Vixel manual Tro ub l e sh oo ti n g, Vixel Model 335 Installation & Configuration Guide

Page 58
CHAPTER 4 Technical Reference

Vixel Model 335 Installation & Configuration Guide

CHAPTER 4 Technical Reference

 

 

Tro ub l e sh oo ti n g

Some common troubleshooting situations are listed below with suggested courses of action.

Situation*

Recommended Action

 

 

No LEDs are on.

Make sure that the switch is plugged into an adequate AC power

source (shown in “Operating Conditions” on page 59).

 

 

 

 

Cycle power to the switch.

The switch’s Fault

One or more enclosure fans may have failed, or an over-temperature

condition may exist. Contact an authorized service person.

LED is on.

If the switch’s Fault LED remains lit, the switch requires repair.

 

 

Contact an authorized service person.

 

 

The Mgmt Present

Contact an authorized service person.

LED is off.

 

 

 

The Mgmt Present

Power cycle the switch to see if the condition clears.

If the Mgmt Present LED continues to blink (and POST has already

LED is blinking

completed), firmware may be corrupt or hardware may have failed.

continuously.

Contact an authorized service person.

 

 

 

 

Check the following items:

The Enet Active LED

• Ethernet RJ-45 connection to the Vixel 335 Managed Storage

Switch.

is off during an

• Ethernet connection to the Ethernet switch.

ethernet connection.

• Power status of the Ethernet switch.

 

 

• Power status of the Vixel 335 Managed Storage Switch.

 

 

 

Check the following items:

 

• Ports (LEDs and SFPs).

The Switch Op LED is

• Cabling.

off or flashing.

• Bad / misbehaving HBA / FC controller at the node end.

 

Note: The switch automatically recovers all zones for the most

 

common failure conditions.

 

 

* LEDs that are on are illuminated; LEDs that are off are extinguished.

55

Image 58
Contents InSpeed Model Managed Storage SwitchINSTALLATION&CONFIGURATION guidePart Number 00041363-001 Rev. A Table of Contents A p p e n d i x e sAbout This Guide FeaturesCHAPTER 1 Introduction OverviewVixel Model 335 Installation & Configuration Guide Fibre Channel - Arbitrated LoopInSpeed Technology CHAPTER 1 IntroductionUnpacking the Switch CHAPTER 2 InstallationInstalling the Switch Small Form-Factor Pluggable SFP Installation Using Small Form - Factor Pluggable SFP TransceiversPerforming a Power On Systems Test CHAPTER 2 InstallationSetting Up the Switch Attaching DevicesFigure 2-1. Switch features diagram Understanding the Switch’s LEDsPower On System LEDsIndication CHAPTER 2 InstallationSystem LEDs Port LEDsStatus PortBypassed ActivityCascading with Non-Overlapping Zones Cascading SwitchesFigure 2-4. Cascading Switches in Overlapping Zones Zone Zone ZoneFigure 2-7. ACCEPTABLE Single Cascade in Zones 2-12 Only Connecting to the Web Manager Using the Web ManagerO v e rv i e w CHAPTER 3 ManagementLogging On and Off CHAPTER 3 ManagementNavigation Figure 3-1. Web Manager Home PageResetting the Switch Configuring the SwitchConfiguration Task Location in Web ManagerDescription System Information SettingsSetting Figure 3-2. System Information PageNetwork Settings Figure 3-3. System Information Change Settings PageSwitch Identification Switch SpeedSwitching Mode Blocking ARBFigure 3-5. Time Information Change Settings Page Downloading the Switch ConfigurationTime Settings Figure 3-4. Time Information PageFirmware Settings Figure 3-6. Firmware Information Page1. Click Load New Firmware Image 1. Click Change Firmware SettingsEvent Log Messages Figure 3-7. Event Log Messages PageFigure 3-8. FC Switch Information Page FC Switch InformationFigure 3-9. FC Switch Information Page with Highlighted Zones Indication OS InformationDetection Figure 3-10. Ordered Set Information PageRRDY Figure 3-11. Ordered Set Information Page with Highlighted Zones Port Usage InformationFigure 3-12. Received Port Utilization Page Value Figure 3-14. Received Port Utilization Change Settings PageFigure 3-13. Received Port Utilization Page with Highlighted Zones Port Settings Figure 3-15. Port Information PageFigure 3-16. Port Information Page with Highlighted Zones Figure 3-17. Port Information Page with Transceiver InformationMode Figure 3-18. Cascade Information PageFigure 3-19. Cascade Information Page with Highlighted Zones Switch Policy Policy SettingsFigure 3-20. Policies Page To update the switch’s policies Figure 3-21. Policies Change Settings PageFigure 3-23. Non-overlapping Zones Zone SettingsFigure 3-22. Overlapping Zones Figure 3-24. Zone Information PageOverlapping Zones Figure 3-25. Overlapping Zone 1 Information PageFigure 3-26. Overlapping Zone 1 Information Configuration Page Non-Overlapping ZonesNote Ports 11 and 12 are Figure 3-28. Non-Overlapping Zones Information Configuration PageFigure 3-27. Non-Overlapping Zone Information Page always in ZoneHighlighted Zones Using the Command Line Interface CLI Connecting to the CLICLI Command Configuring Switch Information Changing the Switch’s IP ParametersEnabling or Disabling DHCP Requests tftp -i IPaddress PUT filename ramdisk Managing the FirmwareDownloading New Firmware tftp IPaddressMessage ActionConfiguring the Trap Destination Table Option Changing the CLI/Web Password Viewing Management, Policy, and Threshold SettingsPolicies PolicySettings Threshold InformationOptions 2-Emergency, 3-Alert, 4-Critical, 5-Error, 6-Warning ActionsChanging the Switching Mode CommandCHAPTER 3 Management Displaying Ports CHAPTER 3 Management Resetting the Switch to Factory Default Settings Resetting the SwitchResetting the Hardware Viewing the Event LogOverlapping Zoning Configuration Changing the Switch’s Operating SpeedViewing and Understanding Zoning Information Non-Overlapping Zoning Configuration Example noz 25,6,7,8 39,10Technical Support ReferenceCHAPTER 4 Technical CHAPTER 4 Technical Reference Tro ub l e sh oo ti n gIf the switch’s Fault LED remains lit, the switch requires repair If the Mgmt Present LED continues to blink and POST has alreadyProblem Fibre Channel ReferencesSmall Form-Factor Pluggable SFP Issues Recommended ActionAppendixes APPENDIX A Specifications S p e c i f i c a t i o n sVixel Model 335 Operating Conditions Operating ConditionsAPPENDIX A Specifications RequirementCommand CommandsConsole Commands General CommandsAPPENDIX B CLI Console Commands Action CommandsAPPENDIX B CLI Console Commands Meaning APPENDIX C Event MessagesEvent ActionAPPENDIX C Event Messages Event Vixel Model 335 Installation & Configuration GuideAPPENDIX C Event Messages MeaningEvent APPENDIX D Cross ReferencesLoop ID-ALPA Arbitrated Loop Physical AddressesAPPENDIX E Glossary Enables the switch to be divided into separate environments Index Index
Related manuals
Manual 74 pages 3.33 Kb