GarrettCom Magnum 6K32T user manual C5.0 Installation

Page 66

Magnum 6K32 & 6K32T Managed Switch

Installation and User Guide (12/05)

reversed while the Switch is operating from the other source.

e)The Switch will not receive power (and will not work) when both inputs are simultaneously absent or are both incorrectly connected.

C5.0 INSTALLATION

This section describes the proper connection of the -48VDC, 24VDC and 125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )

The -48VDC terminal block on the Magnum 6K32T Switch, as shown in Fig C5.0 is

located on the right rear of the unit and

 

 

 

is equipped with five (5) screw-down

A+ A-

B- B+

 

lead posts. If it is the reverse model it

 

 

 

is located on the left rear. The primary

 

 

 

terminals are identified as positive

 

 

 

(A+), negative (A-), and the secondary

 

36-70VDC

 

power terminals as negative (B-),

36-70VDC

GND

 

 

 

positive(B+). The chassis “earth” or ground (GND) is a threaded post with a #6 nut. The Dual Source terminal block for the 24VDC and 125VDC are similar.

Figure C5.0: -48VDC Dual-Source, wiring connections to the External Terminal Block on a Magnum 48VDC with Dual-Source option

Note: The GND should be hooked up first. The6K32T unit has a floating ground, so the user may elect to Ground either + or = terminal to suit the customer’s use.

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

The connection procedure is straightforward. Simply connect the DC leads to the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened.

The 24VDC and 125VDC terminal block on Magnum 6K32T & 6K32’s is similar to that described in the –48VDC information above.

www . GarrettCom . com

60

Image 66
Contents Managed Switch Trademarks Contacting GarrettCom, Inc Canadian EmissionTable of Contents IntroductionMagnum 6K32T Managed Switch Port Modules Personal Switches, 10/100Mb Personal Hubs, 10Mb seriesTechnical Specifications Power Supply Internal Fiber connector types supportedManagement Console connector LEDs Per PortRelay Alarm Contact Optional Per-port MDI or Mdix on RJ-45Agency Approvals Magnum 6K32T Port Modules Configuration OptionsOrdering Information Gigabit Transceiver optionsWww . GarrettCom . com Introduction Inspecting the Package and Product Product Description Magnum 6K32T Managed Switch 1a Magnum 6K32T Chassis 1b New Magnum 6K32T Chassis Mode for best fiber distance Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber100Mb fiber eight Port modules for the Magnum Eight-Port Copper Module, 6K8-RJ45 Four-Port 10 Mb mm Fiber ST Modules @RJ-45 + 2@ 100MbST or SC Gigabit 1000Mbps port modules Packet Prioritization, 802.1p QOS Frame Buffering and Flow ControlManaged Network Software MNS-6K for Magnum 6K32T MIBs for Snmp visitFeatures and Benefits „ Managed switching for high performance Ethernet LANs„ Features Fiber-Built-In Example 1 Magnum 6K32T Switch for a Vlan application ApplicationsData Example 3 Redundant Application Www . GarrettCom . com Www . GarrettCom . com Installation Locating Magnum 6K32T SwitchesIeee Standard Media Type Max. Distance Port Module Fiber Connecting Ethernet MediaConnecting Fiber Optic ST-type, twist-lock CopperConnecting Fiber Optic SC-type, Snap-In Connecting Single-Mode Fiber OpticMedia Ieee Standard Twisted Pair CAT-5e 1000BASE-T F10ST Table-Top or Shelf Mounting Rack-mounting for 19 Retma racks, Magnum 6K32T’sMagnum 6K32T unit. These Rack-mounting, Reverse version of the Magnum 6K32T’s 1 Dual Side-Mountings for Magnum 6K32T unitsPowering the Magnum 6K32T Managed Switch 6K32T Port Module 6KPM Installation Preparation for Installing and Removing 6KPMsRemove Chassis Cover Installing 6KPM Cards in the Magnum 6K32T 1d Top View 6KPM retaining screws hold Face PlateWww . GarrettCom . com 2g Top View 6KPM Module installed inside a 6K32T Switch Removing 6KPM Cards Firmly. .5.3a Top View 6 retaining screws shown by arrowsRemove 6KPM Card Connecting the Console Terminal to Magnum 6K32T ManagementConsole DB-9 Port Rear View of Magnum 6K32TDB-9 Console port connector Pin Signal DescriptionSwitching Functionality 1 RS-232 DB-9 Console Com port Serial port pin assignmentsStatus LEDs PWRACT Auto-Cross MDIXAuto-negotiation, for 10/100Mbps RJ-45 ports Www . GarrettCom . com Magnum 6K32T Managed Switch Port Modules Flow-control, Ieee 802.3x standard6KPM Module Description 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Magnum 6KP4 Connectors and configuredAs 10Mb Half-duplex by Default for 10Mb fiber Flstfx is a combo fiberTransceivers all in one module. This Mode 100Mbps fiber opticMode SC-type connectors. It Activity ACT, Link LK,Www . GarrettCom . com Activity FULL/HALF 6KP8-MTRJPort@ 100Mbps Multi-Mode Fiber port Link7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector Small 9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port Small size of LC connectors Give an advantage of placing morePorts on one module. The 6KP8-45 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector@ 1000Mb Fiber SC + 2@ 100Mb SC @ 1000Mb Fiber SC12 6KM-BLNK Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationAppendix B Internal DC Power Supply Options B1.0 Specifications for Magnum 6K32T SWITCHES, DC PowerPower Supply Internal -48VDC Option B3.0 Applications for DC Powered Switches B4.0 InstallationB5.0 Operation Appendix C Internal DC Dual-Source Power OptionB7.0 Troubleshooting B6.0 Ordering InformationC4.0 Features and Benefits of the DUAL-SOURCE Design C5.0 Installation Example Magnum 6K32T & 6K32-48VDC C5.1 UL RequirementsC6.0 Ordering Information C7.0 Operation