GE FVR-C9S-7UX instruction manual Specifications, Supply voltage 3%

Page 8

FVR-C9S-7UX

4. Specifications

Type (FVR _ _ _ C9S-7UX)

 

 

F12

 

F25

F50

 

001

 

002

Applicable motor output1

 

[Hp]

1/8

 

1/4

1/2

 

1

 

2

 

Rated capacity2

 

[kVA]

0.27

 

0.5

0.87

 

1.5

 

2.7

 

Voltage

 

[V]

Three-phase 220-240V 50/60 Hz (Output voltage is proportional

 

 

 

 

to input voltage)

 

 

 

 

 

 

Output Rating

Rated current

 

[A]

0.66

 

1.2

2.1

 

3.7

 

6.4

 

Overload current rating

 

150% 1 min.

 

 

 

 

 

 

 

Rated frequency

 

[Hz]

50/60 Hz

 

 

 

 

 

 

 

Phase, voltage, frequency

 

Single-phase 220-240V 50/60 Hz

 

 

 

 

Allowable variation in

 

Voltage: =10 - 15% Frequency: 15% (Imbalance in power

 

Input power

voltage/frequency

 

 

supply voltage: 3%)

 

 

 

 

 

supply

Instantaneous voltage drop

 

Drive is kept running if voltage is 165V or more. If voltage drops

 

withstanding capacity

 

more than 165V from rated voltage, drive is run for 15ms.3

 

 

Required power supply

[kVA]

0.3

 

0.6

1.0

 

1.7

 

3.1

 

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment

Max. freq.4

[Hz]

50-120 Hz Setting variable (in increments of 1 Hz)

 

 

 

Base freq.

[Hz]

50-120 Hz Setting variable (in increments of 1 Hz)

 

 

Starting freq.

[Hz]

1-6 Hz Setting variable (in increments of 1 Hz)

 

Output

Accuracy

 

 

Analog setting: ±1.0% of max. frequency (25±10°C)

 

frequency

 

 

 

Digital setting: ±0.01% of max. frequency (-10 - +50°C)

 

 

Setting resolution

 

 

Analog setting:1/255 of max. frequency

 

 

 

 

 

 

 

 

(ex. 0.25 Hz / 60 Hz, 0.5 Hz / 120 Hz)

 

 

 

 

 

Digital Setting: 0.1 Hz (99.9 Hz max) 1 Hz (100-120 Hz)

 

 

Control method

 

 

Sine wave PWM control

 

 

 

 

 

 

 

 

 

(Extremely low noise by high frequency carrier)

 

Control

Operation

 

 

Keypad operation:

Operation control by RUN/STOP keys

 

 

 

 

Terminal strip:

 

Forward command. Reverse command.

 

 

 

 

 

 

 

Coast-to-stop command. Reset.

 

 

 

 

 

 

 

 

External alarm.

 

 

 

1) "Applicable motor" indicates a standard 4-pole motor.

 

 

 

 

 

C92-7-13

 

 

 

 

 

 

2)"Rated capacity" indicates a capacity at 240V rating.

3)This applies to the case where momentary power failure occurs under such conditions that rated voltage is inputted and load factor is 85%.

4)Shows the case where an applicable motor equipped with an AC reactor (option) on the input side is used.

8

Image 8
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Fire and Personal Injury HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names Specifications Supply voltage 3%Setting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Installation Instructions WiringInstallation Conditions Mounting Direction and SpaceRequired for CE Certification Basic Wiring Diagram Keypad Panel OperationExternal Signal Operation 50/60Hz PhaseApplication of Wiring and Equipment Mccb ElcbTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Frequency Setting Method OperationPre-Operation Inspection Test Run Check PointsSelecting Operation Method RUN/STOPControlling Method for Keypad Panel Keypad PanelPart Names and Functions Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code Electronic Thermal Overload Relay Level Torque Boost8 Electronic Thermal Overload Relay Current 3 DC Brake Braking Time 1 Gain for Frequency Setting Signal2 DC Brake 5 Motor Running Sound 6 Fault Memory4 Starting Frequency 9 Motor Characteristics 7 Data Initialization8 Retry Jump Frequency Range4 High Limiter F 2 5 Low Limiter 6 Bias Frequency7 THR Terminal Function 8 BX Terminal FunctionMultistep Speed Setting 3 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 2 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Warranty Parts and Service Technical Services GE Fuji Drives USA, IncOut-of-Warranty Procedures MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageRecommended Installation Instructions Electromagnetic Compatibility EMCGeneral RFI FiltersLine Enclosure Noise filterRFI FVR-C9S-7UX EC Declaration of Conformity Product identificationEC Declaration of Conformity FVR-C9S-7UX