5.The next time you dial a HyperTerminal connection, it will select your new modem and ask you to confirm the selection.

Step 3: Install and Configure Your Software

Your Multi-Tech modem is controlled by communication software installed on your computer. If you wish to use software that is already installed, you should reconfig- ure it for your new modem; otherwise, install the Trio data and fax communications software provided with the modem.

1.Turn on your computer and run your communications software.

2.Find the dialog box or menu that lets you specify your modem. (In Windows Terminal select Settings Modem Commands; in HyperTerminal select File Properties Phone Number; and in Trio select View Datacomm Communi- cations Setup Modem Select from List.

3.Choose your modem from the software’s modem list. If it isn’t listed, choose a generic modem and modify the settings as necessary.

4.Change the modem initialization string, if necessary. The factory default config- uration works well for most purposes. To load the factory default configuration, use AT&F. To load a custom configuration that was saved using the &W com- mand, use ATZ. Note that the Z command must be in a command string by it- self. For a Macintosh, the initialization string should include the &D0 command. If you do not want the modem to always answer the phone, add S0=0 to the string. To use Caller ID with the modem, add S0=2 to the string (Caller ID infor- mation is sent between the first and second rings, so the phone must ring at least twice befor the modem picks up the line). Depending on the software, you might have to end the string with a carriage return character (^M).

Note: To change the modem’s default configuration, type new commands in the communication program’s terminal window, adding the &W command to store them in the modem’s nonvolatile memory. For instance, to create a default configuration for a Macintosh computer that turns off autoanswer, type AT&F&D0S0=0&W. The new configuration loads automatically whenever the modem is turned on or receives the ATZ command.

5.Select the port the modem is connected to (normally COM1 or COM2).

6.Select your serial port speed. This can be labeled “maximum speed,” “DTE bps,” or “baud rate.” Ideally, if you use data compression, you should set your serial port baud rate to four times the modem’s maximum transmission speed or faster; however, few files can be compressed enough to require speeds that high, and not all serial ports can handle speeds that high. Set the serial port baud rate to 115,200 bps if your computer has a high speed serial port with a 16550AFN UART or equivalent and Windows 95 or NT 4.0, or set it to 57,600 bps if it has Windows 3.1x. If you have an older computer with a 14550 UART, set it to

19,200 bps. Older Macintosh computers can use a serial port baud rate of 57,600 bps; newer ones can use a serial port baud rate of 115,200 bps or 230,400 bps.

10

Image 18
Contents Model MT5600BA Model MT5600BL Record of Revisions FCC Part Quick Start Using the Front PanelIntroduction MultiModemII User GuideSolving Problems AT Commands, S-Registers & Result CodesRemote Configuration Callback SecurityAppendix C Loopback Tests Appendix D Warranty, Service, and Technical SupportAppendix a Regulatory Compliance Appendix E Upgrading the ModemContents Viii Introduction Features IntroductionProduct Description Introduction DataWhat Is in Your Modem Package? Related ManualsQuick Start We supply Safety WarningsWhat You Will Need You supplyDialup Connection Connect the Modem to Your SystemRS232 Connection Quick StartPower Connection Two-Wire Leased Line ConnectionFour-Wire Leased Line Connection Power-On TestInstall the Modem in Windows Adding the Modem to WindowsRemoving Your Old Modem from Windows Install and Configure Your Software Call the Multi-Tech BBS Trio DataCommWindows HyperTerminal Windows Terminal Send a Fax Trio FaxMicrosoft Fax Select Start Programs Accessories Fax Compose new fax ReferencesMultiModemII User Guide Using the Front Panel Modem Configuration LED IndicatorsOption Selection Using the Front PanelLiquid Crystal Display LCD Menu StructureMultiModemII User Guide Menu Overview Using the Front Panel Status Trunk MultiModemII User Guide Basic Options Trunk Using the Front Panel Advanced Options Trunk MultiModemII User Guide Remote Configuration Options Trunk Diagnostic Options TrunkUsing the Front Panel Phone Number Memory Options Trunk Caller ID Options TrunkMenu Options StatusUsing the Front Panel Basic Options Advanced Options ImplementedRemote Configuration Options MultiModemII User Guide Diagnostic Options Phone Number Memory OptionsCaller ID Options AT Commands Registers Result Codes Introduction AT Commands AT Commands, S-Registers, and Result CodesHook Control Echo Command Mode CharactersDS= y Dial Stored Telephone Number Information RequestReturn Online to Data Mode Monitor Speaker VolumeMonitor Speaker Mode Result Codes Enable/DisableRead Register Value Select RegisterSet Register Value Tone DialingLong Space Disconnect Modem ResetResult Code Selection Data Carrier Detect DCD ControlData Terminal Ready DTR Control Error Correction ModesLoad Factory Settings Modem-Initiated Flow ControlCommunications Mode 22bis Guard Tone ControlFlow Control Selection Clear to Send CTS Control Sync/Async ModeTest Commands Data Set Ready DSR ControlDisplay Last Connection Statistics Display Current ConfigurationStore Current Configuration Synchronous Clock SourceZy =x Store Telephone Number Select Profile for Hard ResetLine Signal Level Data Compression Control\An Maximum MNP Block Size Line Signal QualityPCM Code Selection \Bn Transmit Break\Nn Error Correction Mode Selection \Vn Single Line Connect Message+MS= Modulation Selection Reserved,maxTXrateCRMNP Extended Services Command #CBPy=x Store Callback Password Command -SDR=nDistinctive Ring ControlCommand #CBNy=x Store Callback Number Flash Memory DownloadCommand $SBn Serial Port Baud Rate Command #CID= n Caller IDCallback Enable/Disable Escape SequenceRegister Unit Range Default Description RegistersS32 S36 S46 Result Codes Terse Verbose DescriptionProtocol ALT +FCERROR MultiModemII User Guide Remote Configuration Basic Procedure SetupChanging the Remote Configuration Password Remote Configuration Changing the Remote Escape CharacterMultiModemII User Guide Callback Security Setup Procedures Turning Callback Security On and OffAssigning Callback Passwords Callback SecurityAssigning Callback Phone Numbers Calling Procedure Callback Security CommandsCommand #CBN y= x Store Callback Number Command #CBPy=x Store Callback Password Callback Assignments MultiModemII User Guide Leased Line Operation Two-Wire Setup Four-Wire Setup Leased Line OperationDial Backup and Leased Line Restoral Dial Backup and Leased Line Restoral SetupLeased Line Operation MultiModemII User Guide Solving Problems None of the Indicators Light Modem Does Not Respond to Commands Solving ProblemsModem Dials But Cannot Connect Modem4Disconnects While Online Modem4Cannot Connect When Answering File Transfer4Is Slower Than It Should BeData Is Being Lost There Are Garbage4 Characters on the MonitorModem4Doesn’t Work with Caller ID Fax and Data4Software Can’t Run at the Same Time Appendixes Appendix a Regulatory Compliance FCC Part 68 TelecomFax Branding Statement Regulatory ComplianceCanadian Limitations Notice International Modem RestrictionsCommission Decision CTR21 EMC, Safety, and Terminal Directive Compliance New Zealand Telecom Warning NoticeAppendix B Technical Specifications Technical Specifications Receiver Sensitivity Test procedure Local Analog Loopback Test V.54 LoopLoopback Tests Remote Digital Loopback Test V.54 Loop Figure C-2. Remote digital loopback testLocal Digital Loopback Test V.54 Loop Figure C-3. Local digital loopback testBack-to-Back Test Figure C-5. Back-to-back test connections Limited Warranty ServiceTechnical Support Online Warranty RegistrationWarranty, Service, and Technical Support Multi-Tech BBSAbout the Internet Ordering Modem Accessories SupplyNet Online Ordering InstructionsUpgrade Overview Identify the Modem FirmwareMulti-Tech BBS Identify the Current Firmware VersionMulti-Tech Web Site Upgrading the ModemDownload the Upgrade File Extract the Upgrade FilesSet the Modem to the Factory Defaults Upgrade the Modem’s Firmware Restore Your ParametersAppendix F Cable Pinouts RS-232 PinoutsLeased Line Pinouts Cable PinoutsAppendix G Ascii Character Map Ctrl Code Hex DecIndex 108 Index 110