Multi-Tech Systems MT5600BL, MT5600BA manual Windows Terminal

Page 21

2 Quick Start

13.Press ENTER twice more.

14.Type Z and press ENTER to select the Zmodem transfer protocol.

15.The download begins automatically. As the file is copied to the HyperTerminal folder, a dialog box reports on the progress of the download. If the download fails, your baud rate may be set too high. Log off, set the COM port baud rate lower, and call again.

16.To log off the BBS, press ENTER, type G for “good-bye,” and press ENTER twice more.

17.In the HyperTerminal window, click File, and then click Save to save the HyperTerminal connection description.

Windows Terminal

1.Open the Accessories program group and double-click on the Terminal icon.

2.Select the Settings menu and make the following changes:

Phone Number: Type 1-800-392-2432if you are in North America, or type an overseas access code and 612-785-3702if you are outside North America.

Communications: Select the COM port the modem is connected to and change the

following: Baud rate to 19200; Flow control to Hardware; and Carrier Detect to checked.

Modem Commands: Select MultiTech. If you must dial 9 to get an outside line, type ATDT9, in the Dial prefix box (include the comma).

3.Click File, then click Save, and save as multibbs.trm.

4.Click Phone, then click Dial to dial the BBS. You will know you have reached a modem by the harsh sounds of the modem handshake.

5.When the BBS welcome screen appears in the Terminal window, type your first name, last name, and password following the prompts. If you are a first-time caller, the BBS asks if your name is spelled correctly. If you answer Y, a ques- tionnaire appears. You must complete the questionnaire to use the BBS on your first call.

6.Press ENTER until the Main Menu appears. From the Main Menu you have access to two areas: the File Menu and News. For help with menu commands, type ?.

7.In the Main Menu, type F and press ENTER to access the File Menu, then type D and press ENTER to download.

8.At the file name prompt, if you have Microsoft Word 6.0 or later, type register.doc and press ENTER. If you do not have Microsoft Word, type register.txt and press

ENTER.

9.Press ENTER twice more.

10.Type X and press ENTER to select the Xmodem transfer protocol.

11.To begin the download in Terminal, click Transfers, then click Receive binary file. Next, select the destination directory, type the file name (register.doc or register.txt), and click OK. If the download fails, your baud rate may be set too high. Log off, set the COM port baud rate lower, and call again.

13

Image 21
Contents Model MT5600BA Model MT5600BL Record of Revisions FCC Part Introduction Using the Front PanelQuick Start MultiModemII User GuideRemote Configuration AT Commands, S-Registers & Result CodesSolving Problems Callback SecurityAppendix a Regulatory Compliance Appendix D Warranty, Service, and Technical SupportAppendix C Loopback Tests Appendix E Upgrading the ModemContents Viii Introduction Features IntroductionProduct Description Data IntroductionRelated Manuals What Is in Your Modem Package?Quick Start What You Will Need Safety WarningsWe supply You supplyRS232 Connection Connect the Modem to Your SystemDialup Connection Quick StartFour-Wire Leased Line Connection Two-Wire Leased Line ConnectionPower Connection Power-On TestInstall the Modem in Windows Adding the Modem to WindowsRemoving Your Old Modem from Windows Install and Configure Your Software Trio DataComm Call the Multi-Tech BBSWindows HyperTerminal Windows Terminal Send a Fax Trio FaxMicrosoft Fax References Select Start Programs Accessories Fax Compose new faxMultiModemII User Guide Using the Front Panel LED Indicators Modem ConfigurationLiquid Crystal Display LCD Using the Front PanelOption Selection Menu StructureMultiModemII User Guide Menu Overview Using the Front Panel Status Trunk MultiModemII User Guide Basic Options Trunk Using the Front Panel Advanced Options Trunk Diagnostic Options Trunk MultiModemII User Guide Remote Configuration Options TrunkCaller ID Options Trunk Using the Front Panel Phone Number Memory Options TrunkStatus Menu OptionsUsing the Front Panel Basic Options Implemented Advanced OptionsRemote Configuration Options MultiModemII User Guide Diagnostic Options Phone Number Memory OptionsCaller ID Options AT Commands Registers Result Codes Introduction AT Commands, S-Registers, and Result Codes AT CommandsDS= y Dial Stored Telephone Number Echo Command Mode CharactersHook Control Information RequestMonitor Speaker Mode Monitor Speaker VolumeReturn Online to Data Mode Result Codes Enable/DisableSet Register Value Select RegisterRead Register Value Tone DialingResult Code Selection Modem ResetLong Space Disconnect Data Carrier Detect DCD ControlLoad Factory Settings Error Correction ModesData Terminal Ready DTR Control Modem-Initiated Flow ControlCommunications Mode 22bis Guard Tone ControlFlow Control Selection Test Commands Sync/Async ModeClear to Send CTS Control Data Set Ready DSR ControlStore Current Configuration Display Current ConfigurationDisplay Last Connection Statistics Synchronous Clock SourceLine Signal Level Select Profile for Hard ResetZy =x Store Telephone Number Data Compression ControlPCM Code Selection Line Signal Quality\An Maximum MNP Block Size \Bn Transmit Break\Vn Single Line Connect Message \Nn Error Correction Mode SelectionReserved,maxTXrateCR +MS= Modulation SelectionMNP Extended Services Command #CBNy=x Store Callback Number Command -SDR=nDistinctive Ring ControlCommand #CBPy=x Store Callback Password Flash Memory DownloadCallback Enable/Disable Command #CID= n Caller IDCommand $SBn Serial Port Baud Rate Escape SequenceRegisters Register Unit Range Default DescriptionS32 S36 S46 Terse Verbose Description Result CodesProtocol ALT +FCERROR MultiModemII User Guide Remote Configuration Basic Procedure SetupChanging the Remote Configuration Password Changing the Remote Escape Character Remote ConfigurationMultiModemII User Guide Callback Security Turning Callback Security On and Off Setup ProceduresCallback Security Assigning Callback PasswordsAssigning Callback Phone Numbers Calling Procedure Callback Security CommandsCommand #CBN y= x Store Callback Number Command #CBPy=x Store Callback Password Callback Assignments MultiModemII User Guide Leased Line Operation Two-Wire Setup Leased Line Operation Four-Wire SetupDial Backup and Leased Line Restoral Setup Dial Backup and Leased Line RestoralLeased Line Operation MultiModemII User Guide Solving Problems None of the Indicators Light Solving Problems Modem Does Not Respond to CommandsModem Dials But Cannot Connect Modem4Disconnects While Online File Transfer4Is Slower Than It Should Be Modem4Cannot Connect When AnsweringData Is Being Lost There Are Garbage4 Characters on the MonitorModem4Doesn’t Work with Caller ID Fax and Data4Software Can’t Run at the Same Time Appendixes FCC Part 68 Telecom Appendix a Regulatory ComplianceRegulatory Compliance Fax Branding StatementCanadian Limitations Notice International Modem RestrictionsCommission Decision CTR21 New Zealand Telecom Warning Notice EMC, Safety, and Terminal Directive ComplianceAppendix B Technical Specifications Technical Specifications Receiver Sensitivity Test procedure Local Analog Loopback Test V.54 LoopLoopback Tests Figure C-2. Remote digital loopback test Remote Digital Loopback Test V.54 LoopFigure C-3. Local digital loopback test Local Digital Loopback Test V.54 LoopBack-to-Back Test Figure C-5. Back-to-back test connections Service Limited WarrantyWarranty, Service, and Technical Support Online Warranty RegistrationTechnical Support Multi-Tech BBSAbout the Internet SupplyNet Online Ordering Instructions Ordering Modem AccessoriesIdentify the Modem Firmware Upgrade OverviewMulti-Tech Web Site Identify the Current Firmware VersionMulti-Tech BBS Upgrading the ModemDownload the Upgrade File Extract the Upgrade FilesSet the Modem to the Factory Defaults Restore Your Parameters Upgrade the Modem’s FirmwareRS-232 Pinouts Appendix F Cable PinoutsCable Pinouts Leased Line PinoutsCtrl Code Hex Dec Appendix G Ascii Character MapIndex 108 Index 110
Related manuals
Manual 12 pages 16.1 Kb