ICP DAS USA DN-3000, DB25, 100-700 PLCS user manual Project Types

Page 11

Creating Project Files

“PROJECT

TYPE”

List

PROJECT TYPES

DeviceNet to PLCs or Devices allows a DeviceNet Host to read and write registers in up to 32 PLCs or devices.

DeviceNet to Motor Drives allows a DeviceNet Host to control and/or monitor up to 32 supported Motor Drives.

5

Image 11
Contents DN-3000 Page Warranty Warranty & NoticesTable of Contents Application Notes Motor Drives Page Introduction IntroductionGeneral Information Software InstallationInstallation Software START-UP Software InformationCreating a Project File Creating Project FilesProject Types Additional Project Menu Sub-Headings Device Profile DeviceNet to PLCs or DevicesDevicenet to Plcs or Devices DeviceNet Host to Multi-Dropped Serial PLCs Example ApplicationsDeviceNet Host to Serial PLC with Pass-Through Connection Multiple DN-3000s with Different PLC or Device Types DeviceNet to PLCs or Devices Edit Menu Configuring Port #1, DevicenetMAC ID of DN3000 PLC/Device Protocol Configuring Port #2 Plcs or DevicesWire RS422 or RS485 Communications Intermessage Time-Out Configuring Port # 3 PassthroughUse I/O Data Data ConfigurationOutput Data Use Command BlockUse Diagnostics Output Data SizeInput Data Input Data SizeOutput Data Table Register Number Use Output WordPLC/Device Address File Number Allen-Bradley PLCs onlyInput Data Table PLC/DeviceAddress Use Input WordCommand Block Devicenet to Motor Drives DeviceNet to Motor DrivesDeviceNet Host to Multi-Dropped Serial Motor Drives DeviceNet Host to Serial Motor DriveMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Motor Drive Type Configuring Port # 2 Motor DrivesMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Parameter Number Motor Drive AddressInput Data Table Use Input Word Number Word Returned Parameter Data read command only Word Motor Drive Address CommandNumber Word Parameter Data write command only Word Motor Drive Address Result Code CommandOperation of the Link Switch Upper Link Configuration Mitsubishi Drives OnlyException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesVerify Transfer OptionsDownload Project to DN3000 Upload Project from DN3000SET Directory Options SettingsOptions Settings Current Directory Path Graphic Area SET COM Port Save Options to Disk Default OptionsSET Printer Options Load Options from DiskTechnical Information Power RequirementsPhysical Dimensions Switch # Normal Off Configuration Diagnostic DIP Switch SettingsVisual LED Indicators Flashes followed by a pause DN-3000 Troubleshooting InformationFlashes followed by a pause Invalid DIP Switch Setting Protocols Supported Registers AccessedApplication Notes PLCs and Devices ALLEN-BRADLEY PLC 5, SLC500 and Micrologix PlcsLink Adapter Requirement Idec MICRO-3 PlcsIdec FA Series Plcs Koyo / PLC Direct 205 Series Plcs Memory Address PLC Registers AccessedKoyo / PLC Direct / TI 305 Series Plcs RTS Control Mitsubishi FX Series PlcsModicon Plcs and Modbus Devices Omron PlcsPass-Through Port Protocol InformationPassthrough Port Note Square D Model 100-700 PlcsWestinghouse Plcs Toshiba EX and M Series PlcsToshiba T Series Plcs Drive Parameter Numbers Assigned By Panel-Tec Application Notes Motor DrivesBaldor Motor Drives Drive Addresses Assigned By Panel-Tec Configuring a Baldor Drive For Serial CommunicationsYaskawa Motor Drives Configuring a Woods Drive For Serial CommunicationsMitsubishi Motor Drives Woods Motor DrivesDN3000 Configuration Cable Cable DiagramsSolder End Allen BradleyGE Fanuc DN3000 GE Fanuc 90/20, 30Idec Koyo/PLC Direct Mitsubishi Mitsubishi FX SeriesModicon ModiconHost Link OmronSiemens S7 TSX07 Square DTI5 232 Port DN3000 Simatic TI5 SeriesToshiba DN3000 ToshibaBaldor Baldor Motor DrivesMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet DN3000 DeviceNet Cable