SMC Networks EX500 manual LED display, Operation setting, Display Content

Page 19

EX500 Serial System

EX## - OME0008

4 -3. LED display

BUS

RUN SOL COM ERR

GATEWAY UNIT EX500 SERIES

 

COM A

COM B

COM C

COM D

 

 

 

 

 

 

 

Display

 

 

 

Content

 

 

 

 

 

 

 

 

RUN

Source ON

: Lights

 

 

 

Source OFF

: Lights off

 

 

 

 

 

SOL

Solenoid valve source voltage is normal

:Lights

Voltage lowered to 20V or less

 

:Lights off

 

 

COM

RIO communication is normal

 

: Lights

RIO communication is abnormal

 

: Lights off

 

 

ERR

RIO communication is abnormal

 

: Lights

RIO communication is normal

 

: Lights off

 

 

COM A

Communication port A is receiving data

: Lights

Communication port A has no data

 

: Lights off

 

 

COM B

Communication port B is receiving data

: Lights

Communication port B has no data

 

: Lights off

 

 

COM C

Communication port C is receiving data

: Lights

Communication port C has no data

 

: Lights off

 

 

COM D

Communication port D is receiving data

: Lights

Communication port D has no data

 

: Lights off

 

 

CAUTION

When the Input Unit Manifold is not connected, the respective COM LED of the GW Unit will not light up. To monitor the status of COM port, it is necessary to use a Terminal Plug.

The COM LED will light up when a Terminal Plug is used. ( Refer to section 3 -6 -4 )

4 -4. Operation setting

Turn the power supply OFF when setting switches.

Open the station switch protection cover and set the dip switch with a flat blade screw driver.

ON

 

 

 

 

 

 

 

ON

 

 

 

1

2

3

4

5

6

7

8

1

2

3

4

 

 

SW1

 

 

 

 

 

SW2

SW3

- 18 -

Image 19
Contents SMC Corporation ・Safety instructions for electric equipment ・Safety instructions for pneumatic equipment・Level of potential hazard ! Caution ・Safety instructions for cables・Safety instructions for power supply Index EX500 Serial System Input / Output Unit Outline Gateway GW UnitSystem Structure Electromagnetic Emission SpecificationTest Procedure Specification Criterion ・EMC Directive 89 / 336 / EECHow to Order 5 0 0 G D N Gateway GW Unit specificationDeviceNet communication specification EX500 GDN1 PROFIBUS-DP EN50170 PROFIBUS-DP communication specification EX500 GPR12. Input Unit Input Unit specificationInput Unit Manifold 1. Input ManifoldHow to Order 5 0 0 I E Input Block specification3. Input Block SI Unit for SV series Manifold Valve SI Unit specificationSI Unit Applicable Manifold Valve seriesOption Electric specificationCommunication Connector Cable for DeviceNet EX500 GDN1 Cable specificationHow to Order 5 0 0 a C 0 3 0 S S P S 2. Branch Cable with M12 Connector4. Terminal Plug 3. Power Supply Connector Cable5. Water Proof Cap ・Representative PLC Parts descriptionDisplay Content Operation settingLED display 2. Operation setting switch SW2 1. Operation setting switch SW1Setting Operation State of SW3 3. Terminating resistance setting switch SW3Layout of scanner I/O Data Rate・Wiring length How to operate EX500 GDN1 DeviceNet Connection style・Cable specification EDO Figure of setting switch 2. Data rate setting switch SW3 1. Address setting switch SW1I/O memory map ・Communication speed and Longest wiring length How to operate EX500 GPR1 PROFIBUS-DP Communication wiring・Terminating resistance DIA State of SW4 1. Address setting switch SW1, 22. Terminating resistance setting switch SW4 ・In case of corresponding with Word・In case of corresponding with Double Word Input Unit Power supply must be reset after fixing the short circuitInput Unit Manifold Parts description Correspondence of input number and Input BlockExploded view / Input Unit Manifold ・Parts list Parts name Parts number・Addition of the Input Block SI Unit for SV series Manifold Manifold Valve Parts descriptionSV series VQC seriesCorrespondence of output number and Manifold Valve SI Unit for SV series Manifold How to install the SI UnitSI Unit for VQC series Manifold Single power supply WiringSource wiring Individual power supplyDeviceNet EX500 GDN1 communication wiring Communication wiring 1. Communication wiring to PLC2. Communication wiring to the SI Unit and the Input Unit Remote I/O EX500 GAB1 -X1 communication wiring・In case of M8 Input Block Dimension 10 -1. Gateway GW Unit 10 -2. Input Unit ManifoldStations ・In case of M12 Input Block 10 -3. Manifold Valve・Whole system Remedies Trouble shooting・Remote I/O communication Remedies Status of NS LED ・DeviceNet communication Remedies・PROFIBUS-DP communication Remedies Status of MS LED