These brackets are rack-mounted in a frame typically accessed in operation from both sides.

The bracket mounting holes in the sides of the Magnum 6K32T permits it to be mounted in various ways. The same holes fit all three types (19”, ETSI, and 23”) of brackets. The mounting for the 23” is illustrated in Figure 3.3.1 below. The brackets may be attached flush with the front, or attached in the center for a set-back mounting which may reduce cabling torque.

The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a package, along with the necessary screws for attaching the brackets to the sides of the Magnum Switch unit. They must be ordered as separate line items.

3.3.2 Rack-mounting, Reverse version of the Magnum 6K32T’s

(Not available as of October 2005) The optional Reverse Magnum 6K32T Model has all of the cabling (Ethernet cabling, power cabling and console port cabling) connectors in the rear, and the status LEDs in the front. The status LEDs that are co- incident with the ports are still present there, and a second or dual set of LEDs are used for status visibility in the front of the unit, showing the same data.

There are three options of brackets available to mount in the standard 19” frame, 23” frame, or ETSI (21”) frame. The 19” brackets are included with each unit, the other two may be purchased as separate options.

With each bracket type, there are three different mounting options as shown in Fig. 3.3.2. The case of the Magnum 6K32T has mounting holes prepared for each of the mounting arrangements. Users may choose the mounting arrangement most suitable for their installation.

D

D C

 

C B

 

B A

 

Standard Flush

 

 

 

 

 

 

 

 

 

Mount Bracket

 

 

 

 

 

 

 

 

 

Mid-Range Mount

 

 

D

D C

C B

B

A

 

A

or

 

 

 

 

 

 

 

 

 

 

Fig

3.3.2

 

 

 

 

 

 

 

Rear Mount

Reverse

 

 

 

 

 

 

 

Magnum

D

D C

C B

B A

 

 

A

 

 

 

 

6K32T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units, rack-

 

 

 

 

 

 

 

 

mounted in

 

 

 

 

 

 

 

 

a frame

www . GarrettCom . com

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

Image 34
Contents Managed Switch Trademarks Contacting GarrettCom, Inc Canadian EmissionTable of Contents IntroductionMagnum 6K32T Managed Switch Port Modules Personal Switches, 10/100Mb Personal Hubs, 10Mb seriesTechnical Specifications Power Supply Internal Fiber connector types supportedManagement Console connector LEDs Per PortPer-port MDI or Mdix on RJ-45 Relay Alarm Contact OptionalAgency Approvals Magnum 6K32T Port Modules Configuration OptionsOrdering Information Gigabit Transceiver optionsWww . GarrettCom . com Introduction Inspecting the Package and Product Product Description Magnum 6K32T Managed Switch 1a Magnum 6K32T Chassis 1b New Magnum 6K32T Chassis Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber Mode for best fiber distance100Mb fiber eight Port modules for the Magnum Eight-Port Copper Module, 6K8-RJ45 @RJ-45 + 2@ 100Mb Four-Port 10 Mb mm Fiber ST ModulesST or SC Gigabit 1000Mbps port modules Packet Prioritization, 802.1p QOS Frame Buffering and Flow ControlManaged Network Software MNS-6K for Magnum 6K32T MIBs for Snmp visit„ Managed switching for high performance Ethernet LANs Features and Benefits„ Features Fiber-Built-In Example 1 Magnum 6K32T Switch for a Vlan application ApplicationsData Example 3 Redundant Application Www . GarrettCom . com Www . GarrettCom . com Installation Locating Magnum 6K32T SwitchesIeee Standard Media Type Max. Distance Port Module Fiber Connecting Ethernet MediaConnecting Fiber Optic ST-type, twist-lock CopperConnecting Single-Mode Fiber Optic Connecting Fiber Optic SC-type, Snap-InMedia Ieee Standard Twisted Pair CAT-5e 1000BASE-T F10ST Rack-mounting for 19 Retma racks, Magnum 6K32T’s Table-Top or Shelf MountingMagnum 6K32T unit. These Rack-mounting, Reverse version of the Magnum 6K32T’s 1 Dual Side-Mountings for Magnum 6K32T unitsPowering the Magnum 6K32T Managed Switch 6K32T Port Module 6KPM Installation Preparation for Installing and Removing 6KPMsRemove Chassis Cover Installing 6KPM Cards in the Magnum 6K32T 1d Top View 6KPM retaining screws hold Face PlateWww . GarrettCom . com 2g Top View 6KPM Module installed inside a 6K32T Switch Removing 6KPM Cards Firmly. .5.3a Top View 6 retaining screws shown by arrowsRemove 6KPM Card Connecting the Console Terminal to Magnum 6K32T ManagementConsole DB-9 Port Rear View of Magnum 6K32TDB-9 Console port connector Pin Signal DescriptionSwitching Functionality 1 RS-232 DB-9 Console Com port Serial port pin assignmentsPWR Status LEDsACT Auto-Cross MDIXAuto-negotiation, for 10/100Mbps RJ-45 ports Www . GarrettCom . com Magnum 6K32T Managed Switch Port Modules Flow-control, Ieee 802.3x standard6KPM Module Description 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Magnum 6KP4 Connectors and configuredAs 10Mb Half-duplex by Default for 10Mb fiber Flstfx is a combo fiberTransceivers all in one module. This Mode 100Mbps fiber opticMode SC-type connectors. It Activity ACT, Link LK,Www . GarrettCom . com Activity FULL/HALF 6KP8-MTRJPort@ 100Mbps Multi-Mode Fiber port Link7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector Small 9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port Give an advantage of placing more Small size of LC connectorsPorts on one module. The 6KP8-45 GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector@ 1000Mb Fiber SC + 2@ 100Mb SC @ 1000Mb Fiber SC12 6KM-BLNK Before Calling for AssistanceWhen Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Shipping and Packaging InformationB1.0 Specifications for Magnum 6K32T SWITCHES, DC Power Appendix B Internal DC Power Supply OptionsPower Supply Internal -48VDC Option B3.0 Applications for DC Powered Switches B4.0 InstallationB5.0 Operation Appendix C Internal DC Dual-Source Power OptionB7.0 Troubleshooting B6.0 Ordering InformationC4.0 Features and Benefits of the DUAL-SOURCE Design C5.0 Installation Example Magnum 6K32T & 6K32-48VDC C5.1 UL RequirementsC6.0 Ordering Information C7.0 Operation