SMC Networks EX500 manual ・In case of corresponding with Double Word

Page 29

EX500 Serial System

EX## - OME0008

In case of corresponding with “ Double Word “

( m,n=0 - )

Branch

connector

Data ( 4 byte )

MSB

LSB

MSB

LSB

MSB

LSB

MSB

LSB

7

0

7

0

7

0

7

0

Double Word

COM A

 

( n, n+1 )

/ COM B

 

 

 

 

Double Word

COM C

 

( n+2, n+3 )

/ COM D

 

 

 

 

:

:

 

:

:

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

Byte (m)

 

 

 

Byte (m+1)

 

 

Byte (m+2)

 

 

Byte (m+3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte (m+4)

 

 

 

 

Byte (m+5)

 

 

Byte (m+6)

 

 

Byte (m+7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

Read carefully the user manual of PLC which is used as a master.

The method of PLC setup, reading from or writing to memory differ from one PLC manufacturer to another.

- 28 -

Image 29
Contents SMC Corporation ・Level of potential hazard ・Safety instructions for pneumatic equipment・Safety instructions for electric equipment ! Caution ・Safety instructions for cables・Safety instructions for power supply Index EX500 Serial System System Structure Outline Gateway GW UnitInput / Output Unit Test Procedure Specification Criterion Specification・EMC Directive 89 / 336 / EEC Electromagnetic EmissionHow to Order 5 0 0 G D N Gateway GW Unit specificationDeviceNet communication specification EX500 GDN1 PROFIBUS-DP EN50170 PROFIBUS-DP communication specification EX500 GPR1Input Unit Manifold Input Unit specification1. Input Manifold 2. Input Unit3. Input Block Input Block specificationHow to Order 5 0 0 I E SI Unit SI Unit specificationApplicable Manifold Valve series SI Unit for SV series Manifold ValveCommunication Connector Cable for DeviceNet EX500 GDN1 Electric specificationCable specification OptionHow to Order 5 0 0 a C 0 3 0 S S P S 2. Branch Cable with M12 Connector5. Water Proof Cap 3. Power Supply Connector Cable4. Terminal Plug ・Representative PLC Parts descriptionLED display Operation settingDisplay Content Setting Operation 1. Operation setting switch SW12. Operation setting switch SW2 Layout of scanner I/O 3. Terminating resistance setting switch SW3Data Rate State of SW3・Cable specification How to operate EX500 GDN1 DeviceNet Connection style・Wiring length EDO Figure of setting switch I/O memory map 1. Address setting switch SW12. Data rate setting switch SW3 ・Terminating resistance How to operate EX500 GPR1 PROFIBUS-DP Communication wiring ・Communication speed and Longest wiring length DIA 2. Terminating resistance setting switch SW4 1. Address setting switch SW1, 2・In case of corresponding with Word State of SW4・In case of corresponding with Double Word Input Unit Manifold Parts description Power supply must be reset after fixing the short circuitCorrespondence of input number and Input Block Input Unit・Addition of the Input Block ・Parts list Parts name Parts numberExploded view / Input Unit Manifold SV series Manifold Valve Parts descriptionVQC series SI Unit for SV series ManifoldCorrespondence of output number and Manifold Valve SI Unit for VQC series Manifold How to install the SI UnitSI Unit for SV series Manifold Source wiring WiringIndividual power supply Single power supply2. Communication wiring to the SI Unit and the Input Unit Communication wiring 1. Communication wiring to PLCRemote I/O EX500 GAB1 -X1 communication wiring DeviceNet EX500 GDN1 communication wiringStations Dimension 10 -1. Gateway GW Unit 10 -2. Input Unit Manifold・In case of M8 Input Block ・In case of M12 Input Block 10 -3. Manifold Valve・Remote I/O communication Remedies Trouble shooting・Whole system Remedies ・PROFIBUS-DP communication Remedies ・DeviceNet communication RemediesStatus of MS LED Status of NS LED