| Magnum |
| Installation and User Guide | (04/07) |
| |||||||||||
| Fiber | Speed, |
| Std. | Wave | Cable | X’mitr | R’cvr | Worst | Worst* |
| typical | typical* | |||
| Port | Std. | Mode | km | - | Size | Output | Sens. | OPB, | distance |
| OPB, |
| distance | ||
Module |
| fdx | length | µm | PT , dB | PR ,dB | dB | Km, fdx |
| dB |
| Km, fdx | ||||
|
|
|
| |||||||||||||
|
|
|
| (hdx) | nm |
|
|
|
|
|
|
|
|
|
|
|
6KP4V- | 10Mb | Multi- | 2 | 850 | 62.5/125 |
| 14 | 5 |
| 17 |
| 6 |
| |||
| F10ST | FL | Mode | (2) |
| 100/140 |
| 19.5 | 5.9 |
| 23.5 |
| 7 |
| ||
|
|
|
|
|
| 50/125 |
| 19.5 | 3.4 |
| 13.5 |
| 4.8 |
| ||
| 6KPV- | 100Mb | Multi- | 2 | 1300 | 62.5/125 |
| 9.0 | 3.0 |
| 14 |
| 5 |
| ||
MST, MSC | FX | mode | (0.4) |
| 50/125 |
| 5.5 | 2.0 |
| 12 |
| 4 |
| |||
100Mb | Single- | 18+ | 1300 | 9/125 |
| 14 | 28 |
| 17.5 |
| 35 |
| ||||
FX | mode | (0.4) |
|
|
|
| ||||||||||
| 6KPV- | 100Mb | Single- | 40 | 1300 | 9/125 |
| 29 | 58 |
| 32.5 |
| 65 |
| ||
| FX | mode | (0.4) |
|
|
|
| |||||||||
| SSCL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6KPV- | 100Mb | Multi- | 2 | 1300 | 62.5/125 |
| 9.0 | 3.0 |
| 15.8 |
| 5.5 |
| ||
| MTRJ | FX | mode | (0.4) |
| 50/125 |
| 5.5 | 2.0 |
| 12.2 |
| 4.0 |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6KPV- | 100Mb | Multi- | 2 | 1300 | 62.5/125 |
| 12 | 4 |
| 16 |
| 5.7 |
| ||
| FX | mode | (0.4) |
|
|
|
| |||||||||
| MLC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
100Mb | Single- | 15+ | 1310 | 9/125 |
| 11 | 22 |
| - |
| - |
| ||||
FX | Mode | (0.4) |
|
|
|
| ||||||||||
| GBIC- | 1000Mb | Multi- | 0.55 | 850 | 62.5/125 |
| 5.5 | 2 |
| 12.5 |
| 4 |
| ||
|
| mode |
|
|
|
|
| |||||||||
| SXSC |
|
|
| 50/125 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GBIC- | 1000Mb | Single- | 10 | 1300 | 9/125 |
| 8.5 | 17 |
| 10.5 |
| 21 |
| ||
|
| mode |
|
|
|
|
| |||||||||
LXSC10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GBIC- | 1000Mb | Single- | 25 | 1550 | 9/125 |
| 15 | 37.5 |
| 17.5 |
| 43 |
| ||
|
| mode |
|
|
|
|
| |||||||||
LXSC25 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GBIC- | 1000Mb | Single- | 40 | 1550 | 9/125 |
| 15 | 60 |
| 17.5 |
| 70 |
| ||
|
| mode |
|
|
|
|
| |||||||||
ZXSC40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GBIC- | 1000Mb | Single- | 70 | 1550 | 9/125 |
| 18 | 90 |
| 20.5 |
| 102 |
| ||
|
| mode |
|
|
|
|
| |||||||||
ZXSC70 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Note: The use of either
•The 100Mb fiber segment must operate in
•The
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
www . GarrettCom . com
48