2.1.5.4 Dip Switches

To change the DIP switches, follow the instructions below:

1. The unit should be removed from the panel and opened.

Refer to Section 2.1.4.3 for assembly and disassembly instructions.

2. Locate the 4 and 8 position DIP switches, on the top board. The Meter is shipped with all DIP switches in "OFF" position

To set the Wireless and Ethernet settings to Factory Default, Refer to Section 7.

S1 1

8

OFF

1

 

8

ON

OFF

 

ON

ON

8 Position

DIP Switch on

Wireless Board

1 To change the Wireless settings to Factory Default

2-8 N/A

4 3 2 OFF 1

 

 

4

3 2

1

 

 

 

 

 

4 Position

 

 

OFF

 

 

 

 

 

DIP Switch on

ON

 

 

 

Ethernet Board

 

 

1

 

 

 

N/A

 

 

 

2

To change the Ethernet settings to

3

Factory Default

 

 

 

To enable/disable DHCP

 

4

N/A

 

 

 

Figure 2.11 Location of DIP Switches

15

Image 21
Contents User’sGuide Page Table of Contents List of Figures 19a List of Tables Part Introduction Safety ConsiderationsBefore You Begin Customer ServiceDescription Inspecting Your ShipmentDescription Rockwell Automation, and National Instruments, among others Front Panel Enunciators Physical Characteristics and Mounting 2.1.1 Front PanelRear Panel Connector Rear PanelNetwork Mounting Dimensions DimensionsPanel Mounting Assembly and Mounting 2.1.4.1 Panel Mounting InstructionAntenna Mounting Antenna Mounting InstructionAccessing the Main Board Assembly Disassembly InstructionUse copper conductors only for power connections Electrical Installation Power ConnectionsOutputs Wiring Hookup Wiring OutputsOutputs Wiring Hookup Pulse and AnalogFast Blow Typical Applications10 Location of S1 Jumper Jumper Settings for Display Color SetupPosition Dip SwitchesPin Name Description Network Communication Interfaces 1 10Base-T RJ-45 PinoutEthernet MAC Address Network Protocols .1 Label DetailDhcp DNS 4 Position DIP SwitchIP Address Default IP AddressSection Changing TCP/IP Properties on Your ComputerPinging the Meter from MS-DOS Prompt Testing the ConnectionIConnect Software Assigning an IP Address using iConnectWireless Sensor Home Access Control Setting a New IP Address over the NetworkWireless System Home Page Menu Meter’s Configurations and OperationsPower Up Meter Login AdministratorLab Get Readings from the End DeviceGet Readings from the End Device ID End Device ID/address Java 1.5.x.x. Screen Shots Java Runtime Environment Setup10 Java 1.4.2.x Screen Shot Java Runtime Environment 1.4 Setup InstructionsAccessing Meter units using the internet Accessing Meter units within your internal networkDiagnostics Accessing Meter units over Peer-to-Peer network11 Java Policy Java Policy12 Java Policy Djava.security.policy=C\0JAVAPOLICY\javapolicy.txt13 Chart ChartChart 14 Controller Setup Controller SetupTransmission Power SetupMonitor MiscellaneousInput SetupSetpoints & On/Off Control Setpoints & On/Off Control Alarms 1 Setup Analog Output Retransmission Setup19a Display Menu Display19b Display Menu if Analog Output Option Example Display Color ExamplesAmber 20 ID Code Passcode IDRemote Access Tunneling Network SetupGeneral Terminal ServerRemote Access GeneralTerminal Server 22 End Device Setup End Device SetupEnd Device Parameters Sensor2 Sensor1T75F T74F SensorUpdate CancelDisplay Access Control Telnet Setup List of Ascii / Telnet Commands 01 indicates End Device #1Command Description Response HTTPget Program HTTPget using PortHTTPget and ARP to Setup Device IP Address Connector/Transmitter TypesARP Protocol 27 ARP Commands and Responses28 iLog Software Logging Data for End Device #2, 6 ILog SoftwareILog Software ILog Excel Applications Wireless DevicesNetworked Product ILog File Alternate Networked Product Auto FullMail Notifier Software InstallationEmail Setup Email Address SetupMail Notifier Commands Device Setting and ConfigurationAlarm Editor General Deployment Guidelines Environment / Operating ConditionsOperation in Buildings Distance feet With Line-of-SightCasing and Closure Around the Antenna Without Line-of-SightMaterial Type See .1.4.2 and FigurePart Specifications General Safety & Regulatory Compliance Input Factory Preset ValuesFactory Preset Values Setpoints & On/Off Control AlarmPasscode ID Remote Access Tunneling Factory Preset Values Analog Output RetransmissionAccess Control MiscEnd Device # 1 Factory Preset Values End Device SetupAppendix Aglossary Appendix BIP Address Address Class Mask Binary Value Mask Decimal Value Ascii Dec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Maximum Power Levels and Antenna Gains WARRANTY/DISCLAIMER PH/CONDUCTIVITY Shop on line at omega.com