Omega WI8XX-U manual Connector/Transmitter Types, HTTPget and ARP to Setup Device IP Address

Page 65

where:

-r–Sare parameters needed for the the command string Command (See Table 4.1)

192.168.1.135 is an IP address 2000 is a socket port number

-C1closes the TCP connection after 1 second

-qdisplays no error messages once the connection is closed

 

 

 

Figure 4.26 HTTPget Example of Polling End Device #2,6,7

Table 4.2 Connector/Transmitter Types

 

 

 

 

 

UWTC B Type TC

221

 

 

UWTC K Type TC

230

 

 

 

 

 

 

 

 

 

UWTC C Type TC

222

 

 

UWTC N Type TC

233

 

 

 

 

UWTC E Type TC

224

 

 

UWRTD

235

 

 

 

 

UWIR

228

 

 

UWTC R Type TC

237

 

 

 

 

UWTC J Type TC

229

 

 

UWTC S Type TC

238

 

 

 

 

 

 

 

 

UWTC T Type TC

239

 

4.5.2 HTTPget and ARP to Setup Device IP Address

 

 

 

 

 

Use the iConnect software, which may be downloaded from our website,

 

 

 

to do these IP changes whenever possible.

 

 

 

 

 

 

 

Use ARP first to assign the mac address to a static IP address in computer arp

table by this command:

 

 

 

 

 

 

arp –s 192.168.1.200 00-03-34-00-06-b6

 

 

 

Then use the following command to assign new IP to the device:

 

 

Httpget –r –S "00000000" 192.168.1.200:1

 

 

where:

 

 

 

 

 

 

"0000000" is admin. password. If the password is wrong, the unit will ignore the

new IP. If the new IP is taken, you will get the message "New IP is Assigned"

after the HTTPget command. The device will reset automatically.

 

 

"192.168.1.200" is an example of an IP address. It is replaced with IP address

suitable for your network

 

 

 

 

 

 

"00-03-34-00-06-b6" is replaced with your Meter’s MAC address.

 

 

 

 

 

 

59

 

 

 

Image 65
Contents User’sGuide Page Table of Contents List of Figures 19a List of Tables Part Introduction Safety ConsiderationsBefore You Begin Customer ServiceDescription Inspecting Your ShipmentDescription Rockwell Automation, and National Instruments, among others Front Panel Enunciators Physical Characteristics and Mounting 2.1.1 Front PanelNetwork Rear Panel ConnectorRear Panel Mounting Dimensions DimensionsPanel Mounting Assembly and Mounting 2.1.4.1 Panel Mounting InstructionAntenna Mounting Antenna Mounting InstructionAccessing the Main Board Assembly Disassembly InstructionUse copper conductors only for power connections Electrical Installation Power ConnectionsOutputs Wiring Hookup Wiring OutputsOutputs Wiring Hookup Pulse and AnalogFast Blow Typical Applications10 Location of S1 Jumper Jumper Settings for Display Color SetupPosition Dip SwitchesPin Name Description Network Communication Interfaces 1 10Base-T RJ-45 PinoutDhcp Ethernet MAC AddressNetwork Protocols .1 Label Detail DNS 4 Position DIP SwitchIP Address Default IP AddressSection Changing TCP/IP Properties on Your ComputerPinging the Meter from MS-DOS Prompt Testing the ConnectionIConnect Software Assigning an IP Address using iConnectWireless Sensor Home Access Control Setting a New IP Address over the NetworkWireless System Home Page Menu Meter’s Configurations and OperationsPower Up Meter Login AdministratorLab Get Readings from the End DeviceGet Readings from the End Device ID End Device ID/address Java 1.5.x.x. Screen Shots Java Runtime Environment Setup10 Java 1.4.2.x Screen Shot Java Runtime Environment 1.4 Setup InstructionsAccessing Meter units using the internet Accessing Meter units within your internal networkDiagnostics Accessing Meter units over Peer-to-Peer network11 Java Policy Java Policy12 Java Policy Djava.security.policy=C\0JAVAPOLICY\javapolicy.txt13 Chart ChartChart 14 Controller Setup Controller SetupTransmission Power SetupMonitor MiscellaneousInput SetupSetpoints & On/Off Control Setpoints & On/Off Control Alarms 1 Setup Analog Output Retransmission Setup19a Display Menu Display19b Display Menu if Analog Output Option Example Display Color ExamplesAmber 20 ID Code Passcode IDRemote Access Tunneling Network SetupGeneral Terminal ServerTerminal Server Remote AccessGeneral 22 End Device Setup End Device SetupEnd Device Parameters Sensor2 Sensor1T75F T74F SensorDisplay UpdateCancel Access Control Command Description Response Telnet SetupList of Ascii / Telnet Commands 01 indicates End Device #1 HTTPget Program HTTPget using PortHTTPget and ARP to Setup Device IP Address Connector/Transmitter TypesARP Protocol 27 ARP Commands and Responses28 iLog Software Logging Data for End Device #2, 6 ILog SoftwareILog Software ILog Excel Applications Wireless DevicesNetworked Product ILog File Alternate Networked Product Auto FullMail Notifier Software InstallationEmail Setup Email Address SetupMail Notifier Commands Device Setting and ConfigurationAlarm Editor General Deployment Guidelines Environment / Operating ConditionsOperation in Buildings Distance feet With Line-of-SightCasing and Closure Around the Antenna Without Line-of-SightMaterial Type See .1.4.2 and FigurePart Specifications General Safety & Regulatory Compliance Input Factory Preset ValuesPasscode ID Factory Preset Values Setpoints & On/Off ControlAlarm Remote Access Tunneling Factory Preset Values Analog Output RetransmissionAccess Control MiscEnd Device # 1 Factory Preset Values End Device SetupAppendix Aglossary Appendix BIP Address Address Class Mask Binary Value Mask Decimal Value Ascii Dec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Maximum Power Levels and Antenna Gains WARRANTY/DISCLAIMER PH/CONDUCTIVITY Shop on line at omega.com