4.3.4

Java Policy

To activate data logging and save graphs from the Java applets, it is necessary

to create a Java Policy file and copy it onto a folder.

1)

Open a Notepad file and using the IP address of the Meter type the

 

 

following:

grant codeBase "http://192.168.1.200/"

{

permission java.security.AllPermission "*", "*";

};

This file should have the IP address of the Meter; in this case the default

 

 

IP address is 192.168.1.200. If the IP address is changed, then the IP

 

 

 

 

address shown in the file needs to be changed; otherwise, it will not work.

 

 

If more than one Meter is being monitored from the same computer, it is

 

 

necessary to repeat the above for each of the Meters in the same

 

 

"java_policy.txt" file.

If DHCP/DNS is enabled, the unique Meter’s name using DNS should replace

the IP address. Example: "http:\\zSrvTEST". Make sure the DHCP server

updates the DNS table to keep track of the Meter’s name and IP addresses

(consult with your network administrator).

2)

Save the file as java_policy.txt.

3)

Create a folder in your C: drive called "0_JAVAPOLICY".

4)

Place the java.policy.policy file into the "0_JAVAPOLICY" folder.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4.11 Java Policy

32

Image 38
Contents User’sGuide Page Table of Contents List of Figures 19a List of Tables Safety Considerations Part IntroductionDescription Customer ServiceBefore You Begin Inspecting Your ShipmentDescription Rockwell Automation, and National Instruments, among others Physical Characteristics and Mounting 2.1.1 Front Panel Front Panel EnunciatorsNetwork Rear Panel ConnectorRear Panel Dimensions Mounting DimensionsAssembly and Mounting 2.1.4.1 Panel Mounting Instruction Panel MountingAntenna Mounting Instruction Antenna MountingDisassembly Instruction Accessing the Main Board AssemblyElectrical Installation Power Connections Use copper conductors only for power connectionsOutputs Wiring Hookup Wiring OutputsOutputs Wiring Hookup Pulse and AnalogTypical Applications Fast BlowJumper Settings for Display Color Setup 10 Location of S1 JumperDip Switches PositionNetwork Communication Interfaces 1 10Base-T RJ-45 Pinout Pin Name DescriptionDhcp Ethernet MAC AddressNetwork Protocols .1 Label Detail 4 Position DIP Switch DNSDefault IP Address IP AddressChanging TCP/IP Properties on Your Computer SectionTesting the Connection Pinging the Meter from MS-DOS PromptAssigning an IP Address using iConnect IConnect SoftwareWireless Sensor Home Setting a New IP Address over the Network Access ControlMeter’s Configurations and Operations Wireless System Home Page MenuLogin Administrator Power Up MeterGet Readings from the End Device LabGet Readings from the End Device ID End Device ID/address Java Runtime Environment Setup Java 1.5.x.x. Screen ShotsJava Runtime Environment 1.4 Setup Instructions 10 Java 1.4.2.x Screen ShotDiagnostics Accessing Meter units within your internal networkAccessing Meter units using the internet Accessing Meter units over Peer-to-Peer networkJava Policy 11 Java PolicyDjava.security.policy=C\0JAVAPOLICY\javapolicy.txt 12 Java PolicyChart 13 ChartChart Controller Setup 14 Controller SetupMonitor SetupTransmission Power MiscellaneousSetup InputSetpoints & On/Off Control Setpoints & On/Off Control Alarms 1 Setup Setup Analog Output RetransmissionDisplay 19a Display Menu19b Display Menu if Analog Output Option Display Color Examples ExampleAmber Passcode ID 20 ID CodeGeneral Network SetupRemote Access Tunneling Terminal ServerTerminal Server Remote AccessGeneral End Device Setup 22 End Device SetupEnd Device Parameters Sensor1 Sensor2Sensor T75F T74FDisplay UpdateCancel Access Control Command Description Response Telnet SetupList of Ascii / Telnet Commands 01 indicates End Device #1 HTTPget using Port HTTPget ProgramConnector/Transmitter Types HTTPget and ARP to Setup Device IP Address27 ARP Commands and Responses ARP ProtocolILog Software 28 iLog Software Logging Data for End Device #2, 6Networked Product ILog File Alternate Wireless DevicesILog Software ILog Excel Applications Networked Product Auto FullInstallation Mail Notifier SoftwareEmail Address Setup Email SetupDevice Setting and Configuration Mail Notifier CommandsAlarm Editor Environment / Operating Conditions General Deployment GuidelinesOperation in Buildings With Line-of-Sight Distance feetMaterial Type Without Line-of-SightCasing and Closure Around the Antenna See .1.4.2 and FigurePart Specifications General Safety & Regulatory Compliance Factory Preset Values InputPasscode ID Factory Preset Values Setpoints & On/Off ControlAlarm Access Control Factory Preset Values Analog Output RetransmissionRemote Access Tunneling MiscFactory Preset Values End Device Setup End Device # 1Appendix Aglossary Appendix BIP Address Address Class Mask Binary Value Mask Decimal Value Ascii Dec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Maximum Power Levels and Antenna Gains WARRANTY/DISCLAIMER Shop on line at omega.com PH/CONDUCTIVITY