Message

Vixel Model 335 Installation & Configuration Guide

CHAPTER 3 Management

 

 

Note: To cancel out of the file transfer facility, press CTRL+X several times.

d.Type the following and press Enter. quit

4.In the terminal session window, type 1 to verify and store the new firmware. The following message appears.

Clearing backup host filename.. Clearing backup host IP address.. Verifying file integrity.. Erasing flash memory.. Programming flash memory.. Verifying..

*PROGRAM LOAD SUCCESSFUL*

Type fw, then type 1.

The active and alternate firmware versions are displayed.

5.If the “alternate version” is anything other than the firmware you just downloaded, verify that the file is good and repeat the download.

6.If you want to activate the alternate version (the newly downloaded firmware):

a.Type 2 to select the alternate version for execution on the next boot cycle.

b.Type 1 to verify that the following message is displayed under the firmware versions: “Note: ALTERNATE selected for execution on next boot cycle.” (If this message is not displayed, repeat steps a and b to toggle back.)

c.Type 5 to reboot.

The management agent disconnects, reboots, and activates the downloaded firmware. The “Disconnecting and Rebooting” message appears.

The firmware is downloaded.

Serial Method (Menu Option 4)

The Serial method for downloading firmware is available for Windows only.

1.Ensure that the switch and workstation are connected through a serial null modem cable.

2.Type 4.

The file transfer facility appears.

3.Choose Send File from the Transfer pull-down menu in HyperTerminal. The Send File dialog box appears.

4.Type (or browse for) the filename, select “1K Xmodem” from the Protocol drop- down list, and click Send.

A status message appears.

5.If the status message says anything other than “File transfer completed,” perform the action recommended for the appropriate message shown below.

Message

Action

 

 

CRC Error

Try another file. The file you are attempting to download may be corrupted.

 

 

Time out error

Cycle power to the switch and retry the download procedure.

 

 

Access denied

Close and reestablish the connection. Cycle power to the switch and retry the

 

download procedure.

 

 

40

Image 43
Contents guide Managed Storage SwitchINSTALLATION&CONFIGURATION InSpeed ModelPart Number 00041363-001 Rev. A A p p e n d i x e s Table of ContentsOverview FeaturesCHAPTER 1 Introduction About This GuideCHAPTER 1 Introduction Fibre Channel - Arbitrated LoopInSpeed Technology Vixel Model 335 Installation & Configuration GuideUnpacking the Switch CHAPTER 2 InstallationInstalling the Switch CHAPTER 2 Installation Using Small Form - Factor Pluggable SFP TransceiversPerforming a Power On Systems Test Small Form-Factor Pluggable SFP InstallationAttaching Devices Setting Up the SwitchSystem LEDs Understanding the Switch’s LEDsPower On Figure 2-1. Switch features diagramPort LEDs CHAPTER 2 InstallationSystem LEDs IndicationActivity PortBypassed StatusZone Zone Zone Cascading SwitchesFigure 2-4. Cascading Switches in Overlapping Zones Cascading with Non-Overlapping ZonesFigure 2-7. ACCEPTABLE Single Cascade in Zones 2-12 Only CHAPTER 3 Management Using the Web ManagerO v e rv i e w Connecting to the Web ManagerFigure 3-1. Web Manager Home Page CHAPTER 3 ManagementNavigation Logging On and OffLocation in Web Manager Configuring the SwitchConfiguration Task Resetting the SwitchFigure 3-2. System Information Page System Information SettingsSetting DescriptionFigure 3-3. System Information Change Settings Page Network SettingsBlocking ARB Switch SpeedSwitching Mode Switch IdentificationFigure 3-4. Time Information Page Downloading the Switch ConfigurationTime Settings Figure 3-5. Time Information Change Settings PageFigure 3-6. Firmware Information Page Firmware SettingsFigure 3-7. Event Log Messages Page 1. Click Change Firmware SettingsEvent Log Messages 1. Click Load New Firmware ImageFigure 3-8. FC Switch Information Page FC Switch InformationFigure 3-9. FC Switch Information Page with Highlighted Zones Figure 3-10. Ordered Set Information Page OS InformationDetection IndicationRRDY Figure 3-11. Ordered Set Information Page with Highlighted Zones Port Usage InformationFigure 3-12. Received Port Utilization Page Value Figure 3-14. Received Port Utilization Change Settings PageFigure 3-13. Received Port Utilization Page with Highlighted Zones Figure 3-15. Port Information Page Port SettingsFigure 3-17. Port Information Page with Transceiver Information Figure 3-16. Port Information Page with Highlighted ZonesFigure 3-18. Cascade Information Page ModeFigure 3-19. Cascade Information Page with Highlighted Zones Switch Policy Policy SettingsFigure 3-20. Policies Page Figure 3-21. Policies Change Settings Page To update the switch’s policiesFigure 3-24. Zone Information Page Zone SettingsFigure 3-22. Overlapping Zones Figure 3-23. Non-overlapping ZonesFigure 3-25. Overlapping Zone 1 Information Page Overlapping ZonesNon-Overlapping Zones Figure 3-26. Overlapping Zone 1 Information Configuration Pagealways in Zone Figure 3-28. Non-Overlapping Zones Information Configuration PageFigure 3-27. Non-Overlapping Zone Information Page Note Ports 11 and 12 areHighlighted Zones Connecting to the CLI Using the Command Line Interface CLICLI Command Configuring Switch Information Changing the Switch’s IP ParametersEnabling or Disabling DHCP Requests tftp IPaddress Managing the FirmwareDownloading New Firmware tftp -i IPaddress PUT filename ramdiskAction MessageConfiguring the Trap Destination Table Option Viewing Management, Policy, and Threshold Settings Changing the CLI/Web PasswordPolicy PoliciesThreshold Information SettingsActions Options 2-Emergency, 3-Alert, 4-Critical, 5-Error, 6-WarningCommand Changing the Switching ModeDescription Displaying Ports Description Viewing the Event Log Resetting the SwitchResetting the Hardware Resetting the Switch to Factory Default SettingsOverlapping Zoning Configuration Changing the Switch’s Operating SpeedViewing and Understanding Zoning Information Example noz 25,6,7,8 39,10 Non-Overlapping Zoning ConfigurationTechnical Support ReferenceCHAPTER 4 Technical If the Mgmt Present LED continues to blink and POST has already Tro ub l e sh oo ti n gIf the switch’s Fault LED remains lit, the switch requires repair CHAPTER 4 Technical ReferenceRecommended Action Fibre Channel ReferencesSmall Form-Factor Pluggable SFP Issues ProblemAppendixes S p e c i f i c a t i o n s APPENDIX A SpecificationsRequirement Operating ConditionsAPPENDIX A Specifications Vixel Model 335 Operating ConditionsGeneral Commands CommandsConsole Commands CommandAction Commands APPENDIX B CLI Console CommandsSyntax Action APPENDIX C Event MessagesEvent MeaningAPPENDIX C Event Messages Meaning Vixel Model 335 Installation & Configuration GuideAPPENDIX C Event Messages EventMeaning Arbitrated Loop Physical Addresses Cross ReferencesLoop ID-ALPA APPENDIX DAPPENDIX E Glossary Enables the switch to be divided into separate environments Index Index