9. Wiring

CAUTION

Wire each cables after turning the power supply OFF.

9 -1. Source wiring

Wiring from power supply to GW’s power supply connector is called Source wiring. ( Refer to section 4 -2, 5 -2, 6 -2 )

For pin out of this connector refer to section 3 -2. It is not necessary to supply power to SI Unit, Valve Manifold Block and Input Unit Manifold Block individually.

Power to these units will be supplied from GW Unit’s power supply connector. Refer to “ Safety instructions for power supply ” when selecting a power supply.

It is recommended to use SMC specified cable for source wiring. ( Refer to section 3 -6 -3 )

CAUTION

As shown in the following two figures a single power supply or 2 individual power supplies can be used to supply power to SI Unit and Solenoid Valve Manifold.

A. Individual power supply

 

Brown : 0V ( for solenoid valve)

 

White : 24V DC +10% / -5% ( for solenoid valve)

 

Gray : PE

 

Blue : 0V ( for power source)

24V DC

Black : 24V DC ±10% ( for power source)

2 1

5

34

24V DC

P/N : EX500 - AP※※※ -

Power connector for GW Unit

B. Single power supply

24V DC

Brown : 0V ( for solenoid valve)

White : 24V DC +10% / -5% ( for solenoid valve)

Gray : PE

Blue : 0V ( for power source)

Black : 24V DC ±10% ( for power source)

P/N : EX500 - AP※※※ -

2 1

5

34

Power connector for GW Unit

- 34 -

Image 35
Contents SMC Corporation ・Level of potential hazard ・Safety instructions for pneumatic equipment・Safety instructions for electric equipment ! Caution ・Safety instructions for cables・Safety instructions for power supply Index EX500 Serial System System Structure Outline Gateway GW UnitInput / Output Unit Electromagnetic Emission SpecificationTest Procedure Specification Criterion ・EMC Directive 89 / 336 / EECHow to Order 5 0 0 G D N Gateway GW Unit specificationDeviceNet communication specification EX500 GDN1 PROFIBUS-DP EN50170 PROFIBUS-DP communication specification EX500 GPR12. Input Unit Input Unit specificationInput Unit Manifold 1. Input Manifold3. Input Block Input Block specificationHow to Order 5 0 0 I E SI Unit for SV series Manifold Valve SI Unit specificationSI Unit Applicable Manifold Valve seriesOption Electric specificationCommunication Connector Cable for DeviceNet EX500 GDN1 Cable specificationHow to Order 5 0 0 a C 0 3 0 S S P S 2. Branch Cable with M12 Connector5. Water Proof Cap 3. Power Supply Connector Cable4. Terminal Plug ・Representative PLC Parts descriptionLED display Operation settingDisplay Content Setting Operation 1. Operation setting switch SW12. Operation setting switch SW2 State of SW3 3. Terminating resistance setting switch SW3Layout of scanner I/O Data Rate・Cable specification How to operate EX500 GDN1 DeviceNet Connection style・Wiring length EDO Figure of setting switch I/O memory map 1. Address setting switch SW12. Data rate setting switch SW3 ・Terminating resistance How to operate EX500 GPR1 PROFIBUS-DP Communication wiring・Communication speed and Longest wiring length DIA State of SW4 1. Address setting switch SW1, 22. Terminating resistance setting switch SW4 ・In case of corresponding with Word・In case of corresponding with Double Word Input Unit Power supply must be reset after fixing the short circuitInput Unit Manifold Parts description Correspondence of input number and Input Block・Addition of the Input Block ・Parts list Parts name Parts numberExploded view / Input Unit Manifold SI Unit for SV series Manifold Manifold Valve Parts descriptionSV series VQC seriesCorrespondence of output number and Manifold Valve SI Unit for VQC series Manifold How to install the SI UnitSI Unit for SV series Manifold Single power supply WiringSource wiring Individual power supplyDeviceNet EX500 GDN1 communication wiring Communication wiring 1. Communication wiring to PLC2. Communication wiring to the SI Unit and the Input Unit Remote I/O EX500 GAB1 -X1 communication wiringStations Dimension 10 -1. Gateway GW Unit 10 -2. Input Unit Manifold・In case of M8 Input Block ・In case of M12 Input Block 10 -3. Manifold Valve・Remote I/O communication Remedies Trouble shooting・Whole system Remedies Status of NS LED ・DeviceNet communication Remedies・PROFIBUS-DP communication Remedies Status of MS LED