ICP DAS USA DN-3000, DB25, 100-700 PLCS user manual Input Data Size

Page 38

DeviceNet to Motor Drives

Input Data Size

This determines the number of words of Input data that will be used in your project. Input data is data that is input to your DeviceNet Host from the DN-3000 (command results, diagnostics information, and parameter data read from motor drives). This is also known as the Produced I/O Data of the DN-3000. If a Command Block is used, it will automatically reserve 3 words of Input data for command results. Similarly, if Diagnostics is used, it will automatically reserve 1 word of Input data. The combined size of Input and Output data must not exceed 32 words.

Input Data

Pressing the Input Data button brings up a window allowing you to edit the configuration of the Input data in your project. You can press the Input Data button by clicking on it with your mouse, or moving the focus to the button with the arrow keys and pressing the SPACEBAR. See “INPUT DATA TABLE CONFIGURATION”.

32

Image 38
Contents DN-3000 Page Warranty & Notices WarrantyTable of Contents Application Notes Motor Drives Page Introduction IntroductionGeneral Information Software InstallationInstallation Software Information Software START-UPCreating Project Files Creating a Project FileProject Types Additional Project Menu Sub-Headings Device Profile DeviceNet to PLCs or DevicesDevicenet to Plcs or Devices DeviceNet Host to Multi-Dropped Serial PLCs Example ApplicationsDeviceNet Host to Serial PLC with Pass-Through Connection Multiple DN-3000s with Different PLC or Device Types Configuring Port #1, Devicenet DeviceNet to PLCs or Devices Edit MenuMAC ID of DN3000 Configuring Port #2 Plcs or Devices PLC/Device ProtocolWire RS422 or RS485 Communications Configuring Port # 3 Passthrough Intermessage Time-OutData Configuration Use I/O DataOutput Data Size Use Command BlockUse Diagnostics Output DataInput Data Size Input DataOutput Data Table File Number Allen-Bradley PLCs only Use Output WordPLC/Device Address Register NumberInput Data Table Use Input Word PLC/DeviceAddressCommand Block DeviceNet to Motor Drives Devicenet to Motor DrivesDeviceNet Host to Serial Motor Drive DeviceNet Host to Multi-Dropped Serial Motor DrivesMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Configuring Port # 2 Motor Drives Motor Drive TypeMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Motor Drive Address Parameter NumberInput Data Table Use Input Word Word Motor Drive Address Result Code Command Word Motor Drive Address CommandNumber Word Parameter Data write command only Number Word Returned Parameter Data read command onlyUpper Link Configuration Mitsubishi Drives Only Operation of the Link SwitchException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesUpload Project from DN3000 Transfer OptionsDownload Project to DN3000 VerifySET Directory Options SettingsOptions Settings Current Directory Path Graphic Area SET COM Port Load Options from Disk Default OptionsSET Printer Options Save Options to DiskTechnical Information Power RequirementsPhysical Dimensions Switch # Normal Off Configuration Diagnostic DIP Switch SettingsVisual LED Indicators Flashes followed by a pause DN-3000 Troubleshooting InformationFlashes followed by a pause Invalid DIP Switch Setting ALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Registers AccessedApplication Notes PLCs and Devices Protocols SupportedLink Adapter Requirement Idec MICRO-3 PlcsIdec FA Series Plcs Memory Address PLC Registers Accessed Koyo / PLC Direct 205 Series PlcsKoyo / PLC Direct / TI 305 Series Plcs Omron Plcs Mitsubishi FX Series PlcsModicon Plcs and Modbus Devices RTS ControlProtocol Information Pass-Through PortSquare D Model 100-700 Plcs Passthrough Port NoteWestinghouse Plcs Toshiba EX and M Series PlcsToshiba T Series Plcs Drive Parameter Numbers Assigned By Panel-Tec Application Notes Motor DrivesBaldor Motor Drives Configuring a Baldor Drive For Serial Communications Drive Addresses Assigned By Panel-TecWoods Motor Drives Configuring a Woods Drive For Serial CommunicationsMitsubishi Motor Drives Yaskawa Motor DrivesCable Diagrams DN3000 Configuration CableAllen Bradley Solder EndGE Fanuc 90/20, 30 GE Fanuc DN3000Idec Koyo/PLC Direct Mitsubishi FX Series MitsubishiModicon ModiconOmron Host LinkSiemens S7 Square D TSX07Simatic TI5 Series TI5 232 Port DN3000Toshiba Toshiba DN3000Baldor Motor Drives BaldorMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet Cable DeviceNet DN3000