Magnum 6K8-Series Industrial Field Switch Installation and User Guide (04/07)
Once the bottom of the 6K8 is rotated out, the DIN-Rail latch is not engaged and the 6K8 can be moved up and out, free of the DIN-Rail mounting..
The picture below is a front / right-side view of a DIN-Rail mounted 6K8. It shows vertical mounting of Magnum 6K8 on a DIN-Rail track for proper convection cooling of the unit. Note that there is air space in the rear, as the 6K8 unit is held out from the rear of the panel by the mounting brackets. The 6K8 design uses the case for cooling (patent pending), and needs to be mounted vertically with airflow space in the front, rear, and sides.
Fig 3.3 - Magnum 6K8 mounted vertically with DIN-Rail brackets and latches
The DIN-Rail mounting brackets and latches are optional and need to be ordered as separate items, e.g. Model # DIN-RAIL-6K8
3.3.1Installing DIN-RAIL variable brackets on Magnum 6K8 Magnum 6K8 Din-Rail kit comes along with the following-BOM:
Item | Quantity | Description | |
1 | 1 | DIN Rail Clip assy | |
2 | 2 | #10-32 x ¼ Phillip | Flat head screws with |
undercut | | | |
3 | 8 | #4-40 x 3/8 Phillip Flat head screw | |
Din-Rail kit Installation procedures:
1. Remove the back plate from Magnum 6K8 UNIT
a. There are eight screws along the edge of the unit to remove.
b..Do not re-use the old screws.
2. On the back-plate
a. Locate the indented side with 1, 11…
b. “1” indentation signify center of the mounted Din-Rail clip location.
c. Each indented locations (1-11- 111…) are ½ inches apart from the center.
Fig 1.
3. Select the height position via indented side marking.
4. Place the DIN Rail Clip assembly