approximate Mechanical PropertiesChemical Composition IQuest Global Data Network IQuest APN