EX500 Serial System | EX## - OME0008 |
・Communication specification for each PLC
Rockwell Automation Remote I/O communication specification ( RIO ) ( EX500 - GAB1 - X1 )
Item
Specification
Applicable PLC | Rockwell Automation Remote I/O PLC |
|
| |
Communication speed | 57.6 k bit / sec. , 115.2 k bit / sec. , 230.4 k bit / sec. |
| ||
Cable distance | 57.6 k bit / sec. : 3048 m [ 10000 feet ] ( 150Ω) |
|
| |
115.2 k bit / sec. : 1524 m [ 5000 feet ] ( 150Ω) |
|
| ||
( Terminating resistor size ) |
|
| ||
230.4 k bit / sec. : 762 m [ 2500 feet ] ( 82Ω) |
|
| ||
|
|
| ||
| M12 connector ( 4 pin, plug ) |
| 1 | |
| Pin NO. | 2 | ||
Communication connector | 1. | Line1 ( Blue ) |
|
|
2. | N. C. | 3 | 4 | |
| 3. | Line2 ( Clear ) | ||
|
|
| ||
| 4. | Shield ( Shield ) | For GW Unit | |
|
|
|
|
|
DeviceNet communication specification ( EX500 - GDN1 )
Item
Specification
Communication protocol | DeviceNet Release 2.0 |
|
| ||
Slave ( branch ) type | Group2 Only Server |
|
| ||
MAC ID setting range | 0 to 63 |
|
| ||
| Vender code : 7 ( SMC corp. ) |
|
| ||
Device information | Product type : 12 ( Communication Adapter ) |
|
| ||
| Product code : 5001 |
|
| ||
| Duplicate MAC ID Check Message |
|
| ||
Corresponding message | Group2 Only Unconnected Explicit Message |
|
| ||
Explicit Message |
|
| |||
|
|
| |||
| Poll I/O Message |
|
| ||
I/O message size | Input : 8 byte , Output : 8 byte |
|
| ||
Communication speed | 125 k bit / sec. , 250 k bit / sec. , 500 k bit / sec. |
|
| ||
Cable distance | Refer to section 5 |
|
| ||
Isolation | Photo coupler |
|
| ||
( between CAN transceiver - main circuit ) |
|
| |||
|
|
| |||
| M12 connector ( 5 pin, plug ) |
|
| ||
| Pin NO. | 2 | 1 | ||
| 1. | DRAIN |
| 5 | |
Communication connector | 2. | V+ |
|
| |
3. | V- | 3 | 4 | ||
| |||||
| 4. | CAN_H | For GW Unit | ||
| 5. | CAN_L | |||
|
|
|
|
|
- 9 -