GE FVR-C9S-7UX instruction manual Enclosure, Noise filter

Page 39

FVR-C9S-7UX

Basic Standards: EN55011 Class B

Single phase 50/60 Hz power supply

Input

 

 

 

Enclosure

 

contactor

 

 

 

 

 

 

 

HRC Fuses

 

 

 

Ferrite ring

 

Noise filter

 

1 turn

Screen

or circuit

 

breaker

(foot mounted)

Drive

 

 

L

L’

L1

U

 

 

N

N’

L2

V

 

 

W

 

 

PE

 

 

E

 

 

 

*2

 

 

*1

 

 

 

 

 

 

 

Screening must be electrically continuous and earthed at the enclosure and the motor.

*1and *2: These connections are to be as short as possible and earth conductor should be as thick as possible.

39

Image 39
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Fire and Personal Injury Hazard Safety PrecautionsOperation Electric Shock Hazard Nameplate Inspection Upon ReceiptPart Names Supply voltage 3% SpecificationsSetting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Mounting Direction and Space Installation InstructionsWiring Installation ConditionsRequired for CE Certification Keypad Panel Operation Basic Wiring Diagram50/60Hz Phase External Signal OperationMccb Elcb Application of Wiring and EquipmentTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Test Run Check Points Frequency Setting MethodOperation Pre-Operation InspectionRUN/STOP Selecting Operation MethodKeypad Panel Part Names and FunctionsControlling Method for Keypad Panel Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code Torque Boost 8 Electronic Thermal Overload RelayElectronic Thermal Overload Relay Level Current 1 Gain for Frequency Setting Signal 2 DC Brake3 DC Brake Braking Time 6 Fault Memory 4 Starting Frequency5 Motor Running Sound Jump Frequency Range 9 Motor Characteristics7 Data Initialization 8 Retry8 BX Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 7 THR Terminal FunctionMultistep Speed Setting 1 Speed Multistep Speed Setting 2 SpeedMultistep Speed Setting 3 Speed 3 FM Terminal Function Selection 2 FM Terminal Output Level CalibrationOC3 Protective FunctionsMotors Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc Out-of-Warranty ProceduresLatest Fault Previous Faults No Message In-Warranty Failure ChecklistRFI Filters Recommended Installation InstructionsElectromagnetic Compatibility EMC GeneralLine Noise filter EnclosureRFI FVR-C9S-7UX Product identification EC Declaration of ConformityEC Declaration of Conformity FVR-C9S-7UX