GE FVR-C9S-7UX instruction manual Operation Electric Shock Hazard

Page 5

FVR-C9S-7UX

CAUTION:

Check that the phase and voltage of the AC power supply being connected matches the input phase and rated input voltage of the drive. Using an improper power supply may cause injury or damage to the equipment.

Do not connect AC power to the output termi- nals (U, V, W) otherwise injury may result.

The drive, motor and wiring produce electromag- netic noise during operation. Make sure that this does not interfere with the operation of sensors or other equipment nearby, otherwise accidents may result.

OPERATION

WARNING:

ELECTRIC SHOCK HAZARD

Always install the drive cover before turning on the power supply. In addition, do not remove the drive cover while the power is on. Failure to observe these precautions may result in electric shocks.

Do not operate any of the switches with wet hands, otherwise electric shocks may result.

WARNING:

FIRE AND PERSONAL INJURY HAZARD

If the retry function has been activated and a trip occurs, the drive will restart automatically de- pending on the cause of the trip. Make sure that the system is set up properly so that there will be no danger to personnel when the drive starts.

The STOP key is only effective when keypad panel operation has been selected in the func- tion settings. A separate switch should be installed for emergency stopping purposes.

If an alarm reset is carried out while a run signal (FWD/REV) is being input, the drive will suddenly restart. Always check that the run signal is not being input before carrying out the alarm reset, otherwise accidents may occur.

Never touch the drive terminals while the power is fed to the drive, regardless of whether the drive is running or not.

CAUTION:

Do not touch the cooling fins, as they become hot during drive operation.

Because it is relatively easy to set the drive to high speed operation, be sure to check the capacity of the motor and the equipment being operated before changing the drive function setting.

The drive braking function cannot be substituted for mechanical means. Attempting to do so may result in injury.

MAINTENANCE, INSPECTION AND PART REPLACEMENT

WARNING:

ELECTRIC SHOCK HAZARD

Wait at least five minutes after turning off the power before carrying out inspection. Check that the charge indication lamp has gone out. Do not touch the drive parts if the lamp is still lit, other- wise electric shocks may result.

Maintenance, inspection and parts replacement should only be carried out by suitably qualified personnel. Remove any metallic accessories such as watches and rings before starting work, and use only properly insulated tools, otherwise electric shocks may result.

DISPOSAL

CAUTION

Disposal of the drive should be entrusted to a suitably-qualified disposal agency, otherwise injury may result.

PACKING

CAUTION

Do not stand or sit on the drive as injury may result.

The number of packing cartons that can be stacked together is printed on the packing container. Do not stack the containers any higher than this or injury may result.

5

Image 5
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Fire and Personal Injury Hazard Safety PrecautionsOperation Electric Shock Hazard Nameplate Inspection Upon ReceiptPart Names Supply voltage 3% SpecificationsSetting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Wiring Installation InstructionsInstallation Conditions Mounting Direction and SpaceRequired for CE Certification Keypad Panel Operation Basic Wiring Diagram50/60Hz Phase External Signal OperationMccb Elcb Application of Wiring and EquipmentTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Operation Frequency Setting MethodPre-Operation Inspection Test Run Check PointsRUN/STOP Selecting Operation MethodControlling Method for Keypad Panel Keypad PanelPart Names and Functions Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code Electronic Thermal Overload Relay Level Torque Boost8 Electronic Thermal Overload Relay Current 3 DC Brake Braking Time 1 Gain for Frequency Setting Signal2 DC Brake 5 Motor Running Sound 6 Fault Memory4 Starting Frequency 7 Data Initialization 9 Motor Characteristics8 Retry Jump Frequency Range6 Bias Frequency 4 High Limiter F 2 5 Low Limiter7 THR Terminal Function 8 BX Terminal FunctionMultistep Speed Setting 3 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 2 Speed 3 FM Terminal Function Selection 2 FM Terminal Output Level CalibrationOC3 Protective FunctionsTechnical Services GE Fuji Drives USA, Inc Warranty Parts and ServiceOut-of-Warranty Procedures MotorsLatest Fault Previous Faults No Message In-Warranty Failure ChecklistElectromagnetic Compatibility EMC Recommended Installation InstructionsGeneral RFI FiltersLine Noise filter EnclosureRFI FVR-C9S-7UX Product identification EC Declaration of ConformityEC Declaration of Conformity FVR-C9S-7UX