8. Basic Wiring Diagram

1) Keypad Panel Operation

From the factory, the drive is set for frequency control by means of the potentiometer control knob on the keypad panel. The RUN/STOP function of the drive is controlled by the RUN/ STOP keys on the keypad panel.

Power Supply

AC220 - 240V

50/60 Hz

1-phase

FAB

L1

 

U

8 8 8

V

M

L2

W

 

 

 

13

CN2

 

12

E(G)

 

 

 

11

Fault

 

C1

 

30A

 

 

FWD

 

30B

 

30C

REV

 

RST

 

 

BX

 

 

CM

 

 

THR

 

 

FM

 

 

10V 1mA

PE

*PE terminal blocks for the drive and motor should be provided in the cabinet in which the drive is installed in.

14

Image 14
Contents FVR-C9S-7UX Drive Series Product specifications are subject to change without notice Contents Safety Precautions Fire and Personal Injury HazardOperation Electric Shock Hazard Inspection Upon Receipt NameplatePart Names Specifications Supply voltage 3%Setting with UP/DOWN keys External Dimensions DWG 2 FVR002C9S-7UX Installation Conditions Installation InstructionsWiring Mounting Direction and SpaceRequired for CE Certification Basic Wiring Diagram Keypad Panel OperationExternal Signal Operation 50/60Hz PhaseApplication of Wiring and Equipment Mccb ElcbTerminal Function Explanation Terminal Function ExplanationClassi Terminal Code Terminal Name Explanation of Function Pre-Operation Inspection Frequency Setting MethodOperation Test Run Check PointsSelecting Operation Method RUN/STOPControlling Method for Keypad Panel Keypad PanelPart Names and Functions Method Operation Procedure Display Function Code Tables Motor Running Code Detailed Explanation of Each Function Code Electronic Thermal Overload Relay Level Torque Boost8 Electronic Thermal Overload Relay Current 3 DC Brake Braking Time 1 Gain for Frequency Setting Signal2 DC Brake 5 Motor Running Sound 6 Fault Memory4 Starting Frequency 8 Retry 9 Motor Characteristics7 Data Initialization Jump Frequency Range7 THR Terminal Function 4 High Limiter F 2 5 Low Limiter6 Bias Frequency 8 BX Terminal FunctionMultistep Speed Setting 3 Speed Multistep Speed Setting 1 SpeedMultistep Speed Setting 2 Speed 2 FM Terminal Output Level Calibration 3 FM Terminal Function SelectionProtective Functions OC3Out-of-Warranty Procedures Warranty Parts and ServiceTechnical Services GE Fuji Drives USA, Inc MotorsIn-Warranty Failure Checklist Latest Fault Previous Faults No MessageGeneral Recommended Installation InstructionsElectromagnetic Compatibility EMC RFI FiltersLine Enclosure Noise filterRFI FVR-C9S-7UX EC Declaration of Conformity Product identificationEC Declaration of Conformity FVR-C9S-7UX