Vixel manual Management, Vixel Model 335 Installation & Configuration Guide, Rrdy

Page 25
RRDY

Vixel Model 335 Installation & Configuration Guide

CHAPTER 3 Management

 

 

 

 

 

 

 

RRDY

The receiving node on this port has sent an R_RDY signal,

 

 

indicating that it is ready for a frame to be transmitted over the

 

 

link.

 

 

 

 

CLS

The port is attempting to begin the process of closing the current

 

 

loop circuit.

 

 

 

 

OPN

The port is attempting to open communications with another

 

 

port on the loop. Note: As is the case with some ordered sets, an

 

 

OPN may not go all the way around the loop, instead stopping

 

 

at its destination.

 

 

 

 

LIP F8

A non-switching port has detected a loop failure on its receive

 

 

input, is notifying other ports, and is determining whether the

 

 

loop is still operational.

 

 

Some events that could cause the port to detect loop failure

 

 

follow:

 

 

• A device in the loop has failed.

 

 

• A device in the loop has been powered off.

 

 

• The physical connection between the transmitter and receiver

 

 

is broken.

 

 

• Activating the port bypass circuit does not typically result in a

 

 

loop failure.

 

 

 

 

LIP F7

A loop port is in the non-participating mode and is attempting

 

 

to win arbitration and begin initialization, possibly because the

 

 

port was reset or is powering up. Sometimes the port is sending

 

 

this sequence to another, hot-cascaded switch like a new initiator

 

 

being inserted in the loop.

 

 

 

 

LIP

A Loop Initialization Primitive (LIP) sequence has been detected

 

 

and action has been taken.

 

 

 

 

Unknown

The switch can not determine what is being transmitted.

 

 

 

 

InvTxWd

An invalid transmit word has been detected.

 

 

 

 

CRC Err

A Frame CRC error has been detected.

 

 

 

 

Pt-to-Pt

A point-to-point connection has been detected.

 

 

 

22

Image 25
Contents INSTALLATION&CONFIGURATION Managed Storage SwitchInSpeed Model guidePart Number 00041363-001 Rev. A A p p e n d i x e s Table of ContentsCHAPTER 1 Introduction FeaturesAbout This Guide OverviewInSpeed Technology Fibre Channel - Arbitrated LoopVixel Model 335 Installation & Configuration Guide CHAPTER 1 IntroductionUnpacking the Switch CHAPTER 2 InstallationInstalling the Switch Performing a Power On Systems Test Using Small Form - Factor Pluggable SFP TransceiversSmall Form-Factor Pluggable SFP Installation CHAPTER 2 InstallationAttaching Devices Setting Up the SwitchPower On Understanding the Switch’s LEDsFigure 2-1. Switch features diagram System LEDsSystem LEDs CHAPTER 2 InstallationIndication Port LEDsBypassed PortStatus ActivityFigure 2-4. Cascading Switches in Overlapping Zones Cascading SwitchesCascading with Non-Overlapping Zones Zone Zone ZoneFigure 2-7. ACCEPTABLE Single Cascade in Zones 2-12 Only O v e rv i e w Using the Web ManagerConnecting to the Web Manager CHAPTER 3 ManagementNavigation CHAPTER 3 ManagementLogging On and Off Figure 3-1. Web Manager Home PageConfiguration Task Configuring the SwitchResetting the Switch Location in Web ManagerSetting System Information SettingsDescription Figure 3-2. System Information PageFigure 3-3. System Information Change Settings Page Network SettingsSwitching Mode Switch SpeedSwitch Identification Blocking ARBTime Settings Downloading the Switch ConfigurationFigure 3-5. Time Information Change Settings Page Figure 3-4. Time Information PageFigure 3-6. Firmware Information Page Firmware SettingsEvent Log Messages 1. Click Change Firmware Settings1. Click Load New Firmware Image Figure 3-7. Event Log Messages PageFigure 3-8. FC Switch Information Page FC Switch InformationFigure 3-9. FC Switch Information Page with Highlighted Zones Detection OS InformationIndication Figure 3-10. Ordered Set Information PageRRDY Figure 3-11. Ordered Set Information Page with Highlighted Zones Port Usage InformationFigure 3-12. Received Port Utilization Page Value Figure 3-14. Received Port Utilization Change Settings PageFigure 3-13. Received Port Utilization Page with Highlighted Zones Figure 3-15. Port Information Page Port SettingsFigure 3-17. Port Information Page with Transceiver Information Figure 3-16. Port Information Page with Highlighted ZonesFigure 3-18. Cascade Information Page ModeFigure 3-19. Cascade Information Page with Highlighted Zones Switch Policy Policy SettingsFigure 3-20. Policies Page Figure 3-21. Policies Change Settings Page To update the switch’s policiesFigure 3-22. Overlapping Zones Zone SettingsFigure 3-23. Non-overlapping Zones Figure 3-24. Zone Information PageFigure 3-25. Overlapping Zone 1 Information Page Overlapping ZonesNon-Overlapping Zones Figure 3-26. Overlapping Zone 1 Information Configuration PageFigure 3-27. Non-Overlapping Zone Information Page Figure 3-28. Non-Overlapping Zones Information Configuration PageNote Ports 11 and 12 are always in ZoneHighlighted Zones Connecting to the CLI Using the Command Line Interface CLICLI Command Configuring Switch Information Changing the Switch’s IP ParametersEnabling or Disabling DHCP Requests Downloading New Firmware Managing the Firmwaretftp -i IPaddress PUT filename ramdisk tftp IPaddressAction MessageConfiguring the Trap Destination Table Option Viewing Management, Policy, and Threshold Settings Changing the CLI/Web PasswordPolicy PoliciesThreshold Information SettingsActions Options 2-Emergency, 3-Alert, 4-Critical, 5-Error, 6-WarningCommand Changing the Switching ModeCommand Displaying Ports Setting Resetting the Hardware Resetting the SwitchResetting the Switch to Factory Default Settings Viewing the Event LogOverlapping Zoning Configuration Changing the Switch’s Operating SpeedViewing and Understanding Zoning Information Example noz 25,6,7,8 39,10 Non-Overlapping Zoning ConfigurationTechnical Support ReferenceCHAPTER 4 Technical If the switch’s Fault LED remains lit, the switch requires repair Tro ub l e sh oo ti n gCHAPTER 4 Technical Reference If the Mgmt Present LED continues to blink and POST has alreadySmall Form-Factor Pluggable SFP Issues Fibre Channel ReferencesProblem Recommended ActionAppendixes S p e c i f i c a t i o n s APPENDIX A SpecificationsAPPENDIX A Specifications Operating ConditionsVixel Model 335 Operating Conditions RequirementConsole Commands CommandsCommand General CommandsAction Commands APPENDIX B CLI Console CommandsVixel Model 335 Installation & Configuration Guide Event APPENDIX C Event MessagesMeaning ActionAPPENDIX C Event Messages APPENDIX C Event Messages Vixel Model 335 Installation & Configuration GuideEvent MeaningAPPENDIX C Event Messages Loop ID-ALPA Cross ReferencesAPPENDIX D Arbitrated Loop Physical AddressesAPPENDIX E Glossary Enables the switch to be divided into separate environments Index Index