SMC Networks EX500 manual Correspondence of output number and Manifold Valve

Page 33

EX500 Serial System

EX## - OME0008

8 -2.Correspondence of output number and Manifold Valve

The output number to the Manifold Valve of the SI Unit is shown in the following figure. The SI Unit has output of 16 points.

In case of the Relay Output Module ( 1 output ), it becomes like the Single solenoid valve. In case of the Relay Output Module ( 2 output ), it becomes like the Double solenoid valve.

B

A

 

 

 

15

14

Double

 

13

12

Double

 

11

10

Double

 

9

8

Double

 

7

6

Double

 

5

4

Double

 

3

2

Double

 

1

0

Double

 

 

B

A

 

 

 

 

 

15

14

Double

 

 

U

 

13

Single

 

 

 

side

 

12

Single

 

11

10

Double

 

 

 

9

8

Double

 

 

 

 

7

Single

 

 

6

Single

 

 

5

Single

 

4

3

Double

 

 

 

 

2

Single

 

1

0

Double

 

 

D

 

 

 

side

 

 

 

B

A

 

 

 

U

 

 

side

 

 

 

15

Single

 

14

Single

 

13

Single

 

12

Single

 

11

Single

 

10

Single

 

8

Single

 

6

Single

5

4

Double

 

3

2

Double

 

1

0

Double

 

D

 

 

side

 

 

U

side

Wired for single solenoid

Wired for double solenoid

D

side

SI Unit

SI Unit

SI Unit

Example 1 : 8 stations double

Example 2 : Single and double solenoid

solenoid valve

 

valves are mixed

CAUTION

The Manifold Valve combination of Example “ 2 “shows the single solenoid valve using the Manifold Block Ass'y wired for single solenoid and the double solenoid valve using Manifold Block Ass'y wired for double wiring.

Confirm the Manifold Block assembly configuration i.e. wired for single solenoid or wired for double solenoid before making a control program and so on.

- 32 -

Image 33
Contents SMC Corporation ・Safety instructions for pneumatic equipment ・Safety instructions for electric equipment・Level of potential hazard ! Caution ・Safety instructions for cables・Safety instructions for power supply Index EX500 Serial System Outline Gateway GW Unit Input / Output UnitSystem Structure Test Procedure Specification Criterion Specification・EMC Directive 89 / 336 / EEC Electromagnetic EmissionHow to Order 5 0 0 G D N Gateway GW Unit specificationDeviceNet communication specification EX500 GDN1 PROFIBUS-DP EN50170 PROFIBUS-DP communication specification EX500 GPR1Input Unit Manifold Input Unit specification1. Input Manifold 2. Input UnitInput Block specification How to Order 5 0 0 I E3. Input Block SI Unit SI Unit specificationApplicable Manifold Valve series SI Unit for SV series Manifold ValveCommunication Connector Cable for DeviceNet EX500 GDN1 Electric specificationCable specification OptionHow to Order 5 0 0 a C 0 3 0 S S P S 2. Branch Cable with M12 Connector3. Power Supply Connector Cable 4. Terminal Plug5. Water Proof Cap ・Representative PLC Parts descriptionOperation setting Display ContentLED display 1. Operation setting switch SW1 2. Operation setting switch SW2Setting Operation Layout of scanner I/O 3. Terminating resistance setting switch SW3Data Rate State of SW3How to operate EX500 GDN1 DeviceNet Connection style ・Wiring length・Cable specification EDO Figure of setting switch 1. Address setting switch SW1 2. Data rate setting switch SW3I/O memory map How to operate EX500 GPR1 PROFIBUS-DP Communication wiring ・Communication speed and Longest wiring length・Terminating resistance DIA 2. Terminating resistance setting switch SW4 1. Address setting switch SW1, 2・In case of corresponding with Word State of SW4・In case of corresponding with Double Word Input Unit Manifold Parts description Power supply must be reset after fixing the short circuit Correspondence of input number and Input Block Input Unit・Parts list Parts name Parts number Exploded view / Input Unit Manifold・Addition of the Input Block SV series Manifold Valve Parts descriptionVQC series SI Unit for SV series ManifoldCorrespondence of output number and Manifold Valve How to install the SI Unit SI Unit for SV series ManifoldSI Unit for VQC series Manifold Source wiring WiringIndividual power supply Single power supply2. Communication wiring to the SI Unit and the Input Unit Communication wiring 1. Communication wiring to PLCRemote I/O EX500 GAB1 -X1 communication wiring DeviceNet EX500 GDN1 communication wiringDimension 10 -1. Gateway GW Unit 10 -2. Input Unit Manifold ・In case of M8 Input BlockStations ・In case of M12 Input Block 10 -3. Manifold ValveTrouble shooting ・Whole system Remedies・Remote I/O communication Remedies ・PROFIBUS-DP communication Remedies ・DeviceNet communication RemediesStatus of MS LED Status of NS LED