Magnum 6K32 & 6K32T Managed Switch | Installation and User Guide (12/05) |
3.2.5Connecting Twisted Pair
connected via copper media with the following minimum specifications;
Media | IEEE Standard | Connector |
Twisted Pair |
|
NOTE : It is recommended that high quality
The following procedure describes how to connect a
1.
2.Connect the other end of the cable to the corresponding device
3.Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established
3.2.6Power Budget Calculations for Magnum 6K32T PM’s with Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = PT(min) - PR(min)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125∝m (M.m) is 2.8 dB/km, and the “Cable Loss” for 100/140
and the “Cable Loss” for 9/125
and the “Cable Loss” for 9/125
(LXSC40)
and the “Cable Loss” for 9/125
The following data has been collected from component manufacturer’s (Agilent’s and Lucent’) web sites and catalogs to provide guidance to network designers and installers.
www . GarrettCom . com
25