Application Notes – PLCs and Devices

IDEC MICRO-3 PLCS

Registers Accessed

The DN-3000 will only access registers in the Data Register Area of PLC memory (D0 to D9999). When entering register numbers, only the offset into this area (0-9999) should be entered. For example, to access register number D1, the value 1 should be entered. To access register number D9999, the value 9999 should be entered.

Link Adapter Requirement

The DN-3000 requires an Idec Link Adapter or equivalent to be used when communicating with any of the FA Series PLCs.

IDEC FA SERIES PLCS

Registers Accessed

The DN-3000 will only access registers in the Data Register Area of PLC memory (D0 to D9999). When entering register numbers, only the offset into this area (0-9999) should be entered. For example, to access register number D1, the value 1 should be entered. To access register number D9999, the value 9999 should be entered.

Link Adapter Requirement

The DN-3000 requires an Idec Link Adapter or equivalent to be used when communicating with any of the FA Series PLCs.

50

Image 56
Contents DN-3000 Page Warranty & Notices WarrantyTable of Contents Application Notes Motor Drives Page Introduction IntroductionGeneral Information Software InstallationInstallation Software Information Software START-UPCreating Project Files Creating a Project FileProject Types Additional Project Menu Sub-Headings Device Profile DeviceNet to PLCs or DevicesDevicenet to Plcs or Devices DeviceNet Host to Multi-Dropped Serial PLCs Example ApplicationsDeviceNet Host to Serial PLC with Pass-Through Connection Multiple DN-3000s with Different PLC or Device Types Configuring Port #1, Devicenet DeviceNet to PLCs or Devices Edit MenuMAC ID of DN3000 Configuring Port #2 Plcs or Devices PLC/Device ProtocolWire RS422 or RS485 Communications Configuring Port # 3 Passthrough Intermessage Time-OutData Configuration Use I/O DataUse Command Block Use DiagnosticsOutput Data Size Output DataInput Data Size Input DataOutput Data Table Use Output Word PLC/Device AddressFile Number Allen-Bradley PLCs only Register NumberInput Data Table Use Input Word PLC/DeviceAddressCommand Block DeviceNet to Motor Drives Devicenet to Motor DrivesDeviceNet Host to Serial Motor Drive DeviceNet Host to Multi-Dropped Serial Motor DrivesMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Configuring Port # 2 Motor Drives Motor Drive TypeMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Motor Drive Address Parameter NumberInput Data Table Use Input Word Word Motor Drive Address Command Number Word Parameter Data write command onlyWord Motor Drive Address Result Code Command Number Word Returned Parameter Data read command onlyUpper Link Configuration Mitsubishi Drives Only Operation of the Link SwitchException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesTransfer Options Download Project to DN3000Upload Project from DN3000 VerifySET Directory Options SettingsOptions Settings Current Directory Path Graphic Area SET COM Port Default Options SET Printer OptionsLoad Options from Disk Save Options to DiskTechnical Information Power RequirementsPhysical Dimensions Switch # Normal Off Configuration Diagnostic DIP Switch SettingsVisual LED Indicators Flashes followed by a pause DN-3000 Troubleshooting InformationFlashes followed by a pause Invalid DIP Switch Setting Registers Accessed Application Notes PLCs and DevicesALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Protocols SupportedLink Adapter Requirement Idec MICRO-3 PlcsIdec FA Series Plcs Memory Address PLC Registers Accessed Koyo / PLC Direct 205 Series PlcsKoyo / PLC Direct / TI 305 Series Plcs Mitsubishi FX Series Plcs Modicon Plcs and Modbus DevicesOmron Plcs RTS ControlProtocol Information Pass-Through PortSquare D Model 100-700 Plcs Passthrough Port NoteWestinghouse Plcs Toshiba EX and M Series PlcsToshiba T Series Plcs Drive Parameter Numbers Assigned By Panel-Tec Application Notes Motor DrivesBaldor Motor Drives Configuring a Baldor Drive For Serial Communications Drive Addresses Assigned By Panel-TecConfiguring a Woods Drive For Serial Communications Mitsubishi Motor DrivesWoods Motor Drives Yaskawa Motor DrivesCable Diagrams DN3000 Configuration CableAllen Bradley Solder EndGE Fanuc 90/20, 30 GE Fanuc DN3000Idec Koyo/PLC Direct Mitsubishi FX Series MitsubishiModicon ModiconOmron Host LinkSiemens S7 Square D TSX07Simatic TI5 Series TI5 232 Port DN3000Toshiba Toshiba DN3000Baldor Motor Drives BaldorMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet Cable DeviceNet DN3000