8254B COUNTER 1 DATA - USER COUNTER #5
BADR3 + 9
READ/WRITE
7 | 6 | 5 | 4 | 2 | 3 | 1 | 0 |
|
|
|
|
|
|
|
|
D7 | D6 | D5 | D4 | D3 | D2 | D1 | D0 |
|
|
|
|
|
|
|
|
The clock, gate and output lines of Counter 1 are available to the user at the
8254B COUNTER 2 DATA - USER COUNTER #6
BADR3 + Ah
READ/WRITE
7 | 6 | 5 | 4 | 2 | 3 | 1 | 0 |
|
|
|
|
|
|
|
|
D7 | D6 | D5 | D4 | D3 | D2 | D1 | D0 |
|
|
|
|
|
|
|
|
The clock, gate and output lines of Counter 2 are available to the user at the
8254B CONTROL REGISTER
BADR3 + Bh
WRITE ONLY
7 | 6 | 5 | 4 | 2 | 3 | 1 | 0 |
|
|
|
|
|
|
|
|
D7 | D6 | D5 | D4 | D3 | D2 | D1 | D0 |
|
|
|
|
|
|
|
|
The control register is used to set the operating Modes of 8254B Counters 0,1 & 2. A counter is configured by writing the correct Mode information to the Control Register, then the proper count data must be written to the specific Counter Register.
The Counters on the 8254 are
Register is
32