ICP DAS USA DB25, 100-700 PLCS, DN-3000 user manual Additional Project Menu Sub-Headings

Page 12

Creating Project Files

When the system returns to the “PROJECT’ menu, notice the additional sub-headings that were added to the “PROJECT” menu and are now available for you to use. A brief description of each of these new sub-headings are listed below:

Additional PROJECT

Menu Sub-Headings

CLOSE allows you to close a project file. More than one project file can be open at any time.

VIEW allows you to view; the project file name, project file type, and the current selections for each of the DN-3000’s serial ports.

SAVE allows you to save the current project file.

SAVE AS allows to save the current open project file under a different file name.

SWITCH TO allows you to switch between the opened project files. (Multiple files can be open.) PRINT allows you to print the project file’s configuration information.

GENERATE EDS FILE allows you to generate an EDS file for the current Project. The EDS file is used to tell a DeviceNet configuration tool information about the DN-3000 and I/O sizes. If you are using a DeviceNet configuration tool to set up your DeviceNet network, you should generate a new EDS file for each project.

Use the RIGHT arrow key to move the highlight bar from the top “PROJECT” header to the top “EDIT” header to proceed with editing the configuration information stored in the project file.

6

Image 12
Contents DN-3000 Page Warranty & Notices WarrantyTable of Contents Application Notes Motor Drives Page Introduction IntroductionSoftware Installation InstallationGeneral Information Software Information Software START-UPCreating Project Files Creating a Project FileProject Types Additional Project Menu Sub-Headings DeviceNet to PLCs or Devices Devicenet to Plcs or DevicesDevice Profile Example Applications DeviceNet Host to Serial PLC with Pass-Through ConnectionDeviceNet Host to Multi-Dropped Serial PLCs Multiple DN-3000s with Different PLC or Device Types Configuring Port #1, Devicenet DeviceNet to PLCs or Devices Edit MenuMAC ID of DN3000 Configuring Port #2 Plcs or Devices PLC/Device ProtocolWire RS422 or RS485 Communications Configuring Port # 3 Passthrough Intermessage Time-OutData Configuration Use I/O DataUse Command Block Use DiagnosticsOutput Data Size Output DataInput Data Size Input DataOutput Data Table Use Output Word PLC/Device AddressFile Number Allen-Bradley PLCs only Register NumberInput Data Table Use Input Word PLC/DeviceAddressCommand Block DeviceNet to Motor Drives Devicenet to Motor DrivesDeviceNet Host to Serial Motor Drive DeviceNet Host to Multi-Dropped Serial Motor DrivesMultiple DN-3000s with Different Motor Drive Types DeviceNet to Motor Drives Edit Menu MAC ID of DN3000 Configuring Port # 2 Motor Drives Motor Drive TypeMinimum Delay Between Messages Data Configuration Use Command Block Input Data Size Output Data Table Motor Drive Address Parameter NumberInput Data Table Use Input Word Word Motor Drive Address Command Number Word Parameter Data write command onlyWord Motor Drive Address Result Code Command Number Word Returned Parameter Data read command onlyUpper Link Configuration Mitsubishi Drives Only Operation of the Link SwitchException Table Mitsubishi Drives Only Transferring Project Files Transferring Project FilesTransfer Options Download Project to DN3000Upload Project from DN3000 VerifyOptions Settings Options SettingsSET Directory Current Directory Path Graphic Area SET COM Port Default Options SET Printer OptionsLoad Options from Disk Save Options to DiskPower Requirements Physical DimensionsTechnical Information DIP Switch Settings Visual LED IndicatorsSwitch # Normal Off Configuration Diagnostic DN-3000 Troubleshooting Information Flashes followed by a pause Invalid DIP Switch SettingFlashes followed by a pause Registers Accessed Application Notes PLCs and DevicesALLEN-BRADLEY PLC 5, SLC500 and Micrologix Plcs Protocols SupportedIdec MICRO-3 Plcs Idec FA Series PlcsLink Adapter Requirement Memory Address PLC Registers Accessed Koyo / PLC Direct 205 Series PlcsKoyo / PLC Direct / TI 305 Series Plcs Mitsubishi FX Series Plcs Modicon Plcs and Modbus DevicesOmron Plcs RTS ControlProtocol Information Pass-Through PortSquare D Model 100-700 Plcs Passthrough Port NoteToshiba EX and M Series Plcs Toshiba T Series PlcsWestinghouse Plcs Application Notes Motor Drives Baldor Motor DrivesDrive Parameter Numbers Assigned By Panel-Tec Configuring a Baldor Drive For Serial Communications Drive Addresses Assigned By Panel-TecConfiguring a Woods Drive For Serial Communications Mitsubishi Motor DrivesWoods Motor Drives Yaskawa Motor DrivesCable Diagrams DN3000 Configuration CableAllen Bradley Solder EndGE Fanuc 90/20, 30 GE Fanuc DN3000Idec Koyo/PLC Direct Mitsubishi FX Series MitsubishiModicon ModiconOmron Host LinkSiemens S7 Square D TSX07Simatic TI5 Series TI5 232 Port DN3000Toshiba Toshiba DN3000Baldor Motor Drives BaldorMitsubishi Motor Drives Woods Motor Drives Yaskawa Motor Drives DeviceNet Cable DeviceNet DN3000