EX500 Serial System | EX## - OME0008 |
3
How to Order
E X 5 0 0 - G D N 1
Network communication |
|
protocol | GW Unit compatible |
|
DN | DeviceNet |
| Nil | DeviceNet |
PR |
|
| ||
|
| |||
AB | Remote I/O ( RIO ) |
| Remote I/O ( RIO ) | |
|
|
|
|
|
B |
|
|
|
|
|
|
|
|
|
|
US |
|
|
|
|
|
|
|
|
|
|
RUN |
|
|
|
|
|
|
|
|
|
|
SOL |
|
|
|
|
|
|
|
|
|
|
COM |
|
|
|
|
|
|
|
|
|
|
ERR |
| EX5GATEWA |
|
|
|
|
|
|
| |
24VDC |
|
|
|
|
|
|
|
| ||
|
| 00 | Y | UNIT |
|
|
|
|
| |
|
|
| SER |
|
|
|
|
| ||
|
|
| IES |
|
|
|
|
|
| |
S |
|
|
|
|
|
|
|
|
| |
| MC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RISE |
|
|
|
|
|
| NI ED MA |
| N | LA C IP | |
|
|
|
|
|
| O. E | DO PU IN | |||
|
|
|
|
| AN AP J |
| 5 P6 ITU PT | UO | /GATTL VO | |
|
|
|
|
|
|
| 4 6 | 42 | E |
|
COM |
|
|
|
|
| 64/20/C VD | 05XE | |||
D |
|
|
|
| A m0 |
|
|
| ||
|
|
|
|
| BAG |
|
|
| ||
|
|
| SU | C |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| PE |
.
Gateway ( GW ) Unit
Gateway ( GW ) Unit specification
Item
Specification
Models |
| EX500 - GAB1 - X1 |
| EX500 - GDN1 |
| EX500 - GPR1 | ||||
Rated voltage |
|
|
|
|
| 24V DC |
|
|
| |
|
|
|
| Input and control power supply : 24V DC ±10% |
| |||||
Power supply |
|
|
| Solenoid valve power supply : 24V DC +10% / |
| |||||
|
| ( Warning of voltage drop given lower than approx. 20V ) |
| |||||||
voltage |
|
|
|
|
| Communication power |
|
|
| |
|
|
| - |
|
| supply for DeviceNet : |
|
| - | |
|
|
|
|
|
| 11V DC to 25V DC |
|
|
| |
Current |
|
|
|
|
| 200mA or less ( only GW Unit ) |
|
|
| |
|
|
|
|
| Communication power |
|
|
| ||
consumption |
|
| - |
|
| supply for DeviceNet : |
|
| - | |
|
|
|
|
|
| 50mA or less |
|
|
| |
Input / Output |
|
|
| Maximum 64 inputs / Maximum 64 outputs |
|
| ||||
points |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||
Input / Output |
|
|
| 4 branches ( one branch 16 inputs / 16 outputs ) |
| |||||
branches |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| ||
| M12 connector ( 8 pin, socket ) |
|
| |||||||
| Pin NO. |
|
|
|
|
|
|
| ||
| 1. | RD + | 2. | RD - |
|
|
| 1 | 2 | |
Branch | 3. | TD + | 4. | TD - | 7 | 8 | 3 | |||
| ||||||||||
|
|
|
|
| ||||||
connector | 5. 24V DC ( for solenoid valve) |
|
| |||||||
6. | 0V DC ( for solenoid valve) | 6 | 4 | |||||||
| ||||||||||
| 7. 24V DC ( for power source ) | 5 |
| |||||||
|
|
|
|
|
|
|
|
| ||
| 8. | 0V DC ( for power source ) | For GW Unit | |||||||
|
|
|
| |||||||
Length of branch | Less than 5m ( Less than 10m Max. Length ) |
|
| |||||||
cable |
|
|
|
|
|
|
|
|
| |
Communication | Communication protocol : SMC original protocol |
|
| |||||||
Communication speed | : 750 k bit / sec. ( DeviceNet, |
| ||||||||
form |
| |||||||||
|
|
|
| : 500 k bit / sec. ( Remote I/O (RIO)) |
|
| ||||
|
|
|
|
|
|
| ||||
| M12 connector ( 5 pin, plug ) |
|
| |||||||
| Pin NO. |
|
|
|
|
|
|
| ||
| 1. 0V ( for solenoid valve) | 2 |
| |||||||
Power | 2. | 24V DC + 10% / - 5% 3A Max. | 1 | |||||||
|
|
|
|
|
|
|
| |||
| ( for solenoid valve) | 5 |
| |||||||
Supply |
|
|
| |||||||
3. 0V ( for power source ( input and control ) ) |
|
| ||||||||
connector |
|
| ||||||||
4. 24V DC±10% 3A Max. | 3 | 4 | ||||||||
|
|
| ||||||||
|
| ( for power source ( input and control ) ) | For GW Unit | |||||||
| 5. PE ( Protective earth ) |
|
| |||||||
|
|
|
|
|
|
|
|
| ||
Weight |
|
|
|
|
| 470g |
|
|
- 8 -