ICP DAS USA DN-3000, DB25, 100-700 PLCS user manual Input Data Table

Page 41

DeviceNet to Motor Drives

INPUT DATA TABLE

Within the “I/O Data Configuration” screen, use the DOWN arrow key to move the focus to the Input Data button and press the ENTER key. This action opens the Input Data Table setup screen to allow you to set up the motor drive parameters to be mapped to each word of Input data.

Input data is data read from motor drive parameters and sent from the DN-3000 to the DeviceNet Host. Each word of Input data (except those reserved for the Command Block and Diagnostics) can be mapped to specific motor drive parameters. Mapped motor drive parameters in the Input Data Table are read from the motor drives and placed in the Input data in a round-robin fashion as quickly as the motor drives’ serial communications link allows.

Use the UP/DOWN arrow keys to scroll through the list of Input data words until the highlight bar is over the Input word you wish to edit, and press ENTER. A window will open allowing you to edit the Motor Drive Address and Parameter Number mapped to that Input word.

35

Image 41
Contents DN-3000 Page Warranty Warranty & NoticesTable of Contents Application Notes Motor Drives Page Introduction IntroductionGeneral Information Software InstallationInstallation Software START-UP Software InformationCreating a Project File Creating Project FilesProject Types Additional Project Menu Sub-Headings Device Profile DeviceNet to PLCs or DevicesDevicenet to Plcs or Devices DeviceNet Host to Multi-Dropped Serial PLCs Example ApplicationsDeviceNet Host to Serial PLC with Pass-Through Connection Multiple DN-3000s with Different PLC or Device Types DeviceNet to PLCs or Devices Edit Menu Configuring Port #1, DevicenetMAC ID of DN3000 PLC/Device Protocol Configuring Port #2 Plcs or DevicesWire RS422 or RS485 Communications Intermessage Time-Out Configuring Port # 3 PassthroughUse I/O Data Data ConfigurationUse Diagnostics Use Command BlockOutput Data Size Output DataInput Data Input Data SizeOutput Data Table PLC/Device Address Use Output WordFile Number Allen-Bradley PLCs only Register NumberInput Data Table PLC/DeviceAddress Use Input WordCommand Block Devicenet to Motor Drives DeviceNet to Motor DrivesDeviceNet Host to Multi-Dropped Serial Motor Drives DeviceNet Host to Serial Motor DriveMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Motor Drive Type Configuring Port # 2 Motor DrivesMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Parameter Number Motor Drive AddressInput Data Table Use Input Word Number Word Parameter Data write command only Word Motor Drive Address CommandWord Motor Drive Address Result Code Command Number Word Returned Parameter Data read command onlyOperation of the Link Switch Upper Link Configuration Mitsubishi Drives OnlyException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesDownload Project to DN3000 Transfer OptionsUpload Project from DN3000 VerifySET Directory Options SettingsOptions Settings Current Directory Path Graphic Area SET COM Port SET Printer Options Default OptionsLoad Options from Disk Save Options to DiskTechnical Information Power RequirementsPhysical Dimensions Switch # Normal Off Configuration Diagnostic DIP Switch SettingsVisual LED Indicators Flashes followed by a pause DN-3000 Troubleshooting InformationFlashes followed by a pause Invalid DIP Switch Setting Application Notes PLCs and Devices Registers AccessedALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Protocols SupportedLink Adapter Requirement Idec MICRO-3 PlcsIdec FA Series Plcs Koyo / PLC Direct 205 Series Plcs Memory Address PLC Registers AccessedKoyo / PLC Direct / TI 305 Series Plcs Modicon Plcs and Modbus Devices Mitsubishi FX Series PlcsOmron Plcs RTS ControlPass-Through Port Protocol InformationPassthrough Port Note Square D Model 100-700 PlcsWestinghouse Plcs Toshiba EX and M Series PlcsToshiba T Series Plcs Drive Parameter Numbers Assigned By Panel-Tec Application Notes Motor DrivesBaldor Motor Drives Drive Addresses Assigned By Panel-Tec Configuring a Baldor Drive For Serial CommunicationsMitsubishi Motor Drives Configuring a Woods Drive For Serial CommunicationsWoods Motor Drives Yaskawa Motor DrivesDN3000 Configuration Cable Cable DiagramsSolder End Allen BradleyGE Fanuc DN3000 GE Fanuc 90/20, 30Idec Koyo/PLC Direct Mitsubishi Mitsubishi FX SeriesModicon ModiconHost Link OmronSiemens S7 TSX07 Square DTI5 232 Port DN3000 Simatic TI5 SeriesToshiba DN3000 ToshibaBaldor Baldor Motor DrivesMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet DN3000 DeviceNet Cable