SMC Networks EX500 manual ・Safety instructions for cables, ! Caution

Page 3

EX500 Serial System

EX## - OME0008

CAUTION

1.Read this manual thoroughly, and operate this product within the range of the specification after observing notes strictly.

2.Do not drop nor apply force to the product.

It may damage the unit, and may cause failure or malfunction.

3.Take appropriate measures to ensure that the specified power is supplied regardless of the condition of power supply.

Use within specified voltage range. To use outside of specified voltage will cause malfunction, damage to unit, electric shock, and fire.

4.Do not touch the terminal or internal circuit board while they are energized. It may cause malfunction, damage to unit, and electric shock.

Turn the power supply OFF when increasing / decreasing the number of Input Block or the Manifold Valve, and disconnecting the power supply.

5.Use within operating ambient temperature. Do not use where temperatures can rapidly change even though it is within the specifications.

6.Foreign objects should be prevented from entering the product. Contamination by foreign objects, such as wire chips will cause fire, breakage, and malfunction.

7.Use within the operating environment of the protection structure.

IP65 is achieved by proper mounting of Input Unit / Input Block and Manifold Valve with SI Unit and

by processing properly a cable with the M12 connector which is wiring each unit, and a cable which is wiring for power supply, and a connector which is setting for communication, and by processing properly with

the water - proof cap when there is an unused port.

Take measures such as the covers to be used in the environment in which water splashes always.

8. Operate within the specified tightening torque.

It will be possible to damage the screw when the screw is tightening exceeds the range of the tightening torque.

9.Take appropriate and sufficient countermeasures when installing systems in the following locations.

Locations subject to static electricity or other forms of noise.

Locations subject to strong electromagnetic fields.

Locations subject to possible exposure to radioactivities.

Locations close to power supplies.

10.Take appropriate measures to noise such as the noise filter and so on, when installing this product in equipment.

11.This product is a component, which is installed in the final equipment and used.

Please confirm the adaptability of EMC instruction when being installed in equipment by the customer.

12.Do not detach the nameplate.

13.Carry out periodical checks to confirm correct operation.

Safety may not be maintained by unintentional malfunction or incorrect operation.

Safety instructions for cables

CAUTION

1.Pay attention to wrong wiring.

It will cause malfunction, fire and damage to the unit.

2.Do not wire the power line with the high-voltage wire to prevent the signal line from the noise serge. It will cause the malfunction.

3.Confirm the non-conductivity of wiring. It will cause the unit to be damaged by the excessive electric current flowing and voltage's being impressed, when there is an insufficient insulation resistance.

4.Do not bend cable repeatedly, or pull the cable, or put a heavy object on the cable.

- 2 -

Image 3
Contents SMC Corporation ・Safety instructions for pneumatic equipment ・Safety instructions for electric equipment・Level of potential hazard ! Caution ・Safety instructions for cables・Safety instructions for power supply Index EX500 Serial System Outline Gateway GW Unit Input / Output UnitSystem Structure Electromagnetic Emission SpecificationTest Procedure Specification Criterion ・EMC Directive 89 / 336 / EECHow to Order 5 0 0 G D N Gateway GW Unit specificationDeviceNet communication specification EX500 GDN1 PROFIBUS-DP EN50170 PROFIBUS-DP communication specification EX500 GPR12. Input Unit Input Unit specificationInput Unit Manifold 1. Input ManifoldInput Block specification How to Order 5 0 0 I E3. Input Block SI Unit for SV series Manifold Valve SI Unit specificationSI Unit Applicable Manifold Valve seriesOption Electric specificationCommunication Connector Cable for DeviceNet EX500 GDN1 Cable specificationHow to Order 5 0 0 a C 0 3 0 S S P S 2. Branch Cable with M12 Connector3. Power Supply Connector Cable 4. Terminal Plug5. Water Proof Cap ・Representative PLC Parts descriptionOperation setting Display ContentLED display 1. Operation setting switch SW1 2. Operation setting switch SW2Setting Operation State of SW3 3. Terminating resistance setting switch SW3Layout of scanner I/O Data RateHow to operate EX500 GDN1 DeviceNet Connection style ・Wiring length・Cable specification EDO Figure of setting switch 1. Address setting switch SW1 2. Data rate setting switch SW3I/O memory map How to operate EX500 GPR1 PROFIBUS-DP Communication wiring ・Communication speed and Longest wiring length・Terminating resistance DIA State of SW4 1. Address setting switch SW1, 22. Terminating resistance setting switch SW4 ・In case of corresponding with Word・In case of corresponding with Double Word Input Unit Power supply must be reset after fixing the short circuitInput Unit Manifold Parts description Correspondence of input number and Input Block・Parts list Parts name Parts number Exploded view / Input Unit Manifold・Addition of the Input Block SI Unit for SV series Manifold Manifold Valve Parts descriptionSV series VQC seriesCorrespondence of output number and Manifold Valve How to install the SI Unit SI Unit for SV series ManifoldSI Unit for VQC series Manifold Single power supply WiringSource wiring Individual power supplyDeviceNet EX500 GDN1 communication wiring Communication wiring 1. Communication wiring to PLC2. Communication wiring to the SI Unit and the Input Unit Remote I/O EX500 GAB1 -X1 communication wiringDimension 10 -1. Gateway GW Unit 10 -2. Input Unit Manifold ・In case of M8 Input BlockStations ・In case of M12 Input Block 10 -3. Manifold ValveTrouble shooting ・Whole system Remedies・Remote I/O communication Remedies Status of NS LED ・DeviceNet communication Remedies・PROFIBUS-DP communication Remedies Status of MS LED