SMC Networks EX500 manual SMC Corporation

Page 1

NO. EX## - OME0008

TECHNICAL INSTRUCTION MANUAL

For EX500 SERIAL SYSTEM

Gateway ( GW ) Unit

Rockwell Automation Remote I/O ( RIO )

: EX500 - GAB1 - X1

DeviceNet

: EX500 - GDN1

PROFIBUS-DP

: EX500 - GPR1

Input Unit Manifold

Input Manifold

: EEX500 - IB1 - □□ ( -X1 )

Input Unit

: EX500 - IB1 ( -X1 )

M8 Input Block ( PNP )

: EX500 - IE1 ( -X1 )

M8 Input Block ( NPN )

: EX500 - IE2 ( -X1 )

M12 Input Block ( PNP )

: EX500 - IE3 ( -X1 )

M12 Input Block ( NPN )

: EX500 - IE4 ( -X1 )

8 point unit Input Block ( PNP, M8 )

: EX500 - IE5 ( -X1 )

8 point unit Input Block ( NPN, M8 )

: EX500 - IE6 ( -X1 )

SI Unit

SV series

: EX500 - S001 ( -X1 )

VQC series ( NPN output ( + COM. ))

: EX500 - Q001 ( -X1 )

VQC series ( PNP output ( - COM. ))

: EX500 - Q101 ( -X1 )

 

 

SMC CORPORATION

Image 1
Contents SMC Corporation ・Safety instructions for electric equipment ・Safety instructions for pneumatic equipment・Level of potential hazard ! Caution ・Safety instructions for cables・Safety instructions for power supply Index EX500 Serial System Input / Output Unit Outline Gateway GW UnitSystem Structure Test Procedure Specification Criterion Specification・EMC Directive 89 / 336 / EEC Electromagnetic EmissionHow to Order 5 0 0 G D N Gateway GW Unit specificationDeviceNet communication specification EX500 GDN1 PROFIBUS-DP EN50170 PROFIBUS-DP communication specification EX500 GPR1Input Unit Manifold Input Unit specification1. Input Manifold 2. Input UnitHow to Order 5 0 0 I E Input Block specification3. Input Block SI Unit SI Unit specificationApplicable Manifold Valve series SI Unit for SV series Manifold ValveCommunication Connector Cable for DeviceNet EX500 GDN1 Electric specificationCable specification OptionHow to Order 5 0 0 a C 0 3 0 S S P S 2. Branch Cable with M12 Connector4. Terminal Plug 3. Power Supply Connector Cable5. Water Proof Cap ・Representative PLC Parts descriptionDisplay Content Operation settingLED display 2. Operation setting switch SW2 1. Operation setting switch SW1Setting Operation Layout of scanner I/O 3. Terminating resistance setting switch SW3Data Rate State of SW3・Wiring length How to operate EX500 GDN1 DeviceNet Connection style・Cable specification EDO Figure of setting switch 2. Data rate setting switch SW3 1. Address setting switch SW1I/O memory map ・Communication speed and Longest wiring length How to operate EX500 GPR1 PROFIBUS-DP Communication wiring・Terminating resistance DIA 2. Terminating resistance setting switch SW4 1. Address setting switch SW1, 2・In case of corresponding with Word State of SW4・In case of corresponding with Double Word Input Unit Manifold Parts description Power supply must be reset after fixing the short circuitCorrespondence of input number and Input Block Input UnitExploded view / Input Unit Manifold ・Parts list Parts name Parts number・Addition of the Input Block SV series Manifold Valve Parts descriptionVQC series SI Unit for SV series ManifoldCorrespondence of output number and Manifold Valve SI Unit for SV series Manifold How to install the SI UnitSI Unit for VQC series Manifold Source wiring WiringIndividual power supply Single power supply2. Communication wiring to the SI Unit and the Input Unit Communication wiring 1. Communication wiring to PLCRemote I/O EX500 GAB1 -X1 communication wiring DeviceNet EX500 GDN1 communication wiring・In case of M8 Input Block Dimension 10 -1. Gateway GW Unit 10 -2. Input Unit ManifoldStations ・In case of M12 Input Block 10 -3. Manifold Valve・Whole system Remedies Trouble shooting・Remote I/O communication Remedies ・PROFIBUS-DP communication Remedies ・DeviceNet communication RemediesStatus of MS LED Status of NS LED