ICP DAS USA DB25, 100-700 PLCS SET Printer Options, Load Options from Disk, Save Options to Disk

Page 51

Options Settings

SET PRINTER OPTIONS

To change the printer port (default = LPT 1) setting, move the highlight bar to the “Setup Printer” sub- heading and press the ENTER key. When the “Setup Printer” screen appears (see following page), use the arrow keys to highlight the “LPTx” or “FILE” setting as required and press the SPACE BAR to enter your selection. To print to a file, enter the drive\directory\file name and press the ALT+S keys (saves this entry) and then the ESC key to return to the “OPTIONS” menu.

Print File

Setup

Window

LOAD OPTIONS FROM DISK

The “Load Options from Disk” option will retrieve the options settings that were last saved to disk using “Save Options to Disk”.

SAVE OPTIONS TO DISK

The “Save Options to Disk” option will save all currently selected options settings to disk. The next time the configuration software is loaded, these options will automatically be loaded from disk during startup.

DEFAULT OPTIONS

The “Default Options” option is a quick way to reset all option settings to the original configuration software default settings for directory, communications port and printer options.

45

Image 51
Contents DN-3000 Page Warranty Warranty & NoticesTable of Contents Application Notes Motor Drives Page Introduction IntroductionSoftware Installation InstallationGeneral Information Software START-UP Software InformationCreating a Project File Creating Project FilesProject Types Additional Project Menu Sub-Headings DeviceNet to PLCs or Devices Devicenet to Plcs or DevicesDevice Profile Example Applications DeviceNet Host to Serial PLC with Pass-Through ConnectionDeviceNet Host to Multi-Dropped Serial PLCs Multiple DN-3000s with Different PLC or Device Types DeviceNet to PLCs or Devices Edit Menu Configuring Port #1, DevicenetMAC ID of DN3000 PLC/Device Protocol Configuring Port #2 Plcs or DevicesWire RS422 or RS485 Communications Intermessage Time-Out Configuring Port # 3 PassthroughUse I/O Data Data ConfigurationOutput Data Use Command BlockUse Diagnostics Output Data SizeInput Data Input Data SizeOutput Data Table Register Number Use Output WordPLC/Device Address File Number Allen-Bradley PLCs onlyInput Data Table PLC/DeviceAddress Use Input WordCommand Block Devicenet to Motor Drives DeviceNet to Motor DrivesDeviceNet Host to Multi-Dropped Serial Motor Drives DeviceNet Host to Serial Motor DriveMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Motor Drive Type Configuring Port # 2 Motor DrivesMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Parameter Number Motor Drive AddressInput Data Table Use Input Word Number Word Returned Parameter Data read command only Word Motor Drive Address CommandNumber Word Parameter Data write command only Word Motor Drive Address Result Code CommandOperation of the Link Switch Upper Link Configuration Mitsubishi Drives OnlyException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesVerify Transfer OptionsDownload Project to DN3000 Upload Project from DN3000Options Settings Options SettingsSET Directory Current Directory Path Graphic Area SET COM Port Save Options to Disk Default OptionsSET Printer Options Load Options from DiskPower Requirements Physical DimensionsTechnical Information DIP Switch Settings Visual LED IndicatorsSwitch # Normal Off Configuration Diagnostic DN-3000 Troubleshooting Information Flashes followed by a pause Invalid DIP Switch SettingFlashes followed by a pause Protocols Supported Registers AccessedApplication Notes PLCs and Devices ALLEN-BRADLEY PLC 5, SLC500 and Micrologix PlcsIdec MICRO-3 Plcs Idec FA Series PlcsLink Adapter Requirement Koyo / PLC Direct 205 Series Plcs Memory Address PLC Registers AccessedKoyo / PLC Direct / TI 305 Series Plcs RTS Control Mitsubishi FX Series PlcsModicon Plcs and Modbus Devices Omron PlcsPass-Through Port Protocol InformationPassthrough Port Note Square D Model 100-700 PlcsToshiba EX and M Series Plcs Toshiba T Series PlcsWestinghouse Plcs Application Notes Motor Drives Baldor Motor DrivesDrive Parameter Numbers Assigned By Panel-Tec Drive Addresses Assigned By Panel-Tec Configuring a Baldor Drive For Serial CommunicationsYaskawa Motor Drives Configuring a Woods Drive For Serial CommunicationsMitsubishi Motor Drives Woods Motor DrivesDN3000 Configuration Cable Cable DiagramsSolder End Allen BradleyGE Fanuc DN3000 GE Fanuc 90/20, 30Idec Koyo/PLC Direct Mitsubishi Mitsubishi FX SeriesModicon ModiconHost Link OmronSiemens S7 TSX07 Square DTI5 232 Port DN3000 Simatic TI5 SeriesToshiba DN3000 ToshibaBaldor Baldor Motor DrivesMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet DN3000 DeviceNet Cable