Vixel manual Management, Vixel Model 335 Installation & Configuration Guide, OS Information

Page 24
OS Information

Vixel Model 335 Installation & Configuration Guide

CHAPTER 3 Management

 

 

OS Information

The Ordered Sets Information page displays the Ordered Sets that are being transmitted on the switch by their associated port number.

To view the Ordered Sets Information page:

1.Click FC Switch. The FC Switch Information page appears.

2.Click OS Info. The Ordered Set Information page.

Figure 3-10.Ordered Set Information Page

If there is a connection, then the Ordered Set transmission information for that connection is depicted by an "X".

A list of the Ordered Sets and their indications follows:

Detection
Indication

 

 

Non-Overlap Zone

Displays the zone for which the port is configured.

 

 

Transceiver

Displays the status of the inserted transceiver in the port.

 

 

Sync

A stable signal has been detected and IDLEs transmitted.

 

 

Match

The ordered set or pattern selected under the Match area has

 

been detected.

 

 

EOF

An End-of-Frame (EOF) delimiter has been detected; frames are

 

present on the loop. (An EOF immediately follows the CRC of a

 

frame and signals the frame’s end.)

 

 

SOF

A Start-of-Frame (SOF) delimiter has been detected; frames are

 

present on the loop.

 

 

IDLE

Sequences of IDLEs are being transmitted to maintain link

 

activity; no other data is being transmitted.

 

 

ARBff

ARB(FF)s are being transmitted to maintain link activity; no

 

other data is being transmitted.

 

 

ARB

A port is arbitrating for loop access to perform a task.

 

 

21

Image 24
Contents Managed Storage Switch INSTALLATION&CONFIGURATIONInSpeed Model guidePart Number 00041363-001 Rev. A Table of Contents A p p e n d i x e sFeatures CHAPTER 1 IntroductionAbout This Guide OverviewFibre Channel - Arbitrated Loop InSpeed TechnologyVixel Model 335 Installation & Configuration Guide CHAPTER 1 IntroductionCHAPTER 2 Installation Unpacking the SwitchInstalling the Switch Using Small Form - Factor Pluggable SFP Transceivers Performing a Power On Systems TestSmall Form-Factor Pluggable SFP Installation CHAPTER 2 InstallationSetting Up the Switch Attaching DevicesUnderstanding the Switch’s LEDs Power OnFigure 2-1. Switch features diagram System LEDsCHAPTER 2 Installation System LEDsIndication Port LEDsPort BypassedStatus ActivityCascading Switches Figure 2-4. Cascading Switches in Overlapping ZonesCascading with Non-Overlapping Zones Zone Zone ZoneFigure 2-7. ACCEPTABLE Single Cascade in Zones 2-12 Only Using the Web Manager O v e rv i e wConnecting to the Web Manager CHAPTER 3 ManagementCHAPTER 3 Management NavigationLogging On and Off Figure 3-1. Web Manager Home PageConfiguring the Switch Configuration TaskResetting the Switch Location in Web ManagerSystem Information Settings SettingDescription Figure 3-2. System Information PageNetwork Settings Figure 3-3. System Information Change Settings PageSwitch Speed Switching ModeSwitch Identification Blocking ARBDownloading the Switch Configuration Time SettingsFigure 3-5. Time Information Change Settings Page Figure 3-4. Time Information PageFirmware Settings Figure 3-6. Firmware Information Page1. Click Change Firmware Settings Event Log Messages1. Click Load New Firmware Image Figure 3-7. Event Log Messages PageFC Switch Information Figure 3-8. FC Switch Information PageFigure 3-9. FC Switch Information Page with Highlighted Zones OS Information DetectionIndication Figure 3-10. Ordered Set Information PageRRDY Port Usage Information Figure 3-11. Ordered Set Information Page with Highlighted ZonesFigure 3-12. Received Port Utilization Page Figure 3-14. Received Port Utilization Change Settings Page ValueFigure 3-13. Received Port Utilization Page with Highlighted Zones Port Settings Figure 3-15. Port Information PageFigure 3-16. Port Information Page with Highlighted Zones Figure 3-17. Port Information Page with Transceiver InformationMode Figure 3-18. Cascade Information PageFigure 3-19. Cascade Information Page with Highlighted Zones Policy Settings Switch PolicyFigure 3-20. Policies Page To update the switch’s policies Figure 3-21. Policies Change Settings PageZone Settings Figure 3-22. Overlapping ZonesFigure 3-23. Non-overlapping Zones Figure 3-24. Zone Information PageOverlapping Zones Figure 3-25. Overlapping Zone 1 Information PageFigure 3-26. Overlapping Zone 1 Information Configuration Page Non-Overlapping ZonesFigure 3-28. Non-Overlapping Zones Information Configuration Page Figure 3-27. Non-Overlapping Zone Information PageNote Ports 11 and 12 are always in ZoneHighlighted Zones Using the Command Line Interface CLI Connecting to the CLICLI Command Changing the Switch’s IP Parameters Configuring Switch InformationEnabling or Disabling DHCP Requests Managing the Firmware Downloading New Firmwaretftp -i IPaddress PUT filename ramdisk tftp IPaddressMessage ActionConfiguring the Trap Destination Table Option Changing the CLI/Web Password Viewing Management, Policy, and Threshold SettingsPolicies PolicySettings Threshold InformationOptions 2-Emergency, 3-Alert, 4-Critical, 5-Error, 6-Warning ActionsChanging the Switching Mode CommandVixel Model 335 Installation & Configuration Guide Displaying Ports Vixel Model 335 Installation & Configuration Guide Resetting the Switch Resetting the HardwareResetting the Switch to Factory Default Settings Viewing the Event LogChanging the Switch’s Operating Speed Overlapping Zoning ConfigurationViewing and Understanding Zoning Information Non-Overlapping Zoning Configuration Example noz 25,6,7,8 39,10Reference Technical SupportCHAPTER 4 Technical Tro ub l e sh oo ti n g If the switch’s Fault LED remains lit, the switch requires repairCHAPTER 4 Technical Reference If the Mgmt Present LED continues to blink and POST has alreadyFibre Channel References Small Form-Factor Pluggable SFP IssuesProblem Recommended ActionAppendixes APPENDIX A Specifications S p e c i f i c a t i o n sOperating Conditions APPENDIX A SpecificationsVixel Model 335 Operating Conditions RequirementCommands Console CommandsCommand General CommandsAPPENDIX B CLI Console Commands Action CommandsCommand APPENDIX C Event Messages EventMeaning ActionAPPENDIX C Event Messages Vixel Model 335 Installation & Configuration Guide APPENDIX C Event MessagesEvent MeaningVixel Model 335 Installation & Configuration Guide Cross References Loop ID-ALPAAPPENDIX D Arbitrated Loop Physical AddressesAPPENDIX E Glossary Enables the switch to be divided into separate environments Index Index