12 Appendix C – SDI-12 (iRIS 320 / 320V only)

What is SDI-12?

SDI-12 stands for Serial Digital Interface at 1200 bps. It is a standard to interface battery powered data recorders with microprocessor-based sensors designed for environmental data acquisition (EDA).

EDA is accomplished by means of a sensor, or sensors, and a data recorder, which collects and saves the data. SDI-12 is a standard communications protocol, which provides a means to transfer measurements taken by an intelligent sensor to a data recorder. An intelligent sensor typically takes a measurement, makes computations based on the raw sensor reading, and outputs the measured data in engineering units. For example, an SDI-12 pressure sensor may take a series of pressure measurements, average them, and then output pressure in psi, inches of mercury, bars, millibars, or torrs. The sensor's microprocessor makes the computations, converts sensor readings into the appropriate units, and uses the SDI-12 protocol to transfer data to the recorder.

SDI-12 is a multi-drop interface that can communicate with multi-parameter sensors. Multi-drop means that more than one SDI-12 sensor can be connected to a data recorder. The SDI-12 bus is capable of having ten sensors connected to it. Having more than ten sensors, however, is possible. Some SDI-12 users connect more than ten sensors to a single data recorder.

Multi-parameter means that a single sensor may return more than one measurement. For example, some water quality sensors return temperature, conductivity, dissolved oxygen, pH, turbidity, and depth.

Advantages of SDI-12

A serial-digital interface is a logical choice for interfacing microprocessor-based sensors with a data recorder. This has advantages for sensors and data recorders.

Unique and complex self-calibration algorithms can be done in microprocessor-based sensors.

Sensors can be interchanged without reprogramming the data recorder with calibration or other information.

Power is supplied to sensors through the interface.

Hybrid circuit and surface mount technologies make it practical to include the power supply regulator, a microprocessor, and other needed circuitry in small sensor packages.

Sensors can use low cost EEPROMs (electrically erasable programmable read only memory) for calibration coefficients and other information instead of internal trimming operations.

The use of a standard serial interface eliminates significant complexity in the design of data recorders.

Data recorders can be designed and produced independently of future sensor development.

SDI-12 data recorders interface with a variety of sensors.

SDI-12 sensors interface with a variety of data recorders.

Personnel trained in SDI-12 will have skills to work with a variety of SDI-12 data recorders and SDI- 12 sensors.

Image 67
Contents IRIS 220 iRIS Revision History Contents Diagnostic LEDs 13.4 13.113.2 13.3Support IntroductionAbout this Manual Hardware PCB RevisionOverview General Characteristics iRISIntroduction IRIS 320 / iRIS Feature Summary FeaturesTypical Applications Technical Specifications iRIS Technical Specifications iRIS 320 / iRIS Alternative Wireless Connectivity CSD/SMS Key FeaturesTerminal Configuration Wireless IP Connectivity GPRS/CDMAFull Power Save Partial Power SaveData Logging Security Alarm ProcessingLogged Data Array Identification Real Time Clock & CalendarRemoving / fitting the SIM card GSM models only InstallationRemoving/Replacing the Electronic Assembly iRIS Opening / Closing the Housing iRIS 320 / iRISInternal Battery iRIS 320 / iRIS 320V only I/O ConnectorExternal Charger Power Supply Internal / External 12V Battery SupplyAnalog Inputs Digital Input Circuit Digital InputsDigital Output 1 Circuit Digital OutputsMounting iRIS Antenna ConnectionMounting iRIS 320 / iRIS IRIS 320 / iRIS 320V Mounting DiagramTerminal Connection ConfigurationComputer IRIS Terminal Cfg IRIS 220 / iRIS 320, V1.19 User Guide Main Menu Level Terminal MenusSelect this option to display the Comms configuration menu Comms Cfg Level Option 9 SDI-12 Terminal iRIS 320 / iRIS 320V only Press Esc then Enter to enter an empty string GPRS/CDMA-1X Cfg LevelGprs IP Acceptance Cfg Level Phone List LevelGPRS/CDMA-1X Schedule Cfg Level Sensor Selection Level Internal Sensor Sources Log Multiplier 100 100 Sensor Cfg LevelFlag Value Description Mode Name DescriptionSupplementary Logging Flag Definitions Multiplier= Alarm Cfg Level Alarm Selection LevelOutput Cfg Level Output Selection LevelSource 0 1 2 3 4 Description Typical Scheduled Output Example Date/Time Cfg LevelMiscellaneous Menu Level Voice Menu Level Status LED LED IndicatorsDiagnostic LEDs OperationKeypad Buttons LCD & Keypad iRIS 320 onlyLCD Operation Status IconsLevel Level6 Display Menu StructureSystem Status 1 Screen Level Log In Screen Level 0, when not loggedLogging Control Screen Level 0, when logged Primary LCD Display ScreensMain Menu Screen Level Sensor Related ScreensSystem Status 3 Screen Level System Status 4 Screen LevelSensor Settings Screen 4/5 Alarm 1 Level Sensor Settings Screen 1/5 Process LevelSensor Settings Screen 2/5 Scaling Level Sensor Settings Screen 3/5 Logging LevelTotaliser Related Screens Comms Related Screens Comms Setting Screen 5/8 Schedule 1 Level Comms Setting Screen 2/8 APN/Local IP LevelComms Setting Screen 3/8 Socket a Level Comms Setting Screen 4/8 Socket B LevelRS232 Port Mode Screen Level Comms Setting Screen 6/8 Schedule 2 LevelComms Setting Screen 7/8- CSD Settings Level Comms Setting Screen 8/8 RS232 Settings LevelSMS Communication Comms Enable Screen LevelComms Test Screen Level General Hints Iris I/O Connector Connecting a Flow Meter or Rain GaugeSensor Connection Examples Required Connecting a 0-5V Pressure Transducer12V Battery ExternalRequired IRIS I/O Connector Connecting a 2-Wire Loop-Powered 4-20mA SensorSignal 4-20mA Sensor Isolated 12V 24V DC- DC Converter External 12V Battery Optional Connecting an Up/Down Water Level InstrumentConnecting Analogue Wind Instruments Charging source Solar panel Connecting SDI-12 Instruments. iRIS 320 / iRIS 320V onlyTOP AI4 AI3 AI2 AI1 Agnd 5VOP Example a 4-20mA Water Level Sensor Analogue Input ScalingTroubleshooting User Notes DS-IRM Modem DB25 M Appendix a Radio Using the RS232 InterfaceTait TM80xx Radio DB15 MiRIS 3xx / DS-4483 DB9 F IRIS 320 DB9 FPartition Appendix B Voice Annunciation iRISAppendix C SDI-12 iRIS 320 / 320V only What is SDI-12?Advantages of SDI-12 Volt-Line SDI-12 Electrical InterfaceSerial Data Line Ground LineAppendix D Legacy PCB Rev 1.1 Details 13.1 I/O ConnectorDebounce Links Interface Wire Terminal SDI-12 Bus Function Diagnostic LEDsSDI-12 Interface REDSupply Voltage Transistor SwitchPurple Switched Output Switch ModuleApproximate Mechanical Properties Appendix E iRIS 320 Enclosure Material SpecChemical Composition IQuest Global Data Network IQuest APN