KOYO / PLC DIRECT 205 SERIES PLCS

Registers Accessed

The DN-3000 can access all register types in the 205 Series PLC through the use of the V-Memory assignments shown in the following table:

V-Memory Address

PLC Registers Accessed

V00000 – V00177

Timer T0 – T177 Current Values

V01000 – V01177

Counter CT0 – CT177 Current Values

V02000 – V03777

Data Words V2000 – V3777

V04000 – V04377

Non-Volatile Data Words V4000 – V4377

V40400 – V40423

Input Points X0 – X477 (16 per V-Memory word)

V40500 – V40523

Output Points Y0 – Y477 (16 per V-Memory word)

V40600 – V40617

Control Relays C0 – C377 (16 per V-Memory word)

V41000 – V41037

Stages S0 – S777 (16 per V-Memory word)

V41100 – V41107

Timer T0 – T177 Status Bits (16 per V-Memory word)

V41140 – V41147

Counter CT0 – CT177 Status Bits (16 per V-Memory word)

Important Note: The V-Memory word numbers in the above table are shown in octal. These numbers must be converted to decimal before they are entered into the DN-3000 Configuration Software. For example, if the DN-3000 is to access register V02000, the value 2000 in octal corresponds to the value 1024 in decimal. The value 1024 is then entered into the DN-3000 Configuration Software.

KOYO / PLC DIRECT / TI 405 SERIES PLCS

Registers Accessed

The DN-3000 can access all register types in the 405 Series PLC through the use of the V-Memory assignments shown in the following table:

V-Memory Address

PLC Registers Accessed

V00000 – V00377

Timer T0 – T377 Current Values

V01000 – V01177

Counter CT0 – CT177 Current Values

V01400 – V07377

Data Words V1400 – V7377

V10000 – V17777

Data Words V10000 – V17777

V40000 – V40077

Remote I/O GX0 – GX1777 (16 per V-Memory word)

V40400 – V40423

Input Points X0 – X477 (16 per V-Memory word)

V40500 – V40523

Output Points Y0 – Y477 (16 per V-Memory word)

V40600 – V40677

Control Relays C0 – C1777 (16 per V-Memory word)

V41000 – V41077

Stages S0 – S1777 (16 per V-Memory word)

V41100 – V41117

Timer T0 – T377 Status Bits (16 per V-Memory word)

V41140 – V41147

Counter CT0 – CT177 Status Bits (16 per V-Memory word)

51

Image 57
Contents DN-3000 Page Warranty Warranty & NoticesTable of Contents Application Notes Motor Drives Page Introduction IntroductionSoftware Installation InstallationGeneral Information Software START-UP Software InformationCreating a Project File Creating Project FilesProject Types Additional Project Menu Sub-Headings DeviceNet to PLCs or Devices Devicenet to Plcs or DevicesDevice Profile Example Applications DeviceNet Host to Serial PLC with Pass-Through ConnectionDeviceNet Host to Multi-Dropped Serial PLCs Multiple DN-3000s with Different PLC or Device Types DeviceNet to PLCs or Devices Edit Menu Configuring Port #1, DevicenetMAC ID of DN3000 PLC/Device Protocol Configuring Port #2 Plcs or DevicesWire RS422 or RS485 Communications Intermessage Time-Out Configuring Port # 3 PassthroughUse I/O Data Data ConfigurationUse Diagnostics Use Command BlockOutput Data Size Output DataInput Data Input Data SizeOutput Data Table PLC/Device Address Use Output WordFile Number Allen-Bradley PLCs only Register NumberInput Data Table PLC/DeviceAddress Use Input WordCommand Block Devicenet to Motor Drives DeviceNet to Motor DrivesDeviceNet Host to Multi-Dropped Serial Motor Drives DeviceNet Host to Serial Motor DriveMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Motor Drive Type Configuring Port # 2 Motor DrivesMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Parameter Number Motor Drive AddressInput Data Table Use Input Word Number Word Parameter Data write command only Word Motor Drive Address CommandWord Motor Drive Address Result Code Command Number Word Returned Parameter Data read command onlyOperation of the Link Switch Upper Link Configuration Mitsubishi Drives OnlyException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesDownload Project to DN3000 Transfer OptionsUpload Project from DN3000 VerifyOptions Settings Options SettingsSET Directory Current Directory Path Graphic Area SET COM Port SET Printer Options Default OptionsLoad Options from Disk Save Options to DiskPower Requirements Physical DimensionsTechnical Information DIP Switch Settings Visual LED IndicatorsSwitch # Normal Off Configuration Diagnostic DN-3000 Troubleshooting Information Flashes followed by a pause Invalid DIP Switch SettingFlashes followed by a pause Application Notes PLCs and Devices Registers AccessedALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Protocols SupportedIdec MICRO-3 Plcs Idec FA Series PlcsLink Adapter Requirement Koyo / PLC Direct 205 Series Plcs Memory Address PLC Registers AccessedKoyo / PLC Direct / TI 305 Series Plcs Modicon Plcs and Modbus Devices Mitsubishi FX Series PlcsOmron Plcs RTS ControlPass-Through Port Protocol InformationPassthrough Port Note Square D Model 100-700 PlcsToshiba EX and M Series Plcs Toshiba T Series PlcsWestinghouse Plcs Application Notes Motor Drives Baldor Motor DrivesDrive Parameter Numbers Assigned By Panel-Tec Drive Addresses Assigned By Panel-Tec Configuring a Baldor Drive For Serial CommunicationsMitsubishi Motor Drives Configuring a Woods Drive For Serial CommunicationsWoods Motor Drives Yaskawa Motor DrivesDN3000 Configuration Cable Cable DiagramsSolder End Allen BradleyGE Fanuc DN3000 GE Fanuc 90/20, 30Idec Koyo/PLC Direct Mitsubishi Mitsubishi FX SeriesModicon ModiconHost Link OmronSiemens S7 TSX07 Square DTI5 232 Port DN3000 Simatic TI5 SeriesToshiba DN3000 ToshibaBaldor Baldor Motor DrivesMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet DN3000 DeviceNet Cable