6.5 Connecting Analogue Wind Instruments

A relatively common type of digital water level instrument is one that provides two pulse outputs. One output generates a pulse for each increment and the other for each decrement in level. The iRIS maintains a record of these steps and therefore the relative level.

These instruments normally require a 12V supply and this is readily obtained from the iRIS. A supplementary 12V battery can be connected if desired. Typically, this type of instrument requires very little current, so the internal iRIS 320 battery will normally suffice.

The diagram below shows the required connects for such an installation. The incrementing output must be connected to DI1 and the decrementing output to DI2.

TOP

AI4

SUPPLY

Wind Direction

AI3

AI2

AI1

AGND 5VOP DI2 DI1 DO2

DO1

 

SDI-12

 

DGND

 

12V+

 

GND (-)

 

VIN+

Charging source

GND (-)

e.g solar panel

 

BOTTOM

iRIS I/O Connector

SIGNAL Sensor

GND

Wind

PULSE Speed

+12V Sensor

0V

-+

External

12V Battery

(Optional)

Image 59
Contents IRIS 220 iRIS Revision History Contents Diagnostic LEDs 13.4 13.113.2 13.3Support IntroductionAbout this Manual Hardware PCB RevisionIntroduction General Characteristics iRISOverview IRIS 320 / iRIS Typical Applications FeaturesFeature Summary Technical Specifications iRIS Technical Specifications iRIS 320 / iRIS Alternative Wireless Connectivity CSD/SMS Key FeaturesTerminal Configuration Wireless IP Connectivity GPRS/CDMAData Logging Partial Power SaveFull Power Save Security Alarm ProcessingLogged Data Array Identification Real Time Clock & CalendarRemoving / fitting the SIM card GSM models only InstallationRemoving/Replacing the Electronic Assembly iRIS Opening / Closing the Housing iRIS 320 / iRISInternal Battery iRIS 320 / iRIS 320V only I/O ConnectorAnalog Inputs Internal / External 12V Battery SupplyExternal Charger Power Supply Digital Input Circuit Digital InputsDigital Output 1 Circuit Digital OutputsMounting iRIS Antenna ConnectionMounting iRIS 320 / iRIS IRIS 320 / iRIS 320V Mounting DiagramComputer IRIS ConfigurationTerminal Connection Terminal Cfg IRIS 220 / iRIS 320, V1.19 User Guide Main Menu Level Terminal MenusSelect this option to display the Comms configuration menu Comms Cfg Level Option 9 SDI-12 Terminal iRIS 320 / iRIS 320V only Press Esc then Enter to enter an empty string GPRS/CDMA-1X Cfg LevelGprs IP Acceptance Cfg Level Phone List LevelGPRS/CDMA-1X Schedule Cfg Level Sensor Selection Level Internal Sensor Sources Log Multiplier 100 100 Sensor Cfg LevelSupplementary Logging Flag Definitions Mode Name DescriptionFlag Value Description Multiplier= Alarm Cfg Level Alarm Selection LevelOutput Cfg Level Output Selection LevelSource 0 1 2 3 4 Description Typical Scheduled Output Example Date/Time Cfg LevelMiscellaneous Menu Level Voice Menu Level Status LED LED IndicatorsDiagnostic LEDs OperationKeypad Buttons LCD & Keypad iRIS 320 onlyLCD Operation Status IconsLevel Level6 Display Menu StructureSystem Status 1 Screen Level Log In Screen Level 0, when not loggedLogging Control Screen Level 0, when logged Primary LCD Display ScreensMain Menu Screen Level Sensor Related ScreensSystem Status 3 Screen Level System Status 4 Screen LevelSensor Settings Screen 4/5 Alarm 1 Level Sensor Settings Screen 1/5 Process LevelSensor Settings Screen 2/5 Scaling Level Sensor Settings Screen 3/5 Logging LevelTotaliser Related Screens Comms Related Screens Comms Setting Screen 5/8 Schedule 1 Level Comms Setting Screen 2/8 APN/Local IP LevelComms Setting Screen 3/8 Socket a Level Comms Setting Screen 4/8 Socket B LevelRS232 Port Mode Screen Level Comms Setting Screen 6/8 Schedule 2 LevelComms Setting Screen 7/8- CSD Settings Level Comms Setting Screen 8/8 RS232 Settings LevelComms Test Screen Level Comms Enable Screen LevelSMS Communication General Hints Sensor Connection Examples Connecting a Flow Meter or Rain GaugeIris I/O Connector Required Connecting a 0-5V Pressure Transducer12V Battery ExternalSignal 4-20mA Sensor Isolated 12V 24V DC- DC Converter Connecting a 2-Wire Loop-Powered 4-20mA SensorRequired IRIS I/O Connector External 12V Battery Optional Connecting an Up/Down Water Level InstrumentConnecting Analogue Wind Instruments Charging source Solar panel Connecting SDI-12 Instruments. iRIS 320 / iRIS 320V onlyTOP AI4 AI3 AI2 AI1 Agnd 5VOP Example a 4-20mA Water Level Sensor Analogue Input ScalingTroubleshooting User Notes DS-IRM Modem DB25 M Appendix a Radio Using the RS232 InterfaceTait TM80xx Radio DB15 MiRIS 3xx / DS-4483 DB9 F IRIS 320 DB9 FPartition Appendix B Voice Annunciation iRISAdvantages of SDI-12 What is SDI-12?Appendix C SDI-12 iRIS 320 / 320V only Volt-Line SDI-12 Electrical InterfaceSerial Data Line Ground LineDebounce Links 13.1 I/O ConnectorAppendix D Legacy PCB Rev 1.1 Details SDI-12 Interface Diagnostic LEDsInterface Wire Terminal SDI-12 Bus Function REDSupply Voltage Transistor SwitchPurple Switched Output Switch ModuleChemical Composition Appendix E iRIS 320 Enclosure Material SpecApproximate Mechanical Properties IQuest Global Data Network IQuest APN