GE FVR-C9S-7UX instruction manual Safety Precautions, Fire and Personal Injury Hazard

Page 4

FVR-C9S-7UX

0. Safety Precautions

Before carrying out installation, wiring, mainte- nance or inspection of the drive, read this in- struction manual thoroughly to gain a full under- standing of the correct operation procedures. Make sure that you have read all product details, safety information, warnings and cautions before use. The following classifications for warnings and cautions are used throughout this manual.

WARNING:

Denotes operating procedures and practices that may result in severe injury or loss of life if not correctly followed.

CAUTION:

Denotes operating procedures and practices that, if not strictly observed, may result in per- sonal injury or damage to the equipment.

WARNING:

FIRE AND PERSONAL INJURY HAZARD

This drive is designed for variable-speed opera- tion of three-phase induction motors. It cannot be used with single-phase motors or for any other applications, otherwise fire may result.

The drive cannot be used by itself for elevators, life-preservation equipment or other equipment which is directly related to human safety. In such situations, sufficient consideration should be given to overall system configuration, not just to the drive, otherwise serious accidents could result.

INSTALLATION

WARNING:

FIRE AND PERSONAL INJURY HAZARD

Install the drive to a non-flammable surface such as a metal surface, otherwise fires may result.

Do not place the drive near flammable materials, otherwise fires may result.

Do not hold the drive by its cover when trans- porting. Otherwise the drive could be damaged and cause injury to personnel.

Do not let any scraps of thread, paper, sawdust, dirt, metal shavings or other foreign objects get

inside the drive or onto the cooling fins, other- wise fire or problems with operation may result. AC input fuses are required to validate UL listing of this device.

Do not install and operate the drive if it is dam- aged or if some of the parts are missing. Doing so may result in severe personal injury.

Do not touch the drive cooling fin because the cooling fin reaches high temperatures during operation, otherwise personal injury may result.

Install the drive in the environment of pollution degree 2. If environment is pollution degree 3 or 4, the drive should be installed in a cabinet of IP54. Required for CE Certification.

WIRING

WARNING:

FIRE AND ELECTRIC SHOCK HAZARD.

When connecting the drive to a power supply, be sure to connect it via a circuit breaker, a leakage current breaker or a fuse, otherwise fires may result.

AC input fuses are required to validate the UL listing of the drive.

Use only fuses and circuit breakers with rated capacities that are suitable for use with the drive. Failure to do so may result in fire.

Connect the drive with a secure ground, other- wise electric shocks or fires may result.

Wiring work should only be carried out by suit- ably qualified personnel, otherwise electric shocks may result.

Make absolutely sure that the power supply is turned off (open) before wiring, otherwise electric shocks may result.

Wiring work should only be carried out after the drive has been installed, otherwise electric shocks or injury may result.

4

Image 4
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Fire and Personal Injury HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names Specifications Supply voltage 3%Setting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Installation Instructions WiringInstallation Conditions Mounting Direction and SpaceRequired for CE Certification Basic Wiring Diagram Keypad Panel OperationExternal Signal Operation 50/60Hz PhaseApplication of Wiring and Equipment Mccb ElcbTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Frequency Setting Method OperationPre-Operation Inspection Test Run Check PointsSelecting Operation Method RUN/STOPPart Names and Functions Keypad PanelControlling Method for Keypad Panel Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code 8 Electronic Thermal Overload Relay Torque BoostElectronic Thermal Overload Relay Level Current 2 DC Brake 1 Gain for Frequency Setting Signal3 DC Brake Braking Time 4 Starting Frequency 6 Fault Memory5 Motor Running Sound 9 Motor Characteristics 7 Data Initialization8 Retry Jump Frequency Range4 High Limiter F 2 5 Low Limiter 6 Bias Frequency7 THR Terminal Function 8 BX Terminal FunctionMultistep Speed Setting 2 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 3 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Warranty Parts and Service Technical Services GE Fuji Drives USA, IncOut-of-Warranty Procedures MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageRecommended Installation Instructions Electromagnetic Compatibility EMCGeneral RFI FiltersLine Enclosure Noise filterRFI FVR-C9S-7UX EC Declaration of Conformity Product identificationEC Declaration of Conformity FVR-C9S-7UX