GE FVR-C9S-7UX instruction manual Motor Running Code

Page 24

FVR-C9S-7UX

Function Code Tables

Function

Function

 

Date Code Range

Unit

Min.

Factory

Change

 

During

Code

 

Set.

Setting

 

 

 

 

Operation

 

 

 

 

 

 

 

 

F15

Motor Running

0

- 5 (code)

5

 

Yes

Sound

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F16

Fault Memory

The current and previous 3 fault events are displayed

No

in order of occurrence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F17

Data Initialization

0: Inactive

0

 

No

1: Reset to the initial value (value set at factory)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Inactive

 

 

 

 

 

F18

Retry

1: Active (Retry times fixed at 5, Retry starts in

0

 

No

 

 

.05s after trip)

 

 

 

 

 

F19

Motor

0

- 10

4

 

Yes

Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F20

Jump Frequency

0

- 10Hz

Hz

1

3

 

Yes

Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F21

Jump Frequency 1

0

- 120Hz

Hz

1

0

 

Yes

 

 

 

 

 

 

 

 

 

F22

Jump Frequency 2

0

- 120 Hz

Hz

1

0

 

Yes

 

 

 

 

 

 

 

 

 

F23

Jump Frequency 3

0

- 120 Hz

Hz

1

0

 

Yes

 

 

 

 

 

 

 

 

F24

High Limiter

0

- 100%

%

1

100

Yes

 

 

 

 

 

 

 

 

 

F25

Low Limiter

0

- 100%

%

1

0

 

Yes

 

 

 

 

 

 

 

 

 

F26

Bias Setting

0

- 100%

%

1

0

 

Yes

 

 

 

 

 

 

 

 

F27

THR Terminal

0: External alarm input

0

 

No

Function

1: Multistep speed selection (X1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F28

BX Terminal

0: Motor coast-to-stop command input

0

 

No

Function

1: Multistep speed selection (X2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F29

Multistep Speed

0.0 - 120 Hz

Hz

1*

10.0

Hz

Yes

Setting 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F30

Multistep Speed

0.0 - 120 Hz

Hz

1*

20.0

Hz

Yes

Setting 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F31

Multistep Speed

0.0 - 120 Hz

Hz

1*

30.0

Hz

Yes

Setting 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F32

Meter Adjustment

0

- 99 (Full scale DC 6.5 - 10.5V)

1

85

 

Yes

 

 

 

 

 

 

 

 

F33

Meter Output

0: Output frequency monitor

1

0

 

Yes

selection

1: Output current monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Frequency can be set in increments of 0.1 Hz within a range of 0.0 to 99.9 Hz, and can be set in increments of 1 Hz

C92-02

 

24

Image 24
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Fire and Personal Injury HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names Specifications Supply voltage 3%Setting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Installation Instructions WiringInstallation Conditions Mounting Direction and SpaceRequired for CE Certification Basic Wiring Diagram Keypad Panel OperationExternal Signal Operation 50/60Hz PhaseApplication of Wiring and Equipment Mccb ElcbTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Frequency Setting Method OperationPre-Operation Inspection Test Run Check PointsSelecting Operation Method RUN/STOPKeypad Panel Part Names and FunctionsControlling Method for Keypad Panel Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code Torque Boost 8 Electronic Thermal Overload RelayElectronic Thermal Overload Relay Level Current 1 Gain for Frequency Setting Signal 2 DC Brake3 DC Brake Braking Time 6 Fault Memory 4 Starting Frequency5 Motor Running Sound 9 Motor Characteristics 7 Data Initialization8 Retry Jump Frequency Range4 High Limiter F 2 5 Low Limiter 6 Bias Frequency7 THR Terminal Function 8 BX Terminal FunctionMultistep Speed Setting 1 Speed Multistep Speed Setting 2 SpeedMultistep Speed Setting 3 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Warranty Parts and Service Technical Services GE Fuji Drives USA, IncOut-of-Warranty Procedures MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageRecommended Installation Instructions Electromagnetic Compatibility EMCGeneral RFI FiltersLine Enclosure Noise filterRFI FVR-C9S-7UX EC Declaration of Conformity Product identificationEC Declaration of Conformity FVR-C9S-7UX