GE FVR-C9S-7UX instruction manual External Dimensions

Page 10

FVR-C9S-7UX

5. External Dimensions

4.72 (120)

0.26(6.5)

0.06(1.5)

1.97 (50)

2.76 (70)

0.39 (10)

 

 

0.24 (6.2)

 

D

3.15 (80)

 

 

 

D2

 

 

 

 

2.64 (67)

0.26 (6.5)

 

 

 

(5)0.20

(10)0.39

 

 

2 - 0.20 X 0.24

 

0.06 (1.5)

 

 

 

(2 - 5 X 6.2)

 

 

 

 

 

 

 

0.24 (6.2)

 

 

4.33 (110)

3.94 (100)

 

 

0.43 (11)

0.20(5)

(10)0.39

TERMINAL M3.5

 

 

 

 

 

 

 

 

 

0.06 (1.5)

 

 

D1

 

 

 

 

2.36 (50)

0.39 (10)

 

 

 

DWG 1: FVRF12C9S-7UX to FVROO1C9S-7UX

 

 

Rated Current

 

External Dimensions: inches (mm)

DWG No.

Type

[A]

 

D

D1

D2

 

FVRF12C9S-7UX

0.66

 

3.37 (85.5)

0.89 (22.5)

0.39 (10)

 

FVRF25C9S-7UX

1.2

 

3.56 (90.5)

1.08 (27.5)

0.59 (15)

DWG 1

FVRF50C9S-7UX

2.1

 

 

3.96 (100.5)

1.48 (37.5)

0.98 (25)

 

 

 

 

FVR001C9S-7UX

3.7

 

 

5.53 (140.5)

2.46 (62.5)

1.97 (50)

 

 

 

 

 

 

 

 

 

10

Image 10
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Fire and Personal Injury HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names Specifications Supply voltage 3%Setting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Installation Conditions Installation InstructionsWiring Mounting Direction and SpaceRequired for CE Certification Basic Wiring Diagram Keypad Panel OperationExternal Signal Operation 50/60Hz PhaseApplication of Wiring and Equipment Mccb ElcbTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Pre-Operation Inspection Frequency Setting MethodOperation Test Run Check PointsSelecting Operation Method RUN/STOPPart Names and Functions Keypad PanelControlling Method for Keypad Panel Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code 8 Electronic Thermal Overload Relay Torque BoostElectronic Thermal Overload Relay Level Current 2 DC Brake 1 Gain for Frequency Setting Signal3 DC Brake Braking Time 4 Starting Frequency 6 Fault Memory5 Motor Running Sound 8 Retry 9 Motor Characteristics7 Data Initialization Jump Frequency Range7 THR Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 8 BX Terminal FunctionMultistep Speed Setting 2 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 3 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Out-of-Warranty Procedures Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageGeneral Recommended Installation InstructionsElectromagnetic Compatibility EMC RFI FiltersLine Enclosure Noise filterRFI FVR-C9S-7UX EC Declaration of Conformity Product identificationEC Declaration of Conformity FVR-C9S-7UX