Magnum 6K32 & 6K32T Managed Switch | Installation and User Guide (12/05) | |
GND: | Terminal for “earth” or ground wire connection to the hub chassis | |
Input: | Two separate sources, each at 20 - 36 VDC | |
Power Supply (Internal, 125VDC | ||
DC Power Connector: First Source: “A+”, | ||
GND: | Terminal for “earth” or ground wire connection to the hub chassis | |
Input: | Two separate sources, each at 88 - 150 VDC |
With the exception of the dual DC input power connections and the power supply, all specifications and configuration options for the Magnum 6K32T
C2.0 MAGNUM 6K32T & 6K32, with
The 6K32T &
The functionality of the Magnum 6K32T Switch
C3.0
option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four
external power connection terminals) so that power from an external source
can only flow into the unit. This allows the unit to operate whenever DC power is correctly applied to either or both of the two inputs
C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN
a)The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw its power from the DC source with the highest voltage at a given time.
b)The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input, i.e. the two DC power sources are not mixed together by the hub.
c)When one correct DC input is present, the Switch will receive power if the other DC input is absent, or even if it is connected with reverse polarity or shorted or grounded.
d)Reverse polarity connections, if they should accidentally occur on either input, will not damage the Switch or power supply internally (nor will it blow the fuse in the internal power supply) because of the blocking action of the diodes. This is true even if one input connection is
www . GarrettCom . com