SMC Networks EX500 manual Applicable Manifold Valve series, SI Unit specification

Page 14

EX500 Serial System

EX## - OME0008

3 -4. SI Unit

SI Unit for SV series Manifold Valve

How to Order

E X 5 0 0 - S 0 0 1

GW Unit compatible

SI Unit for VQC series Manifold Valve

How to Order

E X 5 0 0 - Q 1 0 1

GW Unit compatible

Nil

DeviceNet

PROFIBUS-DP

Output specification

 

 

DeviceNet

 

 

 

 

Nil

0 NPN output ( + COM. )

PROFIBUS-DP

-X1 Remote I/O ( RIO )

1 PNP output ( - COM. )

-X1 Remote I/O ( RIO )

SI Unit specification

Item

Specification

Models

 

EX500 - S001 ( -X1 )

EX500 - Q□01 ( -X1 )

Connecting

Solenoid valve ( Single , Double )

Solenoid valve ( Single , Double )

block

Relay Output Module ( 1 output , 2 output )

 

 

 

Number

Double solenoid valve ,

: 8 blocks Max.

Double solenoid valve

: 8 blocks Max.

of

Relay Output Module ( 2 output )

 

 

 

Single solenoid valve ,

: 16 blocks Max.

 

 

 

connecting block

Single solenoid valve

: 16 blocks Max.

 

Relay Output Module ( 1 output )

 

 

 

Power supply for block

 

 

 

 

 

24V

DC

 

 

Current supply for block

 

 

0.65A Max.

 

0.75A Max.

 

Current consumption

 

 

 

100mA or less ( in case of rated voltage )

 

 

Short circuit

Use current limit driver

 

 

 

 

 

Once the driver circuit is shorted, current is limited in order to de-energize the load.

 

 

protection

 

 

Once the short circuit is fixed, the unit will self recover.

 

 

 

 

 

 

 

 

C1

 

Connecting with Input Unit.

M12 connector ( 8 pin, socket )

 

 

 

Pin NO.

 

 

 

1

2

 

 

 

1.

RD +

2.

RD -

 

7

8

 

or

 

3.

N. C.

4.

N. C.

 

3

 

 

 

 

 

 

“ 0 “

 

5.

N. C.

6.

N. C.

 

6

4

 

 

7.

24V DC ( for power source )

 

5

Communication

 

 

8.

0V DC ( for power source )

For SI Unit

 

 

Connecting with GW Unit.

M12 connector ( 8 pin, plug )

 

connector

 

 

 

C2

 

Pin NO.

 

 

 

 

 

 

 

 

 

 

2

1

 

 

1.

RD +

2.

RD -

 

 

 

 

 

 

8

 

or

 

3.

TD +

4.

TD -

 

3

7

 

 

5.

24V DC ( for solenoid valve)

 

 

 

 

 

4

6

 

“ 1“

 

6.

0V DC ( for solenoid valve)

 

 

 

5

 

 

7.

24V DC ( for power source )

 

 

 

 

For SI Unit

 

 

 

8.

0V DC ( for power source )

 

 

 

 

 

Weight

 

 

 

115g

 

 

105g

 

 

3 -5. Applicable Manifold Valve series

Series

Manifold

 

Applicable cylinder size ( mm )

 

Cassette

Tie-rod

40

50

63

80

100

125

 

type

type

 

 

 

 

 

 

 

SV1000

 

 

 

 

 

 

SV2000

 

 

 

 

 

 

SV3000

-

 

 

 

 

 

 

SV4000

-

 

 

 

 

 

 

VQC1000

-

 

 

 

 

 

 

VQC2000

-

 

 

 

 

 

 

VQC4000

-

 

 

 

 

 

 

Refer to the Catalogues or Technical Instruction Manual of SV and VQC series Manifold Valve for more details.

- 13 -

Image 14
Contents SMC Corporation ・Level of potential hazard ・Safety instructions for pneumatic equipment・Safety instructions for electric equipment ・Safety instructions for cables ! Caution・Safety instructions for power supply Index EX500 Serial System System Structure Outline Gateway GW UnitInput / Output Unit ・EMC Directive 89 / 336 / EEC SpecificationTest Procedure Specification Criterion Electromagnetic EmissionGateway GW Unit specification How to Order 5 0 0 G D NDeviceNet communication specification EX500 GDN1 PROFIBUS-DP communication specification EX500 GPR1 PROFIBUS-DP EN501701. Input Manifold Input Unit specificationInput Unit Manifold 2. Input Unit3. Input Block Input Block specificationHow to Order 5 0 0 I E Applicable Manifold Valve series SI Unit specificationSI Unit SI Unit for SV series Manifold ValveCable specification Electric specificationCommunication Connector Cable for DeviceNet EX500 GDN1 Option2. Branch Cable with M12 Connector How to Order 5 0 0 a C 0 3 0 S S P S5. Water Proof Cap 3. Power Supply Connector Cable4. Terminal Plug Parts description ・Representative PLCLED display Operation settingDisplay Content Setting Operation 1. Operation setting switch SW12. Operation setting switch SW2 Data Rate 3. Terminating resistance setting switch SW3Layout of scanner I/O State of SW3・Cable specification How to operate EX500 GDN1 DeviceNet Connection style・Wiring length EDO Figure of setting switch I/O memory map 1. Address setting switch SW12. Data rate setting switch SW3 ・Terminating resistance How to operate EX500 GPR1 PROFIBUS-DP Communication wiring・Communication speed and Longest wiring length DIA ・In case of corresponding with Word 1. Address setting switch SW1, 22. Terminating resistance setting switch SW4 State of SW4・In case of corresponding with Double Word Correspondence of input number and Input Block Power supply must be reset after fixing the short circuitInput Unit Manifold Parts description Input Unit・Addition of the Input Block ・Parts list Parts name Parts numberExploded view / Input Unit Manifold VQC series Manifold Valve Parts descriptionSV series SI Unit for SV series ManifoldCorrespondence of output number and Manifold Valve SI Unit for VQC series Manifold How to install the SI UnitSI Unit for SV series Manifold Individual power supply WiringSource wiring Single power supplyRemote I/O EX500 GAB1 -X1 communication wiring Communication wiring 1. Communication wiring to PLC2. Communication wiring to the SI Unit and the Input Unit DeviceNet EX500 GDN1 communication wiringStations Dimension 10 -1. Gateway GW Unit 10 -2. Input Unit Manifold・In case of M8 Input Block 10 -3. Manifold Valve ・In case of M12 Input Block・Remote I/O communication Remedies Trouble shooting・Whole system Remedies Status of MS LED ・DeviceNet communication Remedies・PROFIBUS-DP communication Remedies Status of NS LED