Vixel Vixel Model 335 Installation & Configuration Guide, APPENDIX C Event Messages, Meaning

Page 67
APPENDIX C Event Messages

Vixel Model 335 Installation & Configuration Guide

APPENDIX C Event Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref

Event

Meaning

 

Action

Severity

 

 

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

132

Zone up then down

The zone state has cycled

 

---

Warning

 

 

 

 

through the “up” and “down”

 

 

 

 

 

 

states several times. Current

 

 

 

 

 

 

zone state (at the time of this

 

 

 

 

 

 

message) is down.

 

 

 

 

 

 

 

 

 

 

 

 

 

133

Zone down then up

The zone state has cycled

 

---

Warning

 

 

 

 

through the “up” and “down”

 

 

 

 

 

 

states several times. Current

 

 

 

 

 

 

zone state (at the time of this

 

 

 

 

 

 

message) is up.

 

 

 

 

 

140

Port inserted

A port was inserted onto the

---

Info

 

 

 

 

zone (after being bypassed).

 

 

 

 

 

 

 

 

 

 

 

141

Port bypassed

A port was bypassed (could not

Check all connections

Info

 

 

 

(LIPF8)

insert) because a LIP(F8) was

for the specified port.

 

 

 

 

 

received at port input. (A

 

 

 

 

 

 

 

LIP(F8) indicates a loop fail-

 

 

 

 

 

 

ure.)

 

 

 

 

 

142

Port bypassed (tx

A port was bypassed because

Contact an authorized

Info

 

 

 

fault)

the switch detected a transmit-

service representative.

 

 

 

 

 

ter fault on the port’s trans-

The transceiver may

 

 

 

 

 

ceiver.

 

need replacing.

 

 

 

 

 

 

 

 

 

 

143

Port bypassed

A port was bypassed (could not

---

Info

 

 

 

(timeout)

insert) because no LIP(F7)s

 

 

 

 

 

 

 

were received after continuous

 

 

 

 

 

 

transmission of LIP(F7)s for

 

 

 

 

 

 

112 milliseconds.

 

 

 

 

 

145

Port bypassed

A port was bypassed for a rea-

---

Info

 

 

 

 

son other than transceiver

 

 

 

 

 

 

 

transmitter fault, invalid

 

 

 

 

 

 

 

response, or manual bypass.

 

 

 

 

 

 

 

 

 

 

 

 

146

Port bypassed then

A port was bypassed, then

 

---

Info

 

 

 

inserted

inserted.

 

 

 

 

 

147

Port inserted then

A port was inserted, then

 

---

Info

 

 

 

bypassed

bypassed.

 

 

 

 

 

 

 

 

 

 

 

 

 

150

Transceiver inserted

A transceiver was inserted.

 

---

Notice

 

 

151

Transceiver removed

A transceiver was removed.

---

Notice

 

 

 

 

 

 

 

 

 

 

160

Management active

Agent is operational.

 

---

Info

 

 

165

Agent task asserted

During normal operations, an

Contact an authorized

Critical

 

 

 

on prev exec cycle

attempt to execute a command

service

 

 

 

 

 

was aborted due to an internal

representative.

 

 

 

 

 

error in the firmware.

 

 

 

 

 

 

 

The switch automatically resets

 

 

 

 

 

 

after the occurrence.

 

 

 

 

 

 

 

 

 

 

 

 

166

Agent machine

A task attempted to execute an

Contact an authorized

Critical

 

 

 

exception on prev

unknown command. The

 

service

 

 

 

 

exec cycle

switch automatically resets

 

representative.

 

 

 

 

 

after the occurrence.

 

 

 

 

 

170

Diagnostic function

A diagnostic setting is miscon-

Check diagnostic set-

Warning

 

 

 

aborted

figured and required a firm-

tings for incompatibili-

 

 

 

 

 

ware override.

 

ties.

 

 

 

 

 

 

 

 

 

 

200

CRC error detected

CRC errors were detected in a

No action required. You

Info

 

 

 

 

frame received on a port.

 

can modify the CRC

 

 

 

 

 

 

 

Error threshold through

 

 

 

 

 

 

 

the Web Manager or

 

 

 

 

 

 

 

CLI interface.

 

 

 

201

CRC error threshold

During the past ten seconds, the

No action required. You

Info

 

 

 

exceeded

number of CRC errors in

 

can modify the Error

 

 

 

 

 

frames received by the specified

Count threshold through

 

 

 

 

 

port exceeded the current

 

the Web Manager or

 

 

 

 

 

threshold value.

 

CLI interface.

 

 

 

 

 

 

 

 

 

 

202

OS Error threshold

During the past ten seconds, the

No action required. You

Info

 

 

 

exceeded

number of OS errors (invalid

can modify the Error

 

 

 

 

 

transmit words, or 8b/10b

 

Count threshold through

 

 

 

 

 

encoding errors) in frames

 

the Web Manager or

 

 

 

 

 

received by the specified port

CLI interface.

 

 

 

 

 

exceeded the current threshold

 

 

 

 

 

 

value.

 

 

 

 

 

 

 

 

 

 

 

 

64

Image 67
Contents guide Managed Storage SwitchINSTALLATION&CONFIGURATION InSpeed ModelPart Number 00041363-001 Rev. A A p p e n d i x e s Table of ContentsOverview FeaturesCHAPTER 1 Introduction About This GuideCHAPTER 1 Introduction Fibre Channel - Arbitrated LoopInSpeed Technology Vixel Model 335 Installation & Configuration GuideUnpacking the Switch CHAPTER 2 InstallationInstalling the Switch CHAPTER 2 Installation Using Small Form - Factor Pluggable SFP TransceiversPerforming a Power On Systems Test Small Form-Factor Pluggable SFP InstallationAttaching Devices Setting Up the SwitchSystem LEDs Understanding the Switch’s LEDsPower On Figure 2-1. Switch features diagramPort LEDs CHAPTER 2 InstallationSystem LEDs IndicationActivity PortBypassed StatusZone Zone Zone Cascading SwitchesFigure 2-4. Cascading Switches in Overlapping Zones Cascading with Non-Overlapping ZonesFigure 2-7. ACCEPTABLE Single Cascade in Zones 2-12 Only CHAPTER 3 Management Using the Web ManagerO v e rv i e w Connecting to the Web ManagerFigure 3-1. Web Manager Home Page CHAPTER 3 ManagementNavigation Logging On and OffLocation in Web Manager Configuring the SwitchConfiguration Task Resetting the SwitchFigure 3-2. System Information Page System Information SettingsSetting DescriptionFigure 3-3. System Information Change Settings Page Network SettingsBlocking ARB Switch SpeedSwitching Mode Switch IdentificationFigure 3-4. Time Information Page Downloading the Switch ConfigurationTime Settings Figure 3-5. Time Information Change Settings PageFigure 3-6. Firmware Information Page Firmware SettingsFigure 3-7. Event Log Messages Page 1. Click Change Firmware SettingsEvent Log Messages 1. Click Load New Firmware ImageFigure 3-8. FC Switch Information Page FC Switch InformationFigure 3-9. FC Switch Information Page with Highlighted Zones Figure 3-10. Ordered Set Information Page OS InformationDetection IndicationRRDY Figure 3-11. Ordered Set Information Page with Highlighted Zones Port Usage InformationFigure 3-12. Received Port Utilization Page Value Figure 3-14. Received Port Utilization Change Settings PageFigure 3-13. Received Port Utilization Page with Highlighted Zones Figure 3-15. Port Information Page Port SettingsFigure 3-17. Port Information Page with Transceiver Information Figure 3-16. Port Information Page with Highlighted ZonesFigure 3-18. Cascade Information Page ModeFigure 3-19. Cascade Information Page with Highlighted Zones Switch Policy Policy SettingsFigure 3-20. Policies Page Figure 3-21. Policies Change Settings Page To update the switch’s policiesFigure 3-24. Zone Information Page Zone SettingsFigure 3-22. Overlapping Zones Figure 3-23. Non-overlapping ZonesFigure 3-25. Overlapping Zone 1 Information Page Overlapping ZonesNon-Overlapping Zones Figure 3-26. Overlapping Zone 1 Information Configuration Pagealways in Zone Figure 3-28. Non-Overlapping Zones Information Configuration PageFigure 3-27. Non-Overlapping Zone Information Page Note Ports 11 and 12 areHighlighted Zones Connecting to the CLI Using the Command Line Interface CLICLI Command Configuring Switch Information Changing the Switch’s IP ParametersEnabling or Disabling DHCP Requests tftp IPaddress Managing the FirmwareDownloading New Firmware tftp -i IPaddress PUT filename ramdiskAction MessageConfiguring the Trap Destination Table Option Viewing Management, Policy, and Threshold Settings Changing the CLI/Web PasswordPolicy PoliciesThreshold Information SettingsActions Options 2-Emergency, 3-Alert, 4-Critical, 5-Error, 6-WarningCommand Changing the Switching ModeDescription Displaying Ports Description Viewing the Event Log Resetting the SwitchResetting the Hardware Resetting the Switch to Factory Default SettingsOverlapping Zoning Configuration Changing the Switch’s Operating SpeedViewing and Understanding Zoning Information Example noz 25,6,7,8 39,10 Non-Overlapping Zoning ConfigurationTechnical Support ReferenceCHAPTER 4 Technical If the Mgmt Present LED continues to blink and POST has already Tro ub l e sh oo ti n gIf the switch’s Fault LED remains lit, the switch requires repair CHAPTER 4 Technical ReferenceRecommended Action Fibre Channel ReferencesSmall Form-Factor Pluggable SFP Issues ProblemAppendixes S p e c i f i c a t i o n s APPENDIX A SpecificationsRequirement Operating ConditionsAPPENDIX A Specifications Vixel Model 335 Operating ConditionsGeneral Commands CommandsConsole Commands CommandAction Commands APPENDIX B CLI Console CommandsSyntax Action APPENDIX C Event MessagesEvent MeaningAPPENDIX C Event Messages Meaning Vixel Model 335 Installation & Configuration GuideAPPENDIX C Event Messages EventMeaning Arbitrated Loop Physical Addresses Cross ReferencesLoop ID-ALPA APPENDIX DAPPENDIX E Glossary Enables the switch to be divided into separate environments Index Index