Omega WI8XX-U manual Setting a New IP Address over the Network, Access Control

Page 30

4.2 Setting a New IP Address over the Network

Besides using the iConnect software, you may use the Meter’s default IP address to access it and assign a new IP address to it.

The Meter is shipped with a default IP address of 192.168.1.200 and Subnet Mask of 255.255.255.0. You can configure your PC’s Network connection with an IP address that is in the same range as the Meter’s IP address (192.168.1.x) and connect to the Meter using a crossover network cable between your PC and the Meter.

With this completed, you can go to the DOS-Prompt and ping 192.168.1.200. If you receive responses back (Figure 4.1), you can go to the Web browser and type in http://192.168.1.200 and it will take you to the Wireless System’ Home Page.

Select Access Control button, you’ll be asked for the password. You should be on the Access Control page were you can simply type in the desired Static IP address, and click Save.

For more details about the "Access Control" page refer to Section 4.3.10.

ACCESS CONTROL

Address http://192.168.1.200

ACCESS CONTROL

Login Password 12345678

Admin Password 00000000

Host Name wis21d9

MAC Address 00:03:03:00:21:D9

IP Address 192.168.1.200

Gateway Address 0.0.0.0

Subnet Mask 255.255.255.0

Save Reset

Network Reset

Main Menu

Figure 4.4 Access Control

For the IP address to take effect, the Meter needs to be turned OFF and ON using the "Network Reset" button. Pressing the physical button marked "RESET" on the Meter does the same thing.

You can now connect the Meter to an Ethernet hub using a straight through cable, power it up, and follow the ping routine mentioned in the previous section.

24

Image 30
Contents User’sGuide Page Table of Contents List of Figures 19a List of Tables Safety Considerations Part IntroductionDescription Customer ServiceBefore You Begin Inspecting Your ShipmentDescription Rockwell Automation, and National Instruments, among others Physical Characteristics and Mounting 2.1.1 Front Panel Front Panel EnunciatorsRear Panel Connector Rear PanelNetwork Dimensions Mounting DimensionsAssembly and Mounting 2.1.4.1 Panel Mounting Instruction Panel MountingAntenna Mounting Instruction Antenna MountingDisassembly Instruction Accessing the Main Board AssemblyElectrical Installation Power Connections Use copper conductors only for power connectionsOutputs Wiring Hookup Wiring OutputsOutputs Wiring Hookup Pulse and AnalogTypical Applications Fast BlowJumper Settings for Display Color Setup 10 Location of S1 JumperDip Switches PositionNetwork Communication Interfaces 1 10Base-T RJ-45 Pinout Pin Name DescriptionEthernet MAC Address Network Protocols .1 Label DetailDhcp 4 Position DIP Switch DNSDefault IP Address IP AddressChanging TCP/IP Properties on Your Computer SectionTesting the Connection Pinging the Meter from MS-DOS PromptAssigning an IP Address using iConnect IConnect SoftwareWireless Sensor Home Setting a New IP Address over the Network Access ControlMeter’s Configurations and Operations Wireless System Home Page MenuLogin Administrator Power Up MeterGet Readings from the End Device LabGet Readings from the End Device ID End Device ID/address Java Runtime Environment Setup Java 1.5.x.x. Screen ShotsJava Runtime Environment 1.4 Setup Instructions 10 Java 1.4.2.x Screen ShotDiagnostics Accessing Meter units within your internal networkAccessing Meter units using the internet Accessing Meter units over Peer-to-Peer networkJava Policy 11 Java PolicyDjava.security.policy=C\0JAVAPOLICY\javapolicy.txt 12 Java PolicyChart 13 ChartChart Controller Setup 14 Controller SetupMonitor SetupTransmission Power MiscellaneousSetup InputSetpoints & On/Off Control Setpoints & On/Off Control Alarms 1 Setup Setup Analog Output RetransmissionDisplay 19a Display Menu19b Display Menu if Analog Output Option Display Color Examples ExampleAmber Passcode ID 20 ID CodeGeneral Network SetupRemote Access Tunneling Terminal ServerRemote Access GeneralTerminal Server End Device Setup 22 End Device SetupEnd Device Parameters Sensor1 Sensor2Sensor T75F T74FUpdate CancelDisplay Access Control Telnet Setup List of Ascii / Telnet Commands 01 indicates End Device #1Command Description Response HTTPget using Port HTTPget ProgramConnector/Transmitter Types HTTPget and ARP to Setup Device IP Address27 ARP Commands and Responses ARP ProtocolILog Software 28 iLog Software Logging Data for End Device #2, 6Networked Product ILog File Alternate Wireless DevicesILog Software ILog Excel Applications Networked Product Auto FullInstallation Mail Notifier SoftwareEmail Address Setup Email SetupDevice Setting and Configuration Mail Notifier CommandsAlarm Editor Environment / Operating Conditions General Deployment GuidelinesOperation in Buildings With Line-of-Sight Distance feetMaterial Type Without Line-of-SightCasing and Closure Around the Antenna See .1.4.2 and FigurePart Specifications General Safety & Regulatory Compliance Factory Preset Values InputFactory Preset Values Setpoints & On/Off Control AlarmPasscode ID Access Control Factory Preset Values Analog Output RetransmissionRemote Access Tunneling MiscFactory Preset Values End Device Setup End Device # 1Appendix Aglossary Appendix BIP Address Address Class Mask Binary Value Mask Decimal Value Ascii Dec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Maximum Power Levels and Antenna Gains WARRANTY/DISCLAIMER Shop on line at omega.com PH/CONDUCTIVITY