behind a corporate phone system (PBX) with an internal dial tone that sounds different from the normal dial tone. In that case, the modem might not recognize the dial tone and might treat it as an error. Check your PBX manual to see if you can change the internal dial tone; if you can’t, change your modem’s initializa- tion string to replace X4 with X3, which will cause the modem to ignore dial tones (note, however, that X3 is not allowed in some countries, such as France

4and Spain).

If the modem reports BUSY, the other number might be busy, in which case you should try again later, or it might indicate that you have failed to add a 9, prefix to the phone number if you must dial 9 for an outside line.

If you must dial 9 to get an outside line, the easiest way to dial it automatically is to include it in the modem’s dial prefix, e.g., ATDT9,. Note the comma, which inserts a pause before the number is dialed. By inserting 9, into the dial prefix, you do not have to include it in each directory entry.

To change the dial prefix in Windows 95 HyperTerminal, select Connect from the Call menu, click Dialing Properties, and type 9 in the local and long distance boxes in How I dial from this location.

If the modem reports NO ANSWER, the other system has failed to go off-hook, or

4you might have dialed a wrong number. Check the number.

If the modem reports NO CARRIER, the phone was answered at the other end, but no connection was made. You might have dialed a wrong number, and a per- son answered instead of a computer, or you might have dialed the correct number but the other computer or software was turned off or faulty. Check the number and try again, or try calling another system to make sure your modem is working. Also, try calling the number on your telephone. If you hear harsh sounds, then another modem is answering the call, and the modems might be having problems negotiating because of modem incompatibilities or line noise. Try connecting at a lower speed.

The Modem4Disconnects While Online

If you have Call Waiting on the same phone line as your modem, it can interrupt your connection when someone tries to call you. If you have Call Waiting, dis- able it before each call. In most telephone areas in North America, you can disable Call Waiting by preceding the telephone number with *70 (check with your local telephone company).

You can automatically disable Call Waiting by including the disabling code in the modem’s dial prefix (e.g., ATDT*70,—note the comma, which inserts a pause before the number is dialed). To change the dial prefix in Windows Terminal, se- lect Settings Modem Commands. To change it in HyperTerminal, select Connect from the Call menu, click Dialing Properties, check This location has

4Call Waiting, and select the correct code for your phone service.

If you have extension phones on the same line as your modem, you or someone else can interrupt the connection by picking up another phone. If this is a fre- quent problem, disconnect the extension phones before using the modem, or install another phone line especially for the modem.

79

Image 87
Contents Model MT5600BA Model MT5600BL Record of Revisions FCC Part MultiModemII User Guide Using the Front PanelIntroduction Quick StartCallback Security AT Commands, S-Registers & Result CodesRemote Configuration Solving ProblemsAppendix E Upgrading the Modem Appendix D Warranty, Service, and Technical SupportAppendix a Regulatory Compliance Appendix C Loopback TestsContents Viii Introduction Features IntroductionProduct Description Data IntroductionRelated Manuals What Is in Your Modem Package?Quick Start You supply Safety WarningsWhat You Will Need We supplyQuick Start Connect the Modem to Your SystemRS232 Connection Dialup ConnectionPower-On Test Two-Wire Leased Line ConnectionFour-Wire Leased Line Connection Power ConnectionInstall the Modem in Windows Adding the Modem to WindowsRemoving Your Old Modem from Windows Install and Configure Your Software Trio DataComm Call the Multi-Tech BBSWindows HyperTerminal Windows Terminal Send a Fax Trio FaxMicrosoft Fax References Select Start Programs Accessories Fax Compose new faxMultiModemII User Guide Using the Front Panel LED Indicators Modem ConfigurationMenu Structure Using the Front PanelLiquid Crystal Display LCD Option SelectionMultiModemII User Guide Menu Overview Using the Front Panel Status Trunk MultiModemII User Guide Basic Options Trunk Using the Front Panel Advanced Options Trunk Diagnostic Options Trunk MultiModemII User Guide Remote Configuration Options TrunkCaller ID Options Trunk Using the Front Panel Phone Number Memory Options TrunkStatus Menu OptionsUsing the Front Panel Basic Options Implemented Advanced OptionsRemote Configuration Options MultiModemII User Guide Diagnostic Options Phone Number Memory OptionsCaller ID Options AT Commands Registers Result Codes Introduction AT Commands, S-Registers, and Result Codes AT CommandsInformation Request Echo Command Mode CharactersDS= y Dial Stored Telephone Number Hook ControlResult Codes Enable/Disable Monitor Speaker VolumeMonitor Speaker Mode Return Online to Data ModeTone Dialing Select RegisterSet Register Value Read Register ValueData Carrier Detect DCD Control Modem ResetResult Code Selection Long Space DisconnectModem-Initiated Flow Control Error Correction ModesLoad Factory Settings Data Terminal Ready DTR ControlCommunications Mode 22bis Guard Tone ControlFlow Control Selection Data Set Ready DSR Control Sync/Async ModeTest Commands Clear to Send CTS ControlSynchronous Clock Source Display Current ConfigurationStore Current Configuration Display Last Connection StatisticsData Compression Control Select Profile for Hard ResetLine Signal Level Zy =x Store Telephone Number\Bn Transmit Break Line Signal QualityPCM Code Selection \An Maximum MNP Block Size\Vn Single Line Connect Message \Nn Error Correction Mode SelectionReserved,maxTXrateCR +MS= Modulation SelectionMNP Extended Services Flash Memory Download Command -SDR=nDistinctive Ring ControlCommand #CBNy=x Store Callback Number Command #CBPy=x Store Callback PasswordEscape Sequence Command #CID= n Caller IDCallback Enable/Disable Command $SBn Serial Port Baud RateRegisters Register Unit Range Default DescriptionS32 S36 S46 Terse Verbose Description Result CodesProtocol ALT +FCERROR MultiModemII User Guide Remote Configuration Basic Procedure SetupChanging the Remote Configuration Password Changing the Remote Escape Character Remote ConfigurationMultiModemII User Guide Callback Security Turning Callback Security On and Off Setup ProceduresCallback Security Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Callback Security CommandsCommand #CBN y= x Store Callback Number Command #CBPy=x Store Callback Password Callback Assignments MultiModemII User Guide Leased Line Operation Two-Wire Setup Leased Line Operation Four-Wire SetupDial Backup and Leased Line Restoral Setup Dial Backup and Leased Line RestoralLeased Line Operation MultiModemII User Guide Solving Problems None of the Indicators Light Solving Problems Modem Does Not Respond to CommandsModem Dials But Cannot Connect Modem4Disconnects While Online File Transfer4Is Slower Than It Should Be Modem4Cannot Connect When AnsweringData Is Being Lost There Are Garbage4 Characters on the MonitorModem4Doesn’t Work with Caller ID Fax and Data4Software Can’t Run at the Same Time Appendixes FCC Part 68 Telecom Appendix a Regulatory ComplianceRegulatory Compliance Fax Branding StatementCanadian Limitations Notice International Modem RestrictionsCommission Decision CTR21 New Zealand Telecom Warning Notice EMC, Safety, and Terminal Directive ComplianceAppendix B Technical Specifications Technical Specifications Receiver Sensitivity Test procedure Local Analog Loopback Test V.54 LoopLoopback Tests Figure C-2. Remote digital loopback test Remote Digital Loopback Test V.54 LoopFigure C-3. Local digital loopback test Local Digital Loopback Test V.54 LoopBack-to-Back Test Figure C-5. Back-to-back test connections Service Limited WarrantyMulti-Tech BBS Online Warranty RegistrationWarranty, Service, and Technical Support Technical SupportAbout the Internet SupplyNet Online Ordering Instructions Ordering Modem AccessoriesIdentify the Modem Firmware Upgrade OverviewUpgrading the Modem Identify the Current Firmware VersionMulti-Tech Web Site Multi-Tech BBSDownload the Upgrade File Extract the Upgrade FilesSet the Modem to the Factory Defaults Restore Your Parameters Upgrade the Modem’s FirmwareRS-232 Pinouts Appendix F Cable PinoutsCable Pinouts Leased Line PinoutsCtrl Code Hex Dec Appendix G Ascii Character MapIndex 108 Index 110