1 Introduction

1.1 About this Manual

This manual is intended as a detailed guide for iRIS 200 / iRIS 320 installation, configuration and operation. For a brief operational overview, see the separate iRIS 220 Installation Guide or iRIS 320 Installation Guide.

This manual is also available online in Adobe Acrobat® pdf format for registered users atwww.iquest.co.nz

NOTE: The term “iRIS” is used throughout this manual equally applicable to either the iRIS 220 or the iRIS 320. one of the models, the full model reference will be used.

in all inst ances where the reference is When a particular section applies to only

NOTE: The term “GPRS/CDMA-1X” is used throughout this manual to refer to the wireless modem connectivity. However, the terminal menus or LCD screens on the iRIS itself will display the correct designation for the particular model e.g. “GPRS” or CDMA-1X”.

1.2 Hardware (PCB) Revision

As from firmware version 2.19 / software version 1.19, this manual has been completely updated to refer to the new version PCB (V1.2). This hardware revision has the following changes over its predecessor:

Two additional analogue inputs added.

Dedicated 5V reference output for energising potentiometer type sensors.

Digital Output 1 changed to a switched 12V output instead of open-drain pull-down. An external transistor switch is not required for powering sensors.

SDI-12 interface has been upgraded to full compliance with the SDI-12 electrical standard and to free up the digital I/O that were required for the SDI-12 function on the older hardware.

Legacy I/O and SDI-12 details referring to the older PCB revision can be found in Appendix D – Legacy PCB (Rev 1.1) Details.

1.3 Support

Technical support for the iRIS 220 and iRIS 320 is available by contacting:

iQuest (NZ) Ltd

P.O Box 15169

Hamilton

NEW ZEALAND

Tel:

+64 7 857-0810

Fax:

+64 7 857-0811

Email:

support@iquest.co.nz

For latest information and software updates, visit the iQuest (NZ) Ltd web site at www.iquest.co.nz

4

iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857-0810 Fax: +64 7 857-0811 Email: iquest@iquest.co.nz

Image 6
Contents IRIS 220 iRIS Revision History Contents Diagnostic LEDs 13.3 13.113.2 13.4Hardware PCB Revision IntroductionAbout this Manual SupportGeneral Characteristics iRIS OverviewIntroduction IRIS 320 / iRIS Features Feature SummaryTypical Applications Technical Specifications iRIS Technical Specifications iRIS 320 / iRIS Wireless IP Connectivity GPRS/CDMA Key FeaturesTerminal Configuration Alternative Wireless Connectivity CSD/SMSPartial Power Save Full Power SaveData Logging Real Time Clock & Calendar Alarm ProcessingLogged Data Array Identification SecurityOpening / Closing the Housing iRIS 320 / iRIS InstallationRemoving/Replacing the Electronic Assembly iRIS Removing / fitting the SIM card GSM models onlyI/O Connector Internal Battery iRIS 320 / iRIS 320V onlyInternal / External 12V Battery Supply External Charger Power SupplyAnalog Inputs Digital Inputs Digital Input CircuitDigital Outputs Digital Output 1 CircuitAntenna Connection Mounting iRISIRIS 320 / iRIS 320V Mounting Diagram Mounting iRIS 320 / iRISConfiguration Terminal ConnectionComputer IRIS Terminal Cfg IRIS 220 / iRIS 320, V1.19 User Guide Terminal Menus Main Menu LevelSelect this option to display the Comms configuration menu Comms Cfg Level Option 9 SDI-12 Terminal iRIS 320 / iRIS 320V only GPRS/CDMA-1X Cfg Level Press Esc then Enter to enter an empty stringGprs Phone List Level IP Acceptance Cfg LevelGPRS/CDMA-1X Schedule Cfg Level Sensor Selection Level Sensor Cfg Level Internal Sensor Sources Log Multiplier 100 100Mode Name Description Flag Value DescriptionSupplementary Logging Flag Definitions Multiplier= Alarm Selection Level Alarm Cfg LevelOutput Selection Level Output Cfg LevelSource 0 1 2 3 4 Description Date/Time Cfg Level Typical Scheduled Output ExampleMiscellaneous Menu Level Voice Menu Level Operation LED IndicatorsDiagnostic LEDs Status LEDStatus Icons LCD & Keypad iRIS 320 onlyLCD Operation Keypad ButtonsDisplay Menu Structure Level Level6Primary LCD Display Screens Log In Screen Level 0, when not loggedLogging Control Screen Level 0, when logged System Status 1 Screen LevelSystem Status 4 Screen Level Sensor Related ScreensSystem Status 3 Screen Level Main Menu Screen LevelSensor Settings Screen 3/5 Logging Level Sensor Settings Screen 1/5 Process LevelSensor Settings Screen 2/5 Scaling Level Sensor Settings Screen 4/5 Alarm 1 LevelTotaliser Related Screens Comms Related Screens Comms Setting Screen 4/8 Socket B Level Comms Setting Screen 2/8 APN/Local IP LevelComms Setting Screen 3/8 Socket a Level Comms Setting Screen 5/8 Schedule 1 LevelComms Setting Screen 8/8 RS232 Settings Level Comms Setting Screen 6/8 Schedule 2 LevelComms Setting Screen 7/8- CSD Settings Level RS232 Port Mode Screen LevelComms Enable Screen Level SMS CommunicationComms Test Screen Level General Hints Connecting a Flow Meter or Rain Gauge Iris I/O ConnectorSensor Connection Examples External Connecting a 0-5V Pressure Transducer12V Battery RequiredConnecting a 2-Wire Loop-Powered 4-20mA Sensor Required IRIS I/O ConnectorSignal 4-20mA Sensor Isolated 12V 24V DC- DC Converter Connecting an Up/Down Water Level Instrument External 12V Battery OptionalConnecting Analogue Wind Instruments Connecting SDI-12 Instruments. iRIS 320 / iRIS 320V only Charging source Solar panelTOP AI4 AI3 AI2 AI1 Agnd 5VOP Analogue Input Scaling Example a 4-20mA Water Level SensorTroubleshooting User Notes IRIS 320 DB9 F Appendix a Radio Using the RS232 InterfaceTait TM80xx Radio DB15 MiRIS 3xx / DS-4483 DB9 F DS-IRM Modem DB25 MAppendix B Voice Annunciation iRIS PartitionWhat is SDI-12? Appendix C SDI-12 iRIS 320 / 320V onlyAdvantages of SDI-12 Ground Line SDI-12 Electrical InterfaceSerial Data Line Volt-Line13.1 I/O Connector Appendix D Legacy PCB Rev 1.1 DetailsDebounce Links Diagnostic LEDs Interface Wire Terminal SDI-12 Bus FunctionSDI-12 Interface Switch Module Transistor SwitchPurple Switched Output REDSupply VoltageAppendix E iRIS 320 Enclosure Material Spec Approximate Mechanical PropertiesChemical Composition IQuest APN IQuest Global Data Network